Data Archive for 2D and 3D Electrical Impedance Tomography with moderate conductivity contrast phantoms
Authors: S. J. Hamilton, A. Hauptmann, A. Hänninen, V. Kolehmainen, J. Niskanen, T. Savolainen, J. Toivanen
Organizations: Department of Mathematical and Statistical Sciences; Marquette University, Milwaukee, WI 53233 USA · Research Unit of Mathematical Sciences; University of Oulu, Oulu, Finland · Department of Computer Science; University College London, London, United Kingdom · Department of Applied Physics; University of Eastern Finland, Kuopio, Finland · Department of Technical Physics; University of Eastern Finland, Kuopio, Finland
This document describes open Electrical Impedance Tomography (EIT) measurement data that were collected from biomedical imaging inspired phantoms with moderate conductivity contrasts. The data were collected with the KIT4 and KIT5 EIT measurement devices at the University of Eastern Finland, and are intended for EIT image reconstruction algorithm development and testing. The data from thoracic imaging inspired cylindrical and chest-shaped phantoms are suitable for 2D algorithms, and the data from an intracerebral hemorrhage imaging inspired head-shaped phantom with resistive skull are suitable for 3D algorithms. In addition to the measurement data, computational meshes and example reconstruction codes are provided and sample reconstructions included.
Figures & tables
Figure 1. Agar phantom measurement setups for the cylinder phantom (top row) and the chest phantom (bottom row).
Figure 2. Head phantom measurement setups separated based on the location of the conductive cylinder.
Figure 3. The KIT4 measurement device is shown on the left, and the KIT5 on the right.
Figure 4. Sample linear difference imaging reconstructions (left) and smoothness regularized absolute reconstructions (right) using the AgarChestPhantom data.
Figure 5. Sample linear difference imaging reconstructions using a growth case from the HeadPhantom data. A 3D visualization is displayed as well as a 2D slice of that reconstruction.
Figure 6. Computational meshes with (top row) and without (middle row) electrodes for the three different phantoms (columns) as well as their dimensions (bottom row).
This study proposes a bound-constrained sparse representation (BC-SR) framework for electrical impedance tomography (EIT), aimed at improving conductivity estimation without explicit regularization. BC-SR adopts a representation-driven strategy, generating conductivity from low-dimensional latent variables via an implicit composite parameterization. Structural priors are embedded using a truncated graph-Laplacian basis, while a bound-preserving nonlinear mapping enforces admissible conductivity ranges and improves conditioning through implicit gradient modulation. The approach ensures robust convergence, even under noisy or incomplete data. Extensive validation on 2D/3D simulations, tank experiments, and in-vivo lung data shows that BC-SR improves physical consistency and structural fidelity, offering enhanced robustness compared to traditional methods. Additionally, BC-SR enables 3D time-difference EIT reconstruction, offering improved spatial resolution and a more coherent representation of 3D conductivity distributions, particularly for in-vivo lung data. This suggests potential for improved performance in EIT, particularly in clinical applications for respiratory monitoring.
Chun Zhang, Dong Liu
School of Biomedical Engineering and Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou 215123, China · Laboratory of Spin Magnetic Resonance and Anhui Province Key Laboratory of Scientific Instrument Development and Application, University of Science and Technology of China, Hefei 230026, China · Jiangsu Provincial Key Laboratory of Multimodal Digital Twin Technology, Suzhou 215123, China
Multi-Frequency Electrical Impedance Tomography (MF-EIT) is a non-invasive, low-cost modality that reconstructs electrical property distributions from boundary voltages. For stroke imaging, progress in 3D deep-learning reconstruction is limited by the lack of large-scale datasets with paired ground-truth (GT) volumes and by non-standardized pipelines for data generation, simulation, and evaluation. We introduce BREIT, a modular framework for 3D MF-EIT stroke reconstruction providing: (i) a neuroimaging-to-EIT pipeline that converts CT/MRI into frequency-dependent GT admittivity volumes; (ii) a self-contained Python 3D Complete Electrode Model (CEM) forward solver for simulating MF-EIT voltages; and (iii) a 3D D-bar implementation supporting non-uniform electrode layouts. Building on BREIT, we propose dFNO-bar, which integrates Fourier Neural Operators into D-bar by learning a mapping from scattering data t(ξ) to conductivity σ(x)=ℜ{γ}. We evaluate dFNO-bar against D-bar, Deep D-bar, and Gauss--Newton reconstructions on UCLH-matched synthetic data, and observe higher brain SSIM with comparable CC across noise settings.
Djahid Abdelmoumene, Ishak Ayad, Maï K. Nguyen +1
ETIS (UMR 8051), CY Cergy Paris University, ENSEA, CNRS, Cergy France · AGM (UMR 8088), CY Cergy Paris University, CNRS, Cergy, France · Paris-Saclay University, CentraleSupélec, Inria, CVN, Gif-sur-Yvette, France
Deep generative models have emerged as state-of-the-art for solving inverse problems, but applying them to inverse problems for PDEs, like electrical impedance tomography (EIT) remains challenging. Because physical domains are naturally discretized as unstructured meshes rather than regular grids, standard convolutional architectures are often inadequate. In this paper, we propose a novel framework that extends diffusion posterior sampling (DPS) to graph-structured data. We develop an unconditional score-based diffusion model directly on a 2D triangular mesh to learn an accurate prior over the physical solution space. Furthermore, we introduce a regularized variant, RDPS, which incorporates explicit regularization terms, such as total variation and generalized Tikhonov, to complement the implicit diffusion prior and mitigate severe ill-posedness. Extensive experiments on synthetic and real 2D EIT datasets demonstrate that RDPS produces stable, physically plausible reconstructions. Our approach generalizes well to out-of-distribution inclusion geometries, is highly robust to measurement noise, and outperforms current state-of-the-art solvers (e.g., GPnP-BM3D, DP-SGS) in reconstruction accuracy and artifact reduction.
Giovanni S. Alberti, Damiana Lazzaro, Serena Morigi +2
MaLGa Center, Department of Mathematics, University of Genova, Italy · Department of Mathematics, University of Bologna, Bologna, Italy · Department of Mathematics, Harbin Institute of Technology, China