Fix, Don't Retake: Physics-Simulated Training for Correcting Patient Positioning Errors in Dental Panoramic Radiographs
Organizations: Department of Computer Science and Software Engineering, College of Computing and Artificial Intelligence, United Arab Emirates University, UAE · Faculty of Dental Medicine and Oral Health Sciences, McGill University, Canada · Department of Oral and Craniofacial Health Sciences, College of Dental Medicine, University of Sharjah, UAE
Abstract
Patient-positioning errors can distort panoramic radiographs and lead to repeat examinations. This study investigated artificial intelligence for correcting these errors in existing images. A physics-based simulator generated paired correctly positioned and mispositioned panoramics from cone-beam computed tomography volumes, with controlled individual and combined positioning errors. Five approaches were compared: U-Net, pix2pix, conditional diffusion, an error-conditioned model, and a mixture of error-specific specialists. Evaluation used image similarity and geometric metrics across three test sets. All approaches improved mean image similarity and reduced geometric errors, with U-Net and the two error-aware approaches outperforming pix2pix and conditional diffusion.
Figures & tables
| Error | Mild | Moderate | Severe |
|---|---|---|---|
| Forward/backward (mm) | 2–4 | 4–7 | 7–10 |
| Chin down/up ( ∘ ) | 3–6 | 6–10 | 10–15 |
| Head turn ( ∘ ) | 4.5–6 | 6–9 | 9–12 |
| Head tilt ( ∘ ) | 2–4 | 4–6 | 6–9 |
| Tongue air gap (mm) | 1.5–3 | 3–6 | 6–10 |
| Natural | Balanced | Unseen geometry M4 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Approach | PSNR | SSIM | IWE | LRE | PSNR | SSIM | IWE | LRE | PSNR | SSIM | IWE | LRE |
| Uncorrected | 18.81 | .577 | 5.57 | 5.99 | 16.64 | .458 | 5.91 | 6.62 | 17.90 | .550 | 5.32 | 6.73 |
| U-Net | 23.25 | .703 | 2.64 | 2.04 | 21.59 | .659 | 1.78 | 1.93 | 21.25 | .649 | 3.10 | 2.93 |
| pix2pix | 21.51 | .634 | 3.79 | 3.17 | 19.72 | .566 | 2.43 | 3.00 | 19.85 | .586 | 4.01 | 4.33 |
| Cond. diffusion | 21.18 | .624 | 3.62 | 3.30 | 19.32 | .565 | 2.68 | 2.76 | 19.31 | .562 | 3.96 | 3.62 |
| Error-conditioned | 23.62 | .705 | 2.76 | 1.95 | 21.97 | .667 | 2.33 | 1.80 | 21.54 | .656 | 3.11 | 2.65 |
| Level | Approach | PSNR | SSIM | IWE | LRE |
|---|---|---|---|---|---|
| Mild | Uncorrected | 18.55 | .516 | 2.45 | 3.35 |
| U-Net | 22.51 | .692 | 2.08 | 1.61 | |
| pix2pix | 20.77 | .616 | 2.01 | 2.28 | |
| Cond. diffusion | 20.35 | .607 | 2.54 | 1.68 | |
| Error-conditioned | 23.04 | .698 | 2.53 | 1.35 | |
| Mixture of specialists | 23.15 | .712 | 2.21 | 1.44 |
Medical Imaging
Medical imaging uses computational methods to analyze, reconstruct, and interpret images for diagnosis, treatment planning, and monitoring.
See all 270 papers