Organizations: Institute of Unmanned System, Beihang University, Beijing 100191, China · School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China
Helically stranded cables in aerial towing systems experience oblique inflow, but are often modeled as smooth cylinders, neglecting three-dimensional cross-stream coupling and surface texture. We perform large-eddy simulations and spectral proper orthogonal decomposition for a smooth cylinder and four stranded cables at four inclinations from 22.5∘ to 90∘, all stationary, with Re≈1.0×104. Aerodynamic differences are governed mainly by cross-sectional symmetry and strand-scale groove depth. Force-source decomposition shows that surface pressure contributes 94.9%--98.3% of the mean normal force and dominates the mean lateral force. High-symmetry, quasi-circular envelopes maintain balanced circumferential pressure, whereas deep-grooved, low-symmetry tri-lobed geometries produce asymmetric separation and a persistent lateral pressure imbalance. In the wake, high-symmetry cables sustain spanwise-synchronized Karman shedding at moderate-to-high inclinations, concentrating fluctuation energy in a dominant low-rank mode. Deep grooves disrupt shedding coherence, deflect the recirculation zone laterally, and spread energy across broadband scales. Mean lateral force and lateral-force fluctuations are therefore decoupled: the quasi-circular (1×19) cable has minimal mean lateral force but strong periodic fluctuations, while the deep-grooved (3×7) cable has weak fluctuations but appreciable mean lateral force. These results support construction-dependent cable selection and aerodynamic load modeling.
Figures & tables
Figure 1: Schematic of an aerial towed system.
Figure 2: Nominal cable cross sections and representative stranded geometries, with cable-fixed coordinates and inflow velocity components: (a) cross-sectional contours of the five configurations; (b) single-strand 1×7 cable (Z lay); and (c) multi-strand 3×7 cable (Z/S lay).
Figure 3: Computational domain, coordinate system, and boundary conditions.
Figure 4: Mesh of the 1×7 cable: (a) surface mesh on the cable wall; and (b) volume-mesh cross section in the z=0 plane, with the coarse (upper half) and finest (lower half) meshes.
Case
Setting
Cn
Cℓ,rms
Stn
−Umin/Un
Lr/D
−Cpb
Grid sensitivity
Cylinder
coarse
1.215
0.478
0.201
0.277
0.92
1.238
medium
1.135
0.324
0.203
0.322
1.03
1.117
fine
1.090
0.275
0.210
0.306
1.22
1.054
finest
1.069
0.268
0.207
0.306
1.20
1.022
1×7 cable
coarse
1.122
0.219
0.198
0.294
1.14
1.053
Table 1: Grid and time-step sensitivity and reference results at 90∘ inflow.
Figure 5: Time-averaged surface-pressure distributions at α=90∘ : (a) smooth cylinder and (b) 1×7 cable on the four meshes; (c) smooth cylinder and (d) 1×7 cable for the three time steps on the fine mesh. The angle ϕs is measured from the windward stagnation line. The black dashed line is digitized from Norberg [ 54 ] at Re=8.0×103 , and the star marks the measured base pressure at Re=1.01×104 .
Figure 6: Detailed aerodynamic parameters for all 20 cases: (a) mean normal-force coefficient under total-speed normalization Cn(qtot) ; (b) mean normal-force coefficient under normal-speed normalization Cn(qn) ; (c) mean lateral-force coefficient Cℓ(qtot) ; (d) root-mean-square lateral-force fluctuation Cℓ,rms(qtot) ; (e) mean tangential-force coefficient Ct(qtot) ; and (f) absolute pressure share of the mean normal force.
Figure 7: Signed pressure and viscous force contributions across normal, lateral, and tangential directions for the 1×19 and 3×7 cables at α=67.5∘ .
Figure 9: Axial phase organization of the mean surface-pressure coefficient Cp(qtot) across the smooth cylinder and stranded cables at α=45∘ and 67.5∘ . Unwrapped horizontal coordinates ϕs∈[0∘,360∘] trace the circumferential envelope, and the vertical span z/D∈[−3,3] covers one lay pitch ( Lz=6D ). Solid and dashed lines mark the inter-strand and inter-wire grooves, respectively.
Figure 10: Mean-wake indicators across all 20 cases: (a) centerline minimum normal velocity Umin/Un ; (b) recirculation length Lr/D ; (c) integrated sectional velocity deficit D2 at x/D=2 ; (d) transverse wake deficit-center displacement yc/D at x/D=2 ; (e) wake width W2σ/D based on twice the deficit standard deviation at x/D=2 ; and (f) deficit profile skewness γ1 at x/D=2 .
Figure 11: Relative range δQ [Eq. ( 19 )] across axial sections of four wake indicators against inflow inclination: (a) recirculation length Lr/D ; (b) velocity deficit integral Idef ; (c) plane-averaged resolved turbulent kinetic energy kres/Un2 ; and (d) near-wake-averaged lateral velocity magnitude ∣uℓ∣/Un . Each range is the maximum-minus-minimum difference divided by the absolute value of the arithmetic mean across the axial sections, reported as a percentage.
Figure 12: Directional velocity fluctuations and area-weighted turbulent stresses across representative stranded cables and inclinations: (a)–(c) local lateral velocity variance Rℓℓ/Un2 at x/D=2 ; (d)–(f) local tangential velocity variance Rtt/Un2 at x/D=2 ; and (g)–(i) plane-averaged diagonal components 103Rii/Un2 ( i=n,ℓ,t ; no summation) across axial sections.
Figure 13: Cross-sectional distributions of the mean velocity field across six axial phase sections of the 3×7 stranded cable at α=67.5∘ : (a)–(f) normalized normal velocity un/Un and (g)–(l) normalized lateral velocity uℓ/Un . Subplot titles indicate the normalized axial position z/D .
Figure 14: Axial phase-to-phase spread distributions, ΔQ(x,y)=maxpQp(x,y)−minpQp(x,y) , across four representative stranded cable cases: (a)–(d) normal velocity spread Δun/Un ; (e)–(h) lateral velocity spread Δuℓ/Un ; and (i)–(l) resolved turbulent kinetic energy spread Δkres/Un2 .
Figure 15: Unsteady lateral aerodynamic forces and spectral characteristics across cable configurations and inclinations: (a) root-mean-square lateral-force coefficient Cℓ,rms(qn) ; (b) dominant vortex shedding frequency (peak Strouhal number) Stp ; (c) area-normalized lateral-force spectra Sℓ(Stn) comparing 3×7 and 1×19 cables at α=67.5∘ ; and (d) spectral evolution of the 3×7 cable across all four inclinations α=22.5∘–90∘ .
Figure 16: Spectral energy concentration and downstream force–wake association: (a) peak-neighborhood energy fraction ηp across inflow inclinations; (b) downstream magnitude-squared coherence γCℓ,uℓ,j2 across all five geometries at α=67.5∘ ; (c) downstream coherence evolution of the 3×7 cable across all four inclinations; and (d) unwrapped downstream probe phase lag θCℓ,uℓ,j along the wake centerline for the smooth cylinder, 1×19 , and 3×7 cables at α=67.5∘ .
Figure 17: Modal diagnostics and aerodynamic force characteristics across representative cases at the primary wake frequency: (a) mean lateral-force coefficient Cℓ(qn) and centered root-mean-square Cℓ,rms(qn) ; (b) leading SPOD modal energy fraction r1 ; (c) first-half/second-half modal overlap OFL ; and (d) spanwise phase-MAC variation range across axial sections.
Figure 18: Leading SPOD lateral modal fields at the primary wake frequency across representative cases: (a)–(d) real part Re(ψℓ) , showing the phase-aligned coherent structures; (e)–(h) modal envelope magnitude ∣ψℓ∣ , showing the distribution of normalized modal amplitude. The black outline traces the actual cable surface envelope.
This work proposes a framework that generates and optimally selects task-specific assembly configurations for a large group of homogeneous modular aerial systems, explicitly enforcing bounds on inter-module downwash. Prior work largely focuses on planar layouts and often ignores aerodynamic interference. In contrast, firstly we enumerate non-isomorphic connection topologies at scale; secondly, we solve a nonlinear program to check feasibility and select the configuration that minimizes control input subject to actuation limits and downwash constraints. We evaluate the framework in physics-based simulation and demonstrate it in real-world experiments.
Mengguang Li, Heinz Koeppl
Department of Electrical Engineering and Information Technology, Technische Universität Darmstadt, 64287 Darmstadt, Germany.
Multiple UAVs can cooperatively transport heavy payloads while controlling their position and orientation. Trajectory-based methods offer high agility while satisfying system constraints, but can produce uneven force distributions when the tension-to-wrench allocation is redundant or ill-conditioned, particularly under geometric mismatch and low-level tracking errors. We propose a hybrid planning-and-control framework to address this problem. A global planner generates payload trajectories and cable-force references by exploring the allocation null space under a prescribed internal-force setting. These references augment the cost of a centralized local planner, promoting feasible force distributions while generating trajectories for all UAVs. An admittance filter then compares the planned forces with onboard cable-tension estimates and adjusts the kinematic references to improve force tracking in degenerate or near-degenerate configurations. Simulations and experiments involving four to ten UAVs demonstrate more balanced tension distributions during both hovering and demanding agile maneuvers, without compromising agility or payload-tracking performance.
Antreas Kourris, Sihao Sun
Faculty of Mechanical Engineering, Delft University of Technology
Learned simulators for deformable linear objects (DLOs) such as cables have to predict the motion of cables they were not trained on and stay stable over long rollouts. Most of their error occurs where the cable touches itself or the floor. Attention over all pairs of cable segments can represent contact between parts of the cable that are far apart along its length, but attention has no notion of geometry. A cable has two pairwise distances, which agree only while it is straight: the arc-length distance along the cable, which governs elastic forces, and the Euclidean distance in space, which governs contact. We add a physical attention bias, an additive term on the attention logits with a learned rate, and ask which distance it should use. We compare no bias, each distance alone, and both distances on disjoint sets of heads, keeping the rest of the model and the training protocol fixed. A physical bias improves prediction on unseen cables. The gain is largest when attention is the only mechanism that connects distant segments: there, the arc-length bias reduces prediction error by 15% and more than halves the drift in segment length. The Euclidean bias alone stays close to unbiased attention, while assigning both distances across heads is best or near-best on every metric we report. Code and per-run records: https://github.com/avihaig/dlogps.