All-electric heavy-duty robotic manipulators are increasingly expected to operate close to tunnel walls, equipment, and other structures while retaining the force capability required for large-payload tasks. Accurate motion control alone does not address the resulting safety and interaction requirements. This paper develops a safety-aware physical-interaction architecture that combines variable impedance control (VIC) with control barrier functions (CBFs) on top of an established virtual decomposition control (VDC) framework for electromechanical linear actuator (EMLA)-driven manipulators. VIC continuously adapts the task-space stiffness and damping according to predicted proximity and contact risk, whereas a joint-velocity CBF filter enforces Cartesian workspace boundaries and the physical stroke limits induced by the closed-chain lift and tilt mechanisms. To account for nonideal realization of the filtered velocity by the inner VDC/EMLA dynamics, the CBF inequalities are tightened using a measured bound on the joint-velocity tracking error. Four configurations, namely VDC, VIC+VDC, CBF+VDC, and VIC+CBF+VDC, are evaluated under workspace, actuator-limit, and physical-interaction scenarios. VIC reduces the peak and RMS environment-interaction forces by 92.59% and 96.33%, respectively; both robust CBF configurations maintain positive workspace and EMLA safety margins, while VIC+CBF+VDC reduces the CBF intervention metric by 10.30% compared with CBF+VDC.
Figures & tables
Figure 1: Proposed VIC–CBF–VDC control architecture for safe physical interaction of the all-electric HDRM.
Figure 2: All-electric HDRM and safety scenario with hard wall/ceiling constraints.
Figure 3: Commanded HDRM motion in the xy -plane together with the physical workspace boundaries.
Parameter
Value
Physical wall / ceiling
3.60/3.10 m
Environmental margin denv
0.05 m
Safe wall / ceiling
3.55/3.05 m
VIC warning distance dwarn
0.40 m
Physical EMLA stroke range
[0.05,0.45] m
Stroke safety margin dstroke
0.01 m
Table 1: Main VIC, Safety, and Contact Parameters
Method
Description
VIC
CBF
0
Original VDC
–
–
1
VIC + VDC
✓
–
2
CBF + VDC
–
✓
3
VIC + CBF + VDC
✓
✓
Table 2: Compared Control Configurations
Method
eRMSE
minhenv
minhEMLA
max∥ev∥2
JCBF
Peak/RMS ∥Fenv∥2
Safe?
[m]
[m]
[m]
[rad/s]
[rad 2 /s]
[N]
VDC
0.0417
-0.0510
-0.0327
–
–
20773.5/12204.3
No
VIC+VDC
0.0202
-0.0330
-0.0325
–
–
1539.4/448.4
No
CBF+VDC
0.0043
0.0121
0.0014
0.0154
89.37
0.0/0.0
Yes
VIC+CBF+VDC
0.0070
0.0121
0.0014
0.0154
80.16
0.0/0.0
Yes
Table 3: Quantitative comparison of the four control configurations.
Figure 4: Validation of the proposed VIC–CBF–VDC architecture (Method 3). From top to bottom: end-effector motion in the x -direction, end-effector motion in the y -direction, lift and tilt EMLA strokes, and the six workspace and EMLA CBFs.