Subject-Held-Out Evaluation of Deep Ground Reaction Force Estimators Across Two Laboratories: Leakage and Cross-Laboratory Transfer

Authors: Hernan David Santos, Yinong Chen, Yu Ding, Xudong Zhang, Jian Tao

Organizations: Department of Electrical and Computer Engineering and the Texas A&M Institute of Data Science, Texas A&M University, College Station, TX 77843 USA · Department of Environmental and Occupational Health, Texas A&M University, College Station, TX 77843 USA · H. Milton Stewart School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA · Wm Michael Barnes ’64 Department of Industrial and Systems Engineering, Texas A&M University, College Station, TX 77843 USA · 

Abstract

Deep networks that estimate ground reaction forces and centers of pressure from motion-capture markers are validated within one laboratory, in a seldom-stated coordinate frame, and sometimes with trial-level splits that put the same person in the training and the test set. We measured what each practice costs, and whether such models transfer between laboratories. Three sequence models (convolutional, convolutional-recurrent, and convolutional-transformer) were evaluated on two independent datasets, locomotion (6 subjects) and occupational patient handling (10 subjects), under one pipeline, one tuning procedure, three seeds, and four protocols: trial-level split, leave-one-subject-out, pooled two-laboratory training with matched held-out subjects, and cross-laboratory transfer. At a fixed configuration, trial-level splits overstated the subject-held-out coefficient of determination by +0.040 to +0.194; on occupational data the overstatement exceeded every difference between architectures. With subjects held out, the three models reached values between 0.583 and 0.804; the leader differed between datasets, and gaps lay within subject-to-subject variability. Pooling the laboratories changed neither dataset on matched subjects. Transfer between laboratories was below chance in both directions, including the vertical force, which no in-plane rotation can affect. Leaving force targets in the plate frame while inputs were heading-aligned cost 0.57 of locomotion anteroposterior-force explained variance, enough to make that force look hardest; a Newton's-law correlation detected the mismatch before training. Split protocol and target frame changed reported accuracy more than architecture did. Learned force estimators should be validated with subjects held out, checked for frame consistency before training, and tested across laboratories before deployment claims are made.

Figures & tables

Explore similar work

May 24, 2026

Gait2Hip-60: A Unified Deep Learning Benchmark for Predicting Hip Muscle Forces and Joint Moments from Multi-Cadence Gait Kinematics

Estimating hip muscle forces and joint moments during gait typically relies on musculoskeletal simulation, which is informative but time-consuming and difficult to apply in clinical settings. This study developed a deep learning framework to predict these hip dynamics parameters directly from lower-limb gait kinematics and compared three representative sequence models under a unified protocol. Gait data were collected from 60 healthy adults under three metronome-guided cadence conditions. Ten bilateral lower-limb joint angles were used as inputs, and OpenSim-derived hip muscle forces and hip joint moments were used as reference outputs. Three deep learning models of LSTM, Transformer, and Mamba were trained and evaluated using the same subject-level split, preprocessing pipeline, and metrics. The best model was then directly tested on an external cohort of 9 patients with osteonecrosis of the femoral head (ONFH) without retraining. In the healthy-subject benchmark, Transformer achieved the best subject-level mean performance for both hip muscle force prediction (RMSE = 1.33 N/kg, MAE = 0.57 N/kg, R2 = 0.819) and hip joint moment prediction (RMSE = 0.11 Nm/kg, MAE = 0.07 Nm/kg, R2 = 0.862), with similar advantages across walking cadences. In zero-shot external validation, Transformer retained moderate predictive ability in ONFH for hip muscle force prediction (RMSE = 1.51 N/kg, MAE = 0.70 N/kg, R2 = 0.537) and hip joint moment prediction (RMSE = 0.17 Nm/kg, MAE = 0.12 Nm/kg, R2 = 0.569). These findings support the feasibility of estimating hip dynamics from gait kinematics, identify Transformer as a strong baseline, and highlight the need for broader pathological validation and improved generalization before clinical application.
Aug 3, 2026

Deep Learning-Based Estimation of Ground Reaction Forces in Parkinsonian Gait Using an Optimized Set of IMU Data

Accurate gait analysis in Parkinson's disease (PD) typically relies on laboratory-based systems to capture biomechanical data, such as ground reaction forces (GRFs). Estimating GRFs using inertial measurement units (IMUs) provides a feasible alternative. However, this approach remains challenging in pathological gait like PD due to its high variability and complexity. Moreover, existing monitoring approaches often require multiple body-mounted sensors, which limit practicality and reduce patient compliance. To date, no study has investigated the application of deep learning approaches to address this challenge. This study proposes, for the first time, a deep learning framework to estimate bilateral vertical GRFs (vGRFs) in PD using an optimized set of wearable IMUs. A hybrid CNN-BiLSTM model was trained separately on data from 61 PD patients and 65 healthy controls (HC) using 13 IMUs. The model achieved high intra-subject accuracy (R2R^2 = 0.98) and strong inter-subject generalization (R2R^2 = 0.93 for HC, R2R^2 = 0.91 for PD). Sensor configuration was found to significantly influence estimation accuracy, with optimal sensor placement varying between PD patients and HC. For PD patients, estimation accuracy dropped markedly when reducing to a single IMU. The optimal configuration for PD used four IMUs. We identified a minimal setup with only two IMUs still enabled robust estimation. This compact setup offers a practical and scalable solution. Overall, the proposed approach supports the development of wearable vGRF-based gait analysis systems for Parkinsonian gait and potentially other pathological conditions, enabling accessible clinical assessments, remote monitoring, and personalized rehabilitation.
Sep 28, 2026

Proprioceptive Force Estimation for Quadruped Locomotion and Human-Robot Interaction

Payload forces must be accommodated during locomotion, while leash forces can specify desired motion. We investigate whether a shared three-dimensional force estimate in newtons, inferred from proprioceptive history under sustained loading, can support both tasks. An estimator and locomotion policy are jointly trained with supervised force and velocity outputs and learned latent context. The estimated force conditions locomotion and additionally generates planar-velocity and yaw-rate commands for leash guidance through an analytical map. In sustained-force simulation sweeps, temporal means of componentwise force root mean square error range from 1.44 to 2.83,N. Compared with a domain-randomized baseline, the framework reduces velocity-tracking and base-orientation error scores by 21.6% and 46.5%, respectively, and increases mean survival from 68.29% to 94.60% in separate sustained-force tests. Unitree Go1 experiments demonstrate stationary vertical and horizontal force estimation, locomotion with an 8.5,kg payload whose weight exceeds the 70,N training force limit, and leash guidance using the same force-estimation interface.