cs.RONov 9, 2026

Design of a hybrid tendon-linkage finger with coupled and adaptive motion

Authors: Hyojae Kang, Giup Seo, Jae-Young Lee, Yeong Jae Park, Jongwoo Park, Hyunmin Do, So-Hee Park, Dongil Park, 

Organizations: Advanced Robotics Research Center, Korea Institute of Machinery & Materials (KIMM) · Mechanical Engineering, University of Science & Technology (UST)

Abstract

Dexterous robotic fingers require coordinated joint motion and adaptability to object contact, while independently actuating multiple joints increases the complexity of the transmission mechanism. This paper presents a hybrid tendon--linkage robotic finger with four mechanical degrees of freedom driven by three actuators. The MCP abduction/adduction joint is driven through a bevel gear, while MCP and PIP flexion/extension are driven by separate bidirectional tendon transmissions. The DIP joint is not independently actuated but is coupled to the PIP joint through a four-bar linkage with a torsional spring and mechanical stopper. The tendon routing also introduces mechanical coupling between the MCP and PIP joints. Kinematic analysis was conducted to describe the coupled and adaptive motions, and experiments were performed to evaluate the joint motion characteristics. ArUco-based measurements showed that the coupled motion closely matched the theoretical prediction, whereas the adaptive motion was partially limited by interference between linkage components. The fabricated finger demonstrated different contact postures with cylindrical, cuboid, and irregularly shaped objects, and the mean peak fingertip force was 4.56 N. The proposed mechanism provides both coupled motion and contact-dependent adaptation without requiring an additional actuator for the DIP joint.

Figures & tables

Explore similar work

Oct 7, 2026

Design of a Fully Actuated 4-DOF Robotic Finger With Joint-Specific Hybrid Remote Actuation

This paper presents a fully actuated 4-DOF robotic finger using a joint-specific hybrid remote-actuation architecture. The metacarpophalangeal (MCP) joint is driven by two coordinated rigid-link transmission sets, whereas the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints are independently actuated by closed-loop wire transmissions incorporating circular rolling-contact joints (RCJs). A larger transmission radius is used at the PIP joint than at the DIP joint. The RCJ wire geometry maintains the total wire-loop length during joint rotation, and the DIP wire routing is designed so that PIP motion does not affect its differential actuation for a fixed MCP configuration. The distal wire transmission, MCP linkage, and fingertip kinematics are analytically modeled. In experiments, the transmission behavior was quantitatively evaluated from the ball-screw displacements measured using ArUco-marker tracking. MCP actuation produced measurable displacements of the PIP and DIP transmission units, whereas isolated PIP and DIP actuation with the MCP fixed supported the intended mechanical decoupling between the distal transmissions. The mean peak fingertip forces under isolated MCP, PIP, and DIP actuation were 21.28 N, 9.22 N, and 5.75 N, respectively. The resulting finger postures were also examined using objects of different geometries and sizes.
Oct 27, 2026

A fully articulated humanoid dexterous hand with human-level joint structure enabled by linkage-based actuation

Humanoid dexterous hands are a core component of embodied intelligence, enabling robots to translate high-level intent into rich and adaptive physical interaction. However, existing designs remain constrained by a persistent trade-off among anthropomorphic kinematic complexity, mechanical robustness, load capacity and control simplicity, limiting dexterous manipulation in unstructured environments. Here we present Torch-Hand, a fully articulated humanoid dexterous hand that replicates the joint structure and motion hierarchy of the human hand with 21 degrees of freedom (DOF), comprising a highly articulated five-DOF thumb and four DOF in each of the remaining fingers. The differentiated thumb integrates multi-axis CMC motion to provide broad opposition and flexible contact orientation relative to the four fingers. Unlike tendon-driven or hybrid actuation approaches, Torch-Hand adopts an entirely linkage-based transmission architecture. By integrating screw-linkage actuation, the hand achieves high grasping force and substantial payload capacity while maintaining a compact anthropomorphic form. Its actuation architecture is optimized for control tractability, with all actuators integrated within the palm and arranged in a serial-robot-like configuration that establishes a direct correspondence between motor motion and joint kinematics. This architecture mechanically decouples functional DOF to reduce unintended inter-joint motion propagation, while allowing independently addressable DOF to be actively coordinated into coupled multi-joint motion patterns during complex manipulation. Comprehensive experiments assess reachable workspace, coordinated fingertip trajectories, thumb opposition, 33-grasp taxonomy coverage, grasping force, payload capacity and task-level manipulation. These results establish Torch-Hand as a robust hardware foundation for dexterous embodied manipulation.
Sep 1, 2026

A Compact Robotic Finger with 2-DoF MCP Joint Embedding DoF-Selective Passive Continuously Variable Transmission for Wide Force-Speed Operating Range

This letter presents a compact two-degree-of-freedom (DoF) robotic finger with a flexion-selective passive continuously variable transmission (CVT) to achieve a wide force-speed operating range. Inspired by the functional differentiation of the human metacarpophalangeal (MCP) joint, the proposed mechanism realizes DoF-specific transmission differentiation by selectively assigning passive CVT to the flexion-extension DoF while preserving direct transmission for abduction-adduction. For a wide force-speed operating range, a force-responsive passive CVT is embedded in the flexion pathway, while direct transmission is preserved for the abduction-adduction pathway. To selectively realize transmission adaptation within a multi-DoF MCP mechanism, an output-side passive CVT employing a moving-pulley-inspired wire-routing structure is introduced. The resultant force generated by the wire tensions acting on the pulley that passively increases the flexion moment arm and transmission ratio according to the applied load without additional actuators, sensors, or control. Experimental results demonstrate a maximum output-force amplification of 4.19-fold and a mean amplification of 3.6-fold across the tested flexion angles ranging from 15 degrees to 75 degrees through moment-arm adaptation, thereby substantially expanding the achievable force-speed operating range. Furthermore, dexterous ball-rolling experiments verify that passive transmission adaptation can be achieved while preserving abduction-adduction functionality. These results demonstrate a scalable transmission design strategy for compact multi-DoF robotic hands.