Ground Reaction Force-Aware Model Predictive Control for Underactuated Upright Physical Assistance
Authors: Darren Biskup, Jeonghan Yu, Zibo Yu, Sunil K. Agrawal
Organizations: Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA. · Department of Mechanical Engineering, SUNY Korea, Incheon 21985, Republic of Korea. · Department of Rehabilitation and Regenerative Medicine, Columbia University, New York, NY 10027, USA.
Many rehabilitation robots execute prescribed motions using reactive tracking controllers that do not explicitly incorporate the user's instantaneous human-ground interaction. This paper presents Ground Reaction Force-Aware Model Predictive Control (GRF-MPC), a framework for upright physical assistance. By integrating live GRF and center of pressure (CoP) measurements directly into a human centroidal dynamics model, GRF-MPC formulates a real-time quadratic program (QP) that optimizes assistive forces and moments over a receding horizon. We deployed GRF-MPC on the Robotic Upright Stand Trainer (RobUST) in an underactuated 4-cable configuration and evaluated it against a fully actuated 8-cable Cartesian impedance baseline in nearly 300 trials across six healthy participants. Across tasks spanning impulsive perturbations, lunge trajectories, and voluntary limits of stability, GRF-MPC reduced peak planar center-of-mass (CoM) error by 19.6% during perturbations, lowered trajectory tracking error by 24.1%, required 28.7% less net mechanical work, and permitted a 45.9% greater normalized voluntary excursion area. The underlying QP solves in under 1 ms, comfortably enabling 100 Hz replanning and demonstrating that incorporating live human-ground interaction into predictive control yields stronger, more transparent physical assistance with half the actuators.
Figures & tables
Fig. 1: (A) Schematic of the Robotic Upright Stand Trainer (RobUST) system highlighting motion tracking, cable actuation, and CoP/GRF measurement. (B) Photograph of the experimental setup showing the user equipped with Vive trackers, standing on force plates, and receiving visual feedback. (C) Real-time graphical interface displaying the user’s inertia ellipsoid, target and predicted positions, and force vectors.
Fig. 2: Hierarchical control architecture for GRF-MPC on RobUST. The high-level controller implemented in C# uses tracker and force plate data to solve the convex QP problem in real-time. The resulting optimal tension commands are transmitted asynchronously to the low-level NI PXIe system, which tracks the tension via load cell feedback.
Parameter
Value
4-Cable GRF-MPC
N (prediction horizon)
10 steps
Δt (discretization)
0.05 s
Qx,y
500
Qz
100
Qp˙
50
TABLE I: Controller Parameters
Fig. 3: (A) Illustration of the fully actuated impedance control baseline, contrasted with the underactuated 4-cable GRF-MPC. (B) Illustration of experimental tasks: Stable Standing under perturbation (left); Deep Lunge tracking (middle); and Permitted Workspace Mapping via voluntary chest displacement (right).
Fig. 4: Representative perturbation response for a single subject. (Top) Planar CoM position vs. time under Transparent, Impedance, and MPC conditions. (Bottom) Planar CoP excursion measured by the force plates during the same trial.
Fig. 5: Experimental results across all three tasks. Error bars indicate Standard Deviation. (A) Task 1: Standing Perturbation — comparison of peak planar CoM error (top) and settling decay time (bottom) for subjects S1–S6 under Transparent, Impedance, and MPC control modes. (B) Task 2: Lunge tracking efficiency — CoM planar error (top) and cumulative mechanical work (bottom). (C) Task 3: Permitted workspace mapping — normalized excursion area demonstrating the MPC’s ability to preserve a significantly larger functional workspace compared to rigid impedance control.
Department of Electrical and Computer Engineering, National University of Singapore, Singapore 119077, Singapore · Department of Mechanical Engineering, National University of Singapore, Singapore 119077, Singapore