cs.CVNov 10, 2026

Interleaving anatomical inspection and diagnostic reasoning for explainable radiology report generation

Authors: Chentao Huang, Runlong Lin, Zhijun Wang, Yunxiang Li, Yuanyuan Sun, Jian Wang, Hongfei Lin, Ling Luo

Organizations: School of Computer Science and Technology, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian, 116024, Liaoning, China. · Department of Nuclear Medicine, The Second Hospital of Dalian Medical University, No. 467 Zhongshan Road, Shahekou District, Dalian, 116023, Liaoning, China.

Abstract

Automated radiology report generation can draft clinically plausible reports, yet the pathway from visual evidence to reported findings remains opaque, leaving the diagnostic basis of these reports unexplained and the generated reports difficult to review or revise. We introduce ARIVE (Anatomy-guided Reasoning with Interleaved Visual Evidence), an explainable report generation framework that interleaves anatomical inspection with diagnostic reasoning prior to final report composition. To support this process, we constructed 159,416 multimodal chain-of-thought (MCoT) trajectories from MIMIC-CXR, wherein visual evidence from inspected anatomical regions informs subsequent clinical interpretation. Trained on these trajectories and further optimized using anatomical and clinical-content rewards, ARIVE achieved superior clinical-efficacy performance compared with strong baselines on MIMIC-CXR and the abnormality-centered MIMIC-ABN. ARIVE's reports were competitive with those of leading models in blinded expert grading, and its MCoT trajectories earned high ratings for diagnostic traceability. Furthermore, a paired review evaluation suggests that access to MCoT can aid in identifying errors within generated reports.

Figures & tables

Appendix figures & tables10 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Nov 1, 2026

AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation

Radiology report generation (RRG) streamlines clinical workflows and alleviates the burden of radiologists' documentation. Standard vision-language models capture global visual cues and lack fine-grained alignment between anatomical regions and diagnostic text. Most retrieval-augmented methods retrieve complete historical reports, introducing redundant noise and severe vision-text mismatches that trigger clinically risky hallucinations and missed lesions. In this paper, we introduce AR-RRG, an anatomy-guided retrieval-driven method for the generation of radiology reports. AR-RRG consists of two core modules: the anatomy-aware self-training lesion detection network (ASLDNet) and the retrieval-driven radiology report generation (RRRG). ASLDNet leverages anatomy-aware spatial verification (ASV) and class-adaptive dynamic thresholding (CDT) via self-training, delivering accurate lesion localization to support subsequent generation. As the generative branch of AR-RRG, RRRG eliminates clinical hallucinations through dual-granularity retrieval (DR) and complements missing lesions with a neighborhood consensus (NC) mechanism. A parallel continuous visual perception (PCVP) stream converts radiographs into visual tokens through fixed medical encoding and resampling. Multi-scale text and visual features are fused, followed by LoRA-efficient large language model tuning to generate clinically consistent, visually grounded radiology reports. Extensive evaluations on MS-CXR, MIMIC-CXR, and IU X-Ray demonstrate that AR-RRG consistently outperforms state-of-the-art methods across mainstream metrics. Our code will be made publicly available.
Mar 14, 2026

EviAgent: Evidence-Driven Agent for Radiology Report Generation

Automated radiology report generation holds immense potential to alleviate the heavy workload of radiologists. Despite the formidable vision-language capabilities of recent Multimodal Large Language Models (MLLMs), their clinical deployment is severely constrained by inherent limitations: their "black-box" decision-making renders the generated reports untraceable due to the lack of explicit visual evidence to support the diagnosis, and they struggle to access external domain knowledge. To address these challenges, we propose the Evidence-driven Radiology Report Generation Agent (EviAgent). Unlike opaque end-to-end paradigms, EviAgent coordinates a transparent reasoning trajectory by breaking down the complex generation process into granular operational units. We integrate multi-dimensional visual experts and retrieval mechanisms as external support modules, endowing the system with explicit visual evidence and high-quality clinical priors. Extensive experiments on MIMIC-CXR, CheXpert Plus, and IU-Xray datasets demonstrate that EviAgent outperforms both large-scale generalist models and specialized medical models, providing a robust and trustworthy solution for automated radiology report generation.
Nov 12, 2026

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.