Design of a hybrid tendon-linkage finger with coupled and adaptive motion
Authors: Hyojae Kang, Giup Seo, Jae-Young Lee, Yeong Jae Park, Jongwoo Park, Hyunmin Do, So-Hee Park, Dongil Park, Jeongdo Ahn
Organizations: Advanced Robotics Research Center, Korea Institute of Machinery & Materials (KIMM) · Mechanical Engineering, University of Science & Technology (UST)
Dexterous robotic fingers require coordinated joint motion and adaptability to object contact, while independently actuating multiple joints increases the complexity of the transmission mechanism. This paper presents a hybrid tendon--linkage robotic finger with four mechanical degrees of freedom driven by three actuators. The MCP abduction/adduction joint is driven through a bevel gear, while MCP and PIP flexion/extension are driven by separate bidirectional tendon transmissions. The DIP joint is not independently actuated but is coupled to the PIP joint through a four-bar linkage with a torsional spring and mechanical stopper. The tendon routing also introduces mechanical coupling between the MCP and PIP joints. Kinematic analysis was conducted to describe the coupled and adaptive motions, and experiments were performed to evaluate the joint motion characteristics. ArUco-based measurements showed that the coupled motion closely matched the theoretical prediction, whereas the adaptive motion was partially limited by interference between linkage components. The fabricated finger demonstrated different contact postures with cylindrical, cuboid, and irregularly shaped objects, and the mean peak fingertip force was 4.56 N. The proposed mechanism provides both coupled motion and contact-dependent adaptation without requiring an additional actuator for the DIP joint.
Actuated MCP/PIP motion with coupled PIP–DIP motion
Tendon-driven self-adaptive mode
Table 1: Comparison of representative coupled and adaptive robotic finger mechanisms.
Figure 1: Overall structure of the proposed robotic finger: (a) specification, (b) joint and phalanx configuration, and (c) internal transmission components with detailed views.
Figure 2: Tendon-routing paths and joint rotations induced by ball-screw actuation: (a) MCP F/E transmission and (b) PIP F/E transmission.
Figure 3: (a) Serial kinematic chain and coordinate frames, and (b) planar flexion transmission showing the MCP and PIP tendon displacements qM and qP and the distal coupled–adaptive linkage.
Figure 4: Reachable fingertip workspace during unconstrained motion.
i
ai−1
αi−1
di
qi
1
a0
0
0
θ1
2
a1
π/2
0
θ2−θ23
3
a2
0
0
θ3+θ23
4
a3
0
0
θ4
5
a4
0
0
0
Table 2: Denavit–Hartenberg Parameters of the Finger.
θ1
θ2
θ3
θ4 (Coupled)
−π/6 to π/6
−π/2 to 0
−π/2 to 0
−3π/20 to 0
Table 3: Range of Motion of the Finger Joints.
Symbol
Description
Value
rM
Radius of MCP driven pulley
6.00 mm
rP
Radius of PIP driven pulley
4.00 mm
L12
Length of link L12
17.18 mm
L23
Length of link L23
8.00 mm
L34
Length of link L34
5.80 mm
L54
Length of link L54
20.00 mm
Table 4: Design Parameters of the Proposed Finger.
Specification
Proposed finger
DoF 1
4
DoA 2
3
Motion
MCP A/A & F/E, PIP F/E, DIP F/E
Fingertip force
4.56 N
Backdrivable
No
Weight
193.6 g
Table 5: Technical specifications.
Figure 5: Four types of the motions of fabricated finger.
Figure 6: Coupled and adaptive PIP–DIP motion characteristics.
Figure 7: Experimental setup and measurement results of fingertip force.
Figure 8: Postures of the finger during interaction with various objects.