cs.CVNov 9, 2026

Domain adaptation of a video Foundation model for Heart Failure Diagnosis from Echocardiography

Authors: Mahyar Bolhassani, Tijana Geroski, Narayana S. Singam, Amir Amini

Organizations: Department of Electrical and Computer Engineering, University of Louisville, Louisville, KY · Faculty of Engineering, University of Kragujevac, Kragujevac, Serbia

Abstract

The rapid advancement of foundation models has transformed computer vision, yet their adaptation to medical imaging, particularly purpose built foundation models for spatio temporal echocardiography videos, remains limited. In this work, we explore the feasibility of fine tuning a pretrained foundation model for video (TimeSformer) for automated diagnosis of reduced ejection fraction heart failure (HFrEF) from apical four chamber videos. The model is finetuned on the publicly available RVENet A4C dataset with a phase aware clip generation strategy that captures complementary systolic and diastolic dynamics. We employ divided space time attention, layer wise learning rate decay, and multi clip inference to enhance robustness under limited data. Experimental results show that full fine tuning of the proposed model outperforms classifier only tuning and a 3D CNN baseline. These findings highlight the potential of leveraging foundation video models for echocardiography based heart failure diagnosis and motivates further domain adaptation studies in medical imaging.

Explore similar work

Apr 25, 2026

Domain-Adapted Fine-Tuning of ECG Foundation Models for Multi-Label Structural Heart Disease Screening

Transthoracic echocardiography is the reference standard for confirming structural heart disease (SHD), but first-line screening is limited by cost, workflow burden, and specialist availability. We evaluated whether open pretrained electrocardiogram (ECG) foundation models can support echo-confirmed multi-label SHD detection using the public EchoNext Mini-Model benchmark. Six echocardiography-derived abnormalities were targeted: reduced left ventricular ejection fraction, increased left ventricular wall thickness, aortic stenosis, mitral regurgitation, tricuspid regurgitation, and right ventricular systolic dysfunction. Under a common pipeline, we compared engineered ECG features with gradient boosting, end-to-end waveform learning from scratch, and transfer from open ECG foundation models. We then applied in-domain self-supervised adaptation of an ECG foundation model (ECG-FM) on EchoNext waveforms followed by selective supervised fine-tuning, and evaluated trade-offs between discrimination and adaptation cost. Adapted ECG-FM models achieved the best overall performance: peak macro-AUROC 0.8509 and macro-AUPRC 0.4297, while a parameter-efficient operating point preserved AUROC (0.8501) and attained the highest fixed-threshold macro-F1 0.3691. Late fusion with covariates did not improve threshold-independent discrimination, and evaluated LoRA, alternative backbones, and mixture-of-foundations strategies did not surpass the best adapted single-backbone models. These results indicate that for ECG-based case finding and echocardiography triage, combining target-domain self-supervised adaptation with selective supervised updating of a pretrained ECG backbone is the most effective transfer strategy.
Nov 20, 2026

EchoAlign: Echocardiography foundation model with multilevel report alignment

Echocardiography assesses the structure and function of the heart. Cardiologists read each study across several standard views and report the findings visible in those views by cardiac structure. AI foundation models can learn to analyze these studies from clinical reports, reducing annotation burden and supporting clinical interpretation. However, existing models are trained by pairing each video with the full clinical report, including structures and findings its view does not show. This mismatch lets a model associate a finding with incidental or spurious signals rather than its visual evidence, which limits accuracy, anatomical grounding and clinical trust. Here we introduce EchoAlign, a vision-language foundation model developed on 2.87 million echocardiographic videos and images from 159 clinical centers. EchoAlign aligns each cardiac structure, video and study with its report text, and a visibility matrix restricts supervision to the views that actually depict each structure. We compare it with five public foundation models on 0.47 million test videos across ten unseen external datasets from more than 25 clinical centers. EchoAlign achieves the highest mean AUROC of 0.890 (95% CI, 0.881 to 0.897) for classification and the highest mean quadratic weighted kappa of 0.530 (95% CI, 0.511 to 0.544) for severity grading. Across 62 clinical findings, EchoAlign provides one model that detects findings, grades their severity, estimates measurements and segments cardiac structures.
Nov 13, 2026

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.