BiMa-ECGSR: reconstructing the 12-lead ECG from reduced lead sets with bidirectional state-space models

Authors: Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi

Organizations: Department of Surgical and Medical Sciences, Magna Graecia University of Catanzaro, Catanzaro, Italy · Department of Informatics Modelling and Systems, University of Calabria, Rende, Italy

Abstract

Wearables and monitors record few electrocardiogram (ECG) leads; most diagnostic tools assume 12 leads. BiMa-ECGSR reconstructs the 12-lead ECG from reduced lead sets with a bidirectional Mamba state-space encoder--decoder, as regression (BiMa-SR) or diffusion (DiBiMa-SR). Models were trained on PTB-XL for six input sets (I; II; I+II; I+II+V1; I+II+V2; I+II+V1+V4), see only the measured leads at inference, and were tested on the PTB-XL test fold (2,198 records) and two external cohorts (Georgia, 10,275 records; Chapman-Shaoxing/Ningbo, 43,559). From lead II alone, the pooled median Pearson correlation (PCC) over the 11 predicted leads was 0.914 on PTB-XL, against 0.784 for a least-squares linear filter (lead I: 0.906 against 0.789). As limb leads are exactly derivable from I and II, multi-lead inputs were compared on predicted chest leads: 0.939 against 0.849 for I+II and 0.979 against 0.962 for I+II+V1+V4. BiMa-SR exceeded the linear comparator in all 18 configuration--cohort pairs (by 0.012--0.136), a margin that shrank as chest leads were added. From lead II, regression was more accurate than diffusion (DiBiMa-SR: 0.903 one-step, 0.862 with six DDIM steps). A 12-lead classifier trained only on real ECGs reached a superclass macro AUROC of 0.912 on real PTB-XL ECGs, 0.843 on reconstructions from lead II and 0.908 from I+II+V1+V4; externally, reconstructions from three or four leads scored within 0.004 of real ECGs. BiMa-SR (2.68,M parameters) takes 45.8 ms per 10-s record on a GPU. Reconstruction makes reduced-lead recordings usable by 12-lead tools; it cannot add information absent from the measured leads.

Figures & tables

Explore similar work

Mar 18, 2026

Pathology-Aware Multi-View Contrastive Learning for Patient-Independent ECG Reconstruction

Reconstructing a 12-lead electrocardiogram (ECG) from a reduced lead set is an ill-posed inverse problem due to anatomical variability. Standard deep learning methods often ignore underlying cardiac pathology losing vital morphology in precordial leads. We propose Pathology-Aware Multi-View Contrastive Learning, a framework that regularizes the latent space through a pathological manifold. Our architecture integrates high-fidelity time-domain waveforms with pathology-aware embeddings learned via supervised contrastive alignment. By maximizing mutual information between latent representations and clinical labels, the framework learns to filter anatomical "nuisance" variables. On the PTB-XL dataset, our method achieves approx. 76% reduction in RMSE compared to state-of-the-art model in patient-independent setting. Cross-dataset evaluation on the PTB Diagnostic Database confirms superior generalization, bridging the gap between hardware portability and diagnostic-grade reconstruction.
Jul 6, 2026

ImputeECG: Deep Learning Reconstruction of Complete 12-Lead Electrocardiograms from Incomplete Recordings for Cardiac Assessment

Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption. We developed ImputeECG, a mask-conditioned one-dimensional Transformer autoencoder that completes 12-lead, 10-s ECGs while retaining all observed samples. The model was trained on PTB-XL and evaluated on PTB-XL and CPSC2018 under simulated incomplete settings, with additional real-world validation in a 43,633-record Kailuan clinical cohort after ECG image digitization. Metrics were computed over originally missing regions, with analyses of morphology and downstream diagnostic utility. On PTB-XL, ImputeECG reduced missing-region MAE by 41.7-51.0% and MSE by 54.0-63.7% versus the strongest baseline, with lower errors in R-peak timing, RR interval, QRS duration, QT interval, and P-wave, QRS-complex, and T-wave reconstruction. On CPSC2018, ImputeECG reduced MAE by 49.7-51.9%, supporting external generalization. In downstream multi-label classification, ImputeECG restored performance to 92.28% AUROC and 33.88% AUPRC in the most incomplete PTB-XL setting, approaching complete-ECG performance. On CPSC2018, completed ECGs achieved 94.75-95.89% AUROC and 78.83-81.86% AUPRC across settings. In Kailuan, ECG completion improved zero-shot sex prediction AUROC from 82.6% to 85.8% and reduced age prediction MAE from 10.72 to 9.87 years after image-based ECG digitization. These findings support ECG completion as a practical strategy for converting incomplete ECG records into AI-ready 12-lead, 10-s digital signals and extending the usable scope of ECG archives for digital cardiac assessment.
Mar 16, 2026

Vib2ECG: A Co-Located Chest-Lead SCG-ECG Dataset and Benchmark for ECG Reconstruction

Twelve-lead electrocardiography (ECG) is essential for cardiovascular diagnosis, but its long-term acquisition in daily life is constrained by complex and costly hardware. Recent efforts have explored reconstructing ECG from low-cost cardiac vibrational signals such as seismocardiography (SCG), with prior studies primarily focusing on limb leads, while clinical diagnosis requires multi-lead ECG, including chest leads. In this work, we propose Vib2ECG, a dataset of synchronized, co-located ECG and chest-wall vibration recordings, which includes complete twelve-lead ECGs and vibrational signals acquired by inertial measurement units (IMUs) at the six standard precordial electrode sites (V1-V6) from 17 subjects. Based on this dataset, we also provide a benchmark. Experimental results demonstrate the feasibility of reconstructing electrical cardiac signals at variable locations from vibrational signals using a lightweight 364K-parameter U-Net. Furthermore, we observe a hallucination phenomenon in the model, where ECG waveforms are generated in regions where no corresponding electrical activity is present. We analyze the causes of this phenomenon and propose potential directions for mitigation. This study demonstrates the feasibility of mobile-device-friendly ECG monitoring through chest-lead ECG prediction from low-cost vibrational signals acquired using IMU sensors. It expands the application of cardiac vibrational signals and provides new insights into the spatial relationship between cardiac electrical and mechanical activities with spatial location variation.