cs.AINov 13, 2026

Understanding the limits of snapshot-based fault diagnosis in distribution networks

Authors: Ba Tu Phung, Huy Hoang Le, Kim-Anh Nguyen

Organizations: Faculty of Electrical Engineering, University of Science and Technology, The University of Danang, 54 Nguyen Luong Bang Street, Da Nang 550000, Vietnam · R&D Department, PowerMore Ltd., Da Nang 550000, Vietnam

Abstract

Inverter-based resources weaken fault currents in distribution networks, and snapshot-based diagnosis, which classifies a fault from voltage phasors at a few buses at one instant, offers a cheap first-stage screen. Its published accuracies, however, rest on different noise assumptions and do not show whether the error comes from the classifier, the features, the measurement error, or the fault resistance. This paper separates these sources on three IEEE test feeders and a public data set with distributed generation, using four feature sets, thirteen classifiers, and measurement error defined by total vector error classes. The classifier is not the limiting factor, because the full phasor snapshot classifies every fault correctly without noise, and the remaining error comes from measurement error on high-impedance faults. Three voltage sensors classify 90-96% of faults at the 1% accuracy class and 96-99% with distribution micro phasor measurement units (micro-PMUs). A discriminability-margin placement selects them from simulations alone in under one second and matches the best of twelve placement methods. The results show when snapshot-based diagnosis can be trusted.

Figures & tables

Explore similar work

Feb 27, 2026

FaultXformer: A Transformer-Encoder Based Fault Classification and Location Identification model in PMU-Integrated Active Electrical Distribution System

Accurate fault detection and localization in electrical distribution systems is crucial, especially with the increasing integration of distributed energy resources (DERs), which inject greater variability and complexity into grid operations. In this study, FaultXformer is proposed, a Transformer encoder-based architecture developed for automatic fault analysis using real-time current data obtained from phasor measurement unit (PMU). The approach utilizes time-series current data to initially extract rich temporal information in stage 1, which is crucial for identifying the fault type and precisely determining its location across multiple nodes. In Stage 2, these extracted features are processed to differentiate among distinct fault types and identify the respective fault location within the distribution system. Thus, this dual-stage transformer encoder pipeline enables high-fidelity representation learning, considerably boosting the performance of the work. The model was validated on a dataset generated from the IEEE 13-node test feeder, simulated with 20 separate fault locations and several DER integration scenarios, utilizing current measurements from four strategically located PMUs. To demonstrate robust performance evaluation, stratified 10-fold cross-validation is performed. FaultXformer achieved average accuracies of 98.76% in fault type classification and 98.92% in fault location identification across cross-validation, consistently surpassing conventional deep learning baselines convolutional neural network (CNN), recurrent neural network (RNN). long short-term memory (LSTM) by 1.70%, 34.95%, and 2.04% in classification accuracy and by 10.82%, 40.89%, and 6.27% in location accuracy, respectively. These results demonstrate the efficacy of the proposed model with significant DER penetration.
Oct 31, 2026

Benchmarking Classical Machine Learning Models for Shading-Fault Detection in Rooftop Photovoltaic Systems Using Real Sensor Data

Most published comparisons of machine-learning classifiers for photovoltaic (PV) fault detection are validated on simulated faults. We compare seven classical and ensemble-tree classifiers on the Réunion dataset, a 4 kW domestic rooftop plant on which shading faults were physically staged and logged. Readings within a staged episode are near-duplicates, so every train/test split is grouped by episode. A 20,800-row subsample that retains all 17 fault episodes was evaluated with three repeats of five-fold group-aware nested cross-validation, with synthetic minority oversampling (SMOTE) applied inside the training folds. Random Forest and XGBoost gave the highest mean accuracy (0.838 and 0.831) and Matthews correlation coefficient (MCC; 0.526 and 0.522). After Holm correction across the 21 pairwise Wilcoxon tests, only Random Forest's accuracy advantage over k-nearest neighbours and the multi-layer perceptron remained significant. Logistic Regression and the Decision Tree (accuracy 0.820) could be separated neither from the ensembles nor from the weakest models. SMOTE lowered binary MCC for six of the seven classifiers. Errors were concentrated in whole episodes: the Random Forest almost entirely missed four of the 17 fault episodes, including one of two uniform-shading and two of five intermittent-shading episodes. A post-hoc diagnostic shows that the no-fault rows were sampled over a wider range of times of day and output levels than the fault rows. Clock time alone reaches an MCC of 0.44, and PV-side voltage alone 0.72. The reported scores therefore reflect operating-condition differences as well as shading signatures. We release the pipeline and the diagnostics, and identify matched no-fault sampling as the step needed before the classifier ranking can be generalised.
Jul 31, 2026

Assessing the Generalization of Graph Neural Networks for Fault Location Across Increasing Distributed Energy Resource Penetration Levels

Accurate fault location is critical for distribution network reliability. However, increasing distributed energy resource (DER) penetration complicates fault location due to intermittent generation and bidirectional power flows that reshape fault signatures. Spatio-Temporal Graph Neural Networks (STGNNs) have shown promise by jointly modeling spatial and temporal dependencies, but their behavior under increasing DER penetration has not been studied rigorously. In this paper, we (i) systematically benchmark spatio-temporal graph attention network (STGATv2) against purely temporal (gated recurrent unit, GRU), purely spatial (GATv2) and traditional machine learning baselines, and (ii) evaluate how well models generalize across increasing DER penetration levels (10%, 25%, 50%) on a reconfigured IEEE 123-bus feeder with multiple DER injection points and moderate-to-high impedance faults. Results show that STGATv2 consistently outperforms neural baselines, achieving 92-94% macro F1 in-distribution. Notably, generalization across penetration levels is asymmetric: training at 50% penetration retains near in-distribution F1 score at lower levels, whereas training at 10% degrades considerably at 50% - with STGATv2 retaining 81-84% F1 under these drastic shifts, substantially higher than GATv2 and GRU which drop to 69-74% F1 and 73-75% F1 respectively. Under realistic measurement noise, STGATv2 maintains > 85% F1, while GRU drops as low as 33.5% F1, highlighting the critical role of topological awareness for robust fault location in active distribution networks.