cs.CVNov 17, 2026

MedHarness: A Unified Budgeted Runtime for Reliable Medical Imaging Agents

Authors: Haofan Wu, Le Zhang

Organizations: University of Birmingham

Abstract

Medical imaging agents already return answers on heterogeneous imaging surfaces, yet deployment still faces a limited verification budget where each wrong accept can harm clinical trust. When a thin check and a deeper evidence pass disagree on the same case, deciding when to stop, open more evidence, repair, or reject without a shared controller remains ill-posed. Tool-using workflows often lock a surface-specific evidence order per dataset, or a private always-open full-depth verification path; those pipelines stay costly, leave many wrong accepts, and cannot share one controller across modalities. We present MedHarness, a registered multi-surface runtime reliability layer that reformulates post-answer control as shared decision-object attachment after a proposer's initial prediction. Under Shared Decision Object, Minimum-Sufficient Verification, and Intermediate Repair, one shared policy with surface recipe adapters lets a new imaging surface join the same stop / open-evidence / repair / reject controller by recipe registration. On a 512-case live pool, MedHarness cuts wrong accepts versus a full-verification baseline by about 47% and raises accepted accuracy to 83.2% vs. 72.9% at 86.1% coverage versus full release under that baseline. On a failure-enriched multi-surface stress ranking, the same controller cuts estimated remote service calls per case by about 71% versus that baseline under a matched context-load setting. A held-out three-surface check and an alternate language-model transfer keep the same control ordering. The code is available at https://anonymous.4open.science/r/MedHarness-paper-release-A7F3/.

Figures & tables

Explore similar work

Oct 11, 2026

MedHarnessBench: A Unified Benchmark for Healthcare Agent Evaluation

Healthcare agents must transform longitudinal clinical evidence into reliable actions through heterogeneous tools and stateful workflows, conditions under which model-centric systems may lose context, misuse tools, fail to verify consequential transitions, or cross authorization boundaries. Existing medical-agent benchmarks primarily emphasize terminal task outcomes, making it difficult to determine whether execution failures arise from the agent model, the runtime harness, or their interaction. We present the Medical Harness Protocol, an outcome-preserving framework that independently evaluates seven healthcare-specific process dimensions: Care Action Fulfillment, Clinical Resource Competence, Patient-Evidence Alignment, Clinical Workflow Continuity, Clinical Auditability, Closed-Loop Verification, and Clinical Conduct Boundaries. A normalized intervention trace further tracks whether runtime support is available, activated, delivered, adopted by the agent, and propagated into subsequent behavior. We instantiate the protocol as MedHarnessBench, comprising 342 executable tasks across FHIR/EHR operations, healthcare-administration interfaces, and multimodal clinical tools. Across more than 16,000 controlled task executions, MedHarness yields broad improvements in terminal task success, intermediate subtask completion, and healthcare-specific process quality. We further evaluate MedHarness against multiple general-purpose harnesses and use controlled single-fault perturbations to verify the sensitivity and discrimination of the seven-dimensional evaluation. These results demonstrate that healthcare-specific runtime support can substantially improve both task completion and execution quality, while revealing failures that terminal outcomes alone cannot capture. Code and resources are available at https://github.com/Tomry1114/Awesome-Agent-Harness-for-Healthcare.
Mar 25, 2026

MedOpenClaw and MedFlowBench: Auditing Medical Agents in Full-Study Workflows

Medical imaging benchmarks often evaluate VLMs on pre-selected 2D images, slices, crops, or patches, making evaluation closer to visual recognition. Real clinical workflows impose a different burden: readers must search through complete studies, operate imaging software, navigate across slices and magnifications, and document visual evidence that can be audited. We argue that this evidence-producing workflow is a critical missing evaluation axis for medical imaging agents. To study it, we introduce MedFlowBench, a full-study benchmark for VLM agents, together with MedOpenClaw, a controlled and replayable runtime in which agents operate medical imaging viewers such as 3D Slicer and QuPath. In each episode, an agent inspects a complete radiology study or whole-slide pathology image, returns a task answer, and submits structured evidence, including key slices, coordinates, regions of interest, or lesion-state fields. This evidence is automatically checked against withheld masks, annotations, and labels. Across evaluated models, final answer-only scoring gives an overly optimistic picture: when answers must also be supported by correct evidence, performance drops substantially on complex workflows. We further find that adding image-analysis tools does not by itself solve the problem. Tools help when they make a complex procedure simple and reliable, but agents still struggle when they must choose inputs, manage viewer state, and verify intermediate outputs over multiple steps. MedFlowBench exposes whether medical imaging agents can produce auditable evidence from complete studies, rather than plausible answers from selected images.
Oct 3, 2026

MedImageOSWorld: Benchmarking GUI Agents for Medical Image Consoles

Graphical consoles offer a practical interface for medical acquisition assistance, allowing agents to work through the controls and visual feedback used by human operators. Reliable assistance requires linking on-screen anatomy to acquisition decisions that determine what image evidence becomes available next. We introduce MedImageOSWorld, a benchmark for evaluating this capability in simulated CT, MR, and ultrasound consoles. Using screenshots and mouse-and-keyboard actions, agents configure protocols, plan acquisitions, inspect the resulting images, and make corrective adjustments across seven capability levels, from console operation to feedback-driven control. Evaluation combines task-specific workflow checks with hidden anatomical ground truth to assess procedural completion and acquisition outcomes separately. A common evaluation protocol specifies episode conditions and interaction budgets, while recorded trajectories support analysis of how agents observe, act, and respond to acquisition feedback. Across eleven open-weight agents, success rates range from 3.0 to 25.0 on a 0-100 scale while workflow-progress rates reach 21.5-74.5: agents complete much of the console workflow but rarely acquire the intended anatomy. Success collapses between perception and planning, from 79-90% at the lowest three levels for the best agent to at most 12% for millimetre-level planning and 0% for closed-loop control among open-weight agents. Two proprietary agents reach success rates of about 34 and exceed the best open-weight agent mainly in acquisition quality (61 versus 42). MedImageOSWorld provides a controlled setting for studying whether general-purpose GUI agents can translate visual observations into effective medical acquisition decisions.