cs.AINov 18, 2026

GALA: Gallery-Level Alignment for Real-Life Vision Decoding from EEG

Authors: Philippe Forest, Giulia Lioi, Mai Pham Quyen, Alix Lamouroux, Javen Shi, Adrien Merlini

Organizations: IMT Atlantique, France · Center for Mind/Brain Sciences (CIMeC), University of Trento, Italy · Australian Institute for Machine Learning, University of Adelaide, Australia

Abstract

Neural decoding of visual experience from electroencephalography (EEG) has achieved strong performance in intra-subject settings, but current methods fail to generalize across individuals: on the standard 200-way benchmark THINGS-EEG-2, top-1 accuracy drops from above 80% within subjects to about 32% for an unseen subject. Adapting a pre-trained encoder to new subjects and sessions typically requires labeled data, a bottleneck whose collection time severely limits practical device deployment. In a practical Brain-Computer Interface (BCI), however, the possible outcomes are known in advance and form a gallery of candidates, and the unlabeled EEG of the user accumulates as soon as the device is used. We propose a new setting, incremental transductive calibration, in which the decoder is calibrated regularly on all the unlabeled EEG received so far and on the known gallery, without any labels. This setting is closer to the conditions of a deployed BCI than the zero-shot and batch evaluations in current use. We evaluate it with a protocol in which queries arrive one at a time, with unknown and possibly unequal frequencies, and each query is decoded before it is used for calibration. In this setting, we introduce GALA : GAllery-Level Alignment, a label-free calibration method which registers the unlabeled EEG embeddings onto the gallery through shrinkage whitening, hubness correction and a Sinkhorn--Procrustes alignment with query frequencies estimated from the buffer, updated after every query. On THINGS-EEG-2, with a gallery of 200 images, it raises the top-1 accuracy on a new subject from 28% to 67% over 53 minutes of use. Across 60 evaluation settings that vary the gallery size, the query frequencies and the number of repetitions averaged per query, GALA is the most accurate label-free method in every setting, 6.6 points above the best competing method on average at the end of the stream.

Figures & tables

Appendix figures & tables8 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Aug 19, 2026

SCORE: Subject Coordinate Recovery for Label-Free Cross-Subject EEG-to-Image Retrieval

Accurate visual decoding can reveal how the brain represents visual information and recover perceived content from neural signals such as electroencephalography (EEG), with potential for neural communication. However, current EEG-to-image retrieval methods perform far below their within-subject counterparts for new users without labeled calibration, limiting real-world deployment. To understand this gap, we analyze EEG features across subjects and find that different subjects preserve similar relationships among concepts but express them along different coordinate directions. We therefore propose Subject Coordinate Recovery (SCORE), a target label-free framework combining recovery-aware source training with coordinate alignment at deployment. During training, SCORE aligns source subject EEG with a common image space and simulates unseen-subject recovery through source-only episodes. At deployment, with both encoders frozen, SCORE selects reliable EEG-image landmarks through hubness-corrected matching and estimates an orthogonal transformation to recover target EEG coordinates without source data or target labels. In 200-way retrieval on two public benchmarks, SCORE outperforms the unadapted baseline for every target subject and achieves the best overall accuracy. It reaches 53.23%/83.55% and 12.01%/32.16% Top-1/Top-5 on THINGS-EEG2 and Alljoined-1.6M, respectively, surpassing the strongest baselines by 17.45/15.70 and 3.08/4.62 percentage points. Without target labels or encoder updates, SCORE brings brain-based visual decoding closer to robust, practical, low-latency deployment across users.
Oct 5, 2026

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.
Mar 21, 2026

SATTC: Structure-Aware Label-Free Test-Time Calibration for Cross-Subject EEG-to-Image Retrieval

Cross-subject EEG-to-image retrieval for visual decoding is challenged by subject shift and hubness in the embedding space, which distort similarity geometry and destabilize top-k rankings, making small-k shortlists unreliable. We introduce SATTC (Structure-Aware Test-Time Calibration), a label-free calibration head that operates directly on the similarity matrix of frozen EEG and image encoders. SATTC combines a geometric expert, subject-adaptive whitening of EEG embeddings with an adaptive variant of Cross-domain Similarity Local Scaling (CSLS), and a structural expert built from mutual nearest neighbors, bidirectional top-k ranks, and class popularity, fused via a simple Product-of-Experts rule. On THINGS-EEG2 under a strict leave-one-subject-out protocol, standardized inference with cosine similarities, L2-normalized embeddings, and candidate whitening already yields a strong cross-subject baseline over the original ATM retrieval setup. Building on this baseline, SATTC further improves Top-1 and Top-5 accuracy, reduces hubness and per-class imbalance, and produces more reliable small-k shortlists. These gains transfer across multiple EEG encoders, supporting SATTC as an encoder-agnostic, label-free test-time calibration layer for cross-subject neural decoding.