cs.AINov 11, 2026

A frontier machine intelligence for human neuroimaging

Authors: Chenhui Zhao, Akshay Rao, Akhil Kondepudi, Yiwei Lyu, Xinhai Hou, Rikhil Seshadri, Cheng Jiang, Soumyanil Banerjee, 

Organizations: Machine Learning in Neurosurgery Lab, University of Michigan · University of Michigan Computer Science and Engineering · University of Michigan Biomedical Engineering · University of Michigan Computational Medicine and Bioinformatics · 

Abstract

Medical imaging is essential for diagnosing disease, guiding treatment and monitoring patients over time. Although artificial intelligence has advanced image interpretation, existing medical models often address restricted tasks, while general-purpose proprietary models lack access to private clinical imaging required to achieve medical expertise. Developing models that can interpret complex examinations and communicate their findings in the context of clinical decisions remains a major challenge. Here, we show that Neuro-VL, a vision-language model trained on nearly one million neuroimaging studies from routine clinical care, can interpret complete imaging examinations and engage in natural language conversations about their findings. Across internal and international datasets, Neuro-VL outperformed frontier general-purpose and specialized medical models in diagnosing, localizing, and describing abnormalities, as well as generating comprehensive radiology reports. The model also compared serial examinations to assess disease progression and more reliably resisted misleading clinical assumptions than leading frontier models from OpenAI and Google. These results extend health system learning beyond individual predictions to interactive image interpretation and longitudinal disease monitoring. They demonstrate how the collective clinical experience of health systems can be used to develop medical AI with specialized expertise and broad clinical capabilities.

Figures & tables

Appendix figures & tables17 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Mar 30, 2026

Prompts Without Evidence: How Neuroimaging Mentions Shift Clinical Vision-Language Model Predictions

Trustworthy clinical AI must use real evidence and avoid relying on surface-level artifacts. We evaluate 12 open-weight vision-language models (VLMs) on two clinical neuroimaging cohorts for binary classification of affective disorders and cognitive decline. Both cohorts include structural magnetic resonance imaging (MRI) acquired under their original research protocols. Prior work does not establish the included neuroimaging inputs as reliable stand-alone diagnostic evidence for the present tasks. Nevertheless, when neuroimaging context is introduced, smaller VLMs gain up to 0.66 F1 under the evaluated augmented conditions, becoming competitive with models an order of magnitude larger. Confidence estimation shows that most of the calibration improvement for the analyzed smaller models occurs after the MRI reference is added to the prompt, before any image is supplied. Our preliminary expert case study finds that faithfulness remains low in every condition examined, with the reviewed model introducing unverified clinical details. Finally, in our single-model intervention, preference alignment suppresses MRI-referencing behavior but reduces the augmented-condition advantage, leaving the underlying issue unresolved. These results caution against reading surface metric gains as evidence of true multimodal integration, with direct implications for clinical VLM deployment.
Mar 25, 2026

RVLM: Recursive Vision-Language Models with Adaptive Depth

Medical AI systems face two fundamental limitations. First, conventional vision-language models (VLMs) perform single-pass inference, yielding black-box predictions that cannot be audited or explained in clinical terms. Second, iterative reasoning systems that expose intermediate steps rely on fixed iteration budgets wasting compute on simple cases while providing insufficient depth for complex ones. We address both limitations with a unified framework. RVLM replaces single-pass inference with an iterative generate-execute loop: at each step, the model writes Python code, invokes vision sub-agents, manipulates images, and accumulates evidence. Every diagnostic claim is grounded in executable code, satisfying auditability requirements of clinical AI governance frameworks. RRouter makes iteration depth adaptive: a lightweight controller predicts the optimal budget from task-complexity features, then monitors progress and terminates early when reasoning stalls. We evaluate on BraTS 2023 Meningioma (brain MRI) and MIMIC-CXR (chest X-ray) using Gemini 2.5 Flash without fine-tuning. Across repeated runs, RVLM shows high consistency on salient findings (e.g., mass presence and enhancement) and can detect cross-modal discrepancies between Fluid-Attenuated Inversion Recovery (FLAIR) signal characteristics and segmentation boundaries. On MIMIC-CXR, it generates structured reports and correctly recognises view-specific artefacts. Code: https://github.com/nican2018/rvlm.
Mar 25, 2026

NeuroVLM-Bench: Evaluation of Vision-Enabled Large Language Models for Clinical Reasoning in Neurological Disorders

Recent advances in multimodal large language models enable new possibilities for image-based decision support. However, their reliability and operational trade-offs in neuroimaging remain insufficiently understood. We present a comprehensive benchmarking study of vision-enabled large language models for 2D neuroimaging using curated MRI and CT datasets covering multiple sclerosis, stroke, brain tumors, other abnormalities, and normal controls. Models are required to generate multiple outputs simultaneously, including diagnosis, diagnosis subtype, imaging modality, specialized sequence, and anatomical plane. Performance is evaluated across four directions: discriminative classification with abstention, calibration, structured-output validity, and computational efficiency. A multi-phase framework ensures fair comparison while controlling for selection bias. Across twenty frontier multimodal models, the results show that technical imaging attributes such as modality and plane are nearly solved, whereas diagnostic reasoning, especially subtype prediction, remains challenging. Tumor classification emerges as the most reliable task, stroke is moderately solvable, while multiple sclerosis and rare abnormalities remain difficult. Few-shot prompting improves performance for several models but increases token usage, latency, and cost. Gemini-2.5-Pro and GPT-5-Chat achieve the strongest overall diagnostic performance, while Gemini-2.5-Flash offers the best efficiency-performance trade-off. Among open-weight architectures, MedGemma-1.5-4B demonstrates the most promising results, as under few-shot prompting, it approaches the zero-shot performance of several proprietary models, while maintaining perfect structured output. These findings provide practical insights into performance, reliability, and efficiency trade-offs, supporting standardized evaluation of multimodal LLMs in neuroimaging.