cs.CVNov 13, 2026

PADSNet: Physics-Aware Dual-Stream Network with Biomechanical Priors for Laryngeal Lesion Classification

Authors: Zhenzhen You, Weifeng Yu, Zhenghao Shi, Shuangli Du, Minghua Zhao, Yingcheng Zhao, Xinhong Hei, Demin Kong, 

Organizations: Human-Machine Integration Intelligent Robot Shaanxi University Engineering Research Center, School of Computer Science and Engineering, Xi'an University of Technology, Xi'an, China · Department of Otolaryngology, Second Affiliated Hospital of Medical College, Xi'an Jiaotong University, Xi'an, China

Abstract

Precise classification of laryngeal lesions is clinically crucial yet highly challenging, as inter-class visual differences are often subtle. While abnormalities in vocal fold vibratory dynamics provide complementary discriminative information, existing deep learning models predominantly rely on visual appearance and lack explicit mechanisms for modeling clinically meaningful vibratory dynamics. To address this, we propose PADSNet, a Physics-Aware Dual-Stream Network for laryngeal lesion classification that integrates visual representations with explicit biomechanical reasoning. Specifically, a Wavelet-Attention Enhancement Module (WAEM) is designed to bridge the spectral-semantic gap, enabling complementary learning of spatial texture and dynamic frequency representations. Meanwhile, a Knowledge Computing Module (KCM) extracts interpretable biomechanical indices from temporal glottal distance waveforms, including indicators of mobility, symmetry, glottal closure, and vibration stability. These descriptors are subsequently incorporated into a Physics-Aware Gating Module (PAGM) as biomechanical priors to adaptively recalibrate visual feature toward pathology-relevant vibratory patterns. Extensive experiments on a clinical dataset demonstrate that PADSNet achieves an accuracy of 0.8452, an F1-score of 0.8090, a sensitivity of 0.7953, and a specificity of 0.8866. These results indicate that explicitly integrating biomechanical priors with deep visual representations provides a more accurate, robust, and clinically interpretable framework for automated laryngeal lesion classification.

Explore similar work

Sep 22, 2026

Laryngeal Structure Segmentation in High-Speed Videoendoscopy Using Deep Learning

Laryngeal high-speed videoendoscopy (HSV) offers an effective means of observing the motion of different laryngeal structures along with vibratory behaviors of the vocal folds under various voicing conditions. Segmentation of laryngeal tissues enables analysis of different tissue structures and their dynamics, helping characterize the involvement of laryngeal muscles in voice production. Given the large number of HSV frames, automating this task is imperative. While deep learning-based methods have been implemented in previous studies to segment laryngeal structures, they have not been applied to HSV data during connected speech, which poses significant challenges due to excessive tissue movements and image quality limitations associated with fiberoptic image acquisition. The application of deep learning to connected speech data is critical for capturing nonstationary laryngeal behaviors and identifying anomalous patterns associated with voice disorders. The present study aims to address these gaps by training U-Net models to detect the aryepiglottic folds and arytenoid cartilages, vocal folds, epiglottis, and glottal area, using HSV data from both sustained vowel phonation and connected speech obtained from normophonic and disordered voices. Image pre-processing techniques, including noise removal and histogram equalization, were applied to improve the quality of the training HSV images and enhance network performance. Finally, to evaluate the accuracy and reliability of the networks, quantitative performance metrics were used alongside qualitative visual inspection of the test images. The high performance of the developed networks, with overall accuracies exceeding 95%, establishes their potential as reliable tools for automated laryngeal image analysis, quantitative characterization of laryngeal dynamics, and future detection of anomalous laryngeal behaviors in clinical settings.
Jul 20, 2026

Medical Imaging Fusing Vision Transformer: Laryngeal Cancer Screening with Explanation

Early and timely screening of laryngeal cancer is crucial for improving clinical outcomes. In recent years, NBI endoscopy has become a standard diagnostic tool for the detection of laryngeal lesions. However, its effective use requires well-trained clinicians and the procedure is time-consuming and subject to interobserver variability. In this context, the application of artificial intelligence (AI) offers a promising solution to support clinical decision-making. In this work, we proposed applying transformer and attention mechanism for analyzing the narrow band imaging and distinguish benign and malignant lesions. Results show it has good classification performance with F1 (82.72%), accuracy(82.33%). In addition, the result of laryngeal cancer screening is explainable for clinicians. The explainability is utilizing the state of art segmentation method (MedSAM) to provide the useful pathological information area for clinicians. The proposed methodology fusing classification and segmentation provides a translating on laryngeal cancer screening.
Oct 13, 2025

Benchmarking Deep Learning Models for Laryngeal Cancer Staging Using the LaryngealCT Dataset

Laryngeal cancer imaging research lacks standardised public datasets to enable reproducible deep learning (DL) model development. We present LaryngealCT, a curated benchmark of 1,029 computed tomography (CT) scans aggregated from six collections from The Cancer Imaging Archive (TCIA). Uniform 1 mm isotropic volumes of interest encompassing the larynx were extracted using a weakly supervised parameter search framework validated by clinical experts. Six 3D DL architectures (custom 3D CNN, ResNet18,50,101, DenseNet121 and MedicalNet-pretrained ResNet50) were benchmarked on (i) early (Tis,T1,T2) vs. advanced (T3,T4) and (ii) T4 vs. non-T4 classification tasks. On the independent test set, the 3D CNN achieved the strongest overall performance across global and per-class metrics (Accuracy 0.854, F1-macro 0.841) in early vs. advanced classification. In the T4 task, AU-ROC values exceeded 0.82 for most models, but sensitivity for T4 disease remained limited (less than or equal to 0.412), with ResNet101 showing the most promising calibrated T4 recall (0.706. Model explainability assessed using GradCAMpp with thyroid cartilage overlays for T4 classification task revealed anatomically plausible peri-cartilage activations, although spatial overlap was modest. Through open-source data, pretrained models, and integrated explainability tools, LaryngealCT offers a reproducible foundation for AI-driven research to support future clinical decision-making in laryngeal oncology.