cs.AINov 9, 2026

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

Authors: Juan Liu, Nian Wang

Organizations: Advanced Imaging Research Center, University of Texas Southwestern Medical Center, USA · Department of Biomedical Engineering, University of Texas Southwestern Medical Center, USA · Peter O’Donnell Jr. Brain Institute, University of Texas Southwestern Medical Center, USA

Abstract

Purpose: To develop a phase-aware self-supervised framework for accelerated high-resolution multi-echo gradient-echo (mGRE) MRI that preserves anatomical detail and complex echo information for quantitative mapping. Methods: We developed multi-stage phase-aware self-supervised reconstruction (MSPR-GRE), integrating progressive k-space expansion with phase estimation and refinement. Sequential unrolled networks reconstruct complex multi-echo images and update echo-dependent phase priors. A relaxation-informed temporal subspace is used for acquisitions with at least four echoes, while shorter echo trains are reconstructed in the image domain. Training uses held-out acquired k-space samples without fully sampled targets. Evaluation included 9.4 T ex vivo mouse-brain data 30um eight-echo and 18um dual-echo) and retrospectively undersampled 7 T AHEAD human-brain data, with supervised ablations. Results:MSPR-GRE reduced artifacts in regions of rapid phase variation and preserved fine mouse-brain anatomy. Across five AHEAD test datasets at R = 4, 8, and 12, it generally improved magnitude-image, T2* map, and QSM metrics, particularly at higher acceleration. At R = 12, fourth-echo magnitude NRMSE was 12.09±\pm0.60% versus 21.55±\pm1.12% for SSDU. Ablations indicated benefits of phase refinement, while supervised experiments supported multi-stage phase-aware reconstruction. Conclusion: MSPR-GRE improves accelerated mGRE reconstruction and quantitative-map agreement without fully sampled training targets. Further validation of generalizability and phase-estimation accuracy is needed.

Figures & tables

Explore similar work

Sep 21, 2026

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.
Oct 20, 2026

AGGR-Mamba: Mamba-based Network with Attention-Guided Gated Residual Refinement for Undersampled MRI Reconstruction

Undersampled magnetic resonance imaging (MRI) reconstruction aims to recover high-quality images from partially acquired k-space data, thereby reducing scan time. However, missing frequency-domain measurements often lead to residual aliasing artifacts, blurred edges, and loss of local structural details. In this paper, we propose AGGR-Mamba, a lightweight output-stage residual refinement method built upon a Mamba backbone for undersampled brain MRI reconstruction. The Mamba backbone first produces an initial reconstruction, and the proposed refinement modules then correct the remaining local errors and high-frequency artifacts in a controlled residual manner. Specifically, an Attention Refine Head is introduced to recalibrate local anatomical structures, edge textures, and residual-error regions through channel and spatial attention. In addition, a GDFN-style gated residual refinement branch is designed to selectively preserve informative residual features while suppressing redundant or unstable responses. By combining attention-based recalibration with gated residual selection, AGGR-Mamba improves local structure recovery without substantially disturbing the backbone reconstruction. Experiments are conducted on the IXI brain MRI dataset with T1- and T2-weighted images under acceleration factors of R=4 and R=8. The results show that AGGR-Mamba achieves competitive PSNR and SSIM performance across different reconstruction settings, demonstrating the effectiveness of the proposed output-stage refinement strategy.
Aug 18, 2026

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors

MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose C+Mag\mathbb{C}+\text{Mag}, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.