Abstract

Respiratory and bulk motion displace the spinal cord between the volumes of a functional MRI time series. Current methods such as the Spinal Cord Toolbox (SCT) take several minutes per time series, and general-purpose brain tools register whole volumes, whereas the cord moves mainly slice by slice. We propose a lightweight convolutional neural network that regresses the in-plane translation aligning each axial slice to a reference. Two models, trained without motion labels, correct large and then residual motion. On a 3T (120 scans) and a 7T (59 scans) dataset, the proposed method improves on SCT on every metric (tSNR +10 to +25%, DVARS -20 to -38%), leaves almost no slice displaced by more than one voxel (<0.1%), performs on par with a slice-wise AFNI variant and better than slice-wise FSL FLIRT, and runs in about 10 s per scan, about 30 times faster than SCT. The code is available at https://github.com/ivadomed/moco-dl and the method is available in SCT v7.4.

Figures & tables

Explore similar work

Sep 21, 2024

A Unified Deep Learning Framework for Motion Correction in Medical Imaging

Deep learning has shown significant value in medical image registration for motion correction; however, current techniques are either limited by the type and range of motion they can handle or require iterative inference and/or retraining for new imaging data. To address these limitations, we introduce UniMo, a Unified Motion Correction framework that uses deep neural networks to correct various types of motion in medical imaging. UniMo uses an alternating optimization scheme with a unified loss function to train an integrated model of 1) an equivariant neural network for global rigid motion correction and 2) an encoder-decoder network for local deformations. It features a geometric deformation augmenter that 1) enhances the robustness of global motion correction by addressing local deformations, whether caused by non-rigid motion or geometric distortions, and 2) generates augmented data to improve training. As a hybrid model that uses both image intensities and shapes, UniMo is robust to appearance variations and generalizes to various imaging modalities without retraining. We trained and tested UniMo for motion tracking in fetal magnetic resonance imaging, which is challenging due to 1) both large rigid and non-rigid motion and 2) large variations in image appearance. We then tested the trained model, without retraining, on three public datasets: MedMNIST, lung CT, and BraTS. UniMo surpassed existing motion correction methods in accuracy and, notably, enabled one-time training on a single modality while maintaining high stability and adaptability across multiple unseen imaging datasets. By offering a unified solution to motion correction, UniMo marks a significant advance in challenging applications with a mixture of bulk motion and local deformations. Code is available at https://github.com/IntelligentImaging/UNIMO
May 29, 2026

Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts

Motion artifacts in magnetic resonance imaging (MRI) degrade diagnostic reliability. Existing deep learning methods are typically contrast-specific and fail to generalize across diverse modalities and artifact severities. We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction. ScanCLIP, pretrained on over 30,000 MRI text-image pairs, derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features. A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction. A dual-pathway decoder reconstructs both the clean image and residual artifact map, enforcing image-space consistency. On IXI and HCP benchmarks, our method improves PSNR by 0.75 dB and SSIM by up to 0.0279 over state-of-the-art approaches, with larger gains at higher artifact severities. It further demonstrates robust zero-shot generalization on real-world clinical data acquired with unseen scanning parameters, where existing methods either fail to remove artifacts or introduce additional distortions.
Sep 21, 2026

GraphSVR: q-Space--Aware Graph-Based Slice-to-Volume Registration for Diffusion MRI

Diffusion-weighted imaging (DWI) remains highly vulnerable to subject motion, particularly in time-efficient protocols and in motion-prone populations. While slice-to-volume registration (SVR) can mitigate inter-slice and inter-stack misalignment, diffusion MRI introduces additional complexity due to diffusion-direction-dependent contrast and the requirement to align dozens of measurements within a common reference frame, effectively yielding a 4D registration problem. Existing approaches rely primarily on sequential modeling or pairwise similarity and often degrade under sparse gradient sampling or severe motion. We introduce GraphSVR, a q-space-aware graph-based framework for 4D SVR registration in DWI. GraphSVR represents slice groups as nodes in an acquisition-structured graph, with edges encoding temporal proximity, spatial slice geometry and diffusion encoding relationships. A graph neural network predicts globally consistent stack-wise rigid motion, optimized in a self-supervised, zero-shot manner using only an anatomical reference image, without requiring paired ground-truth motion. We evaluate GraphSVR using both fully synthetic diffusion simulations and realistic recombination-based simulations from real acquisitions with controllable motion severity and gradient sparsity. Performance is quantified using grid error (mm) and rotation error relative to known ground-truth transforms. Under severe motion, GraphSVR reduces grid error and rotation error by 73% compared to FSL eddy, the standard DWI motion-correction method, with the largest gains observed in sparse-direction regimes. These results demonstrate that explicitly modeling acquisition structure through graph-based reasoning improves robustness and global consistency in 4D DWI motion estimation. Code is available at https://github.com/nogakertes/GraphSVR.git.