cs.CVNov 18, 2026

NativeSeg: Native Vision Language Segmentation of 3D Computed Tomography via Spatial Visual Tokens and Verified Local Zoom

Authors: Chengqian Ma, Gaole Dai, Zijie Meng, Weixuan Jin, Yijie Du, Yuexiao Ma, Xiawu Zheng, Fei Chao

Organizations: Peking University · Tsinghua University · Institute of Automation, Chinese Academy of Sciences · Nanyang Technological University · 

Abstract

Text prompted 3D computed tomography (CT) segmentation requires both full slice context and fine boundary precision across volumes where over 80%80\% of organ prompted slices lack the queried target. Existing medical vision language models (VLMs) are largely non native segmenters: they delegate pixel delineation outside the VLM by compressing reasoning into a 1D [SEG] vector for an external Segment Anything Model (SAM) decoder, quantizing masks into lossy discrete codebooks, or issuing box prompts to stateless external SAM tools without empty slice screening or spatial state memory. We introduce NativeSeg, a native vision language segmentation framework on Low Rank Adaptation (LoRA) adapted Qwen3.8-27B that performs dense mask decoding, volumetric triage, spatial error self diagnosis, and multiround local zoom directly over the VLM's 2D spatial visual tokens without external SAM decoders. NativeSeg decodes confidence maps from upper layer 2D spatial tokens fused with a five slice U-Net pathway, halts at zero zooms on >91%>91\% of standalone evaluations via a native presence gate (<pres>), localizes uncertain boundaries via a 20 cell multiscale error gate (<err>), and accepts zoomed updates only when predicted error decreases. Trained solely on adult CT, NativeSeg improves Round 00 DSC by +19.81+19.81 and +7.04+7.04 points over discrete codebook and 1D [SEG] readouts on the identical backbone, reaches 86.81%86.81\% adult and 87.04%87.04\% zero shot pediatric DSC, and safely refines 2D nnU-Net (89.52%89.52\% adult; 86.86%86.86\% pediatric), 3D SegVol (86.81%86.81\%), and 3D VoxTell (89.85%89.85\%).

Figures & tables

Appendix figures & tables1 asset

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Mar 24, 2026

Automatic Segmentation of 3D CT scans with SAM2 using a zero-shot approach

Foundation models for image segmentation have shown strong generalization in natural images, yet their applicability to 3D medical imaging remains limited. In this work, we study the zero-shot use of Segment Anything Model 2 (SAM2) for automatic segmentation of volumetric CT data, without any fine-tuning or domain-specific training. We analyze how SAM2 should be applied to CT volumes and identify its main limitation: the lack of inherent volumetric awareness. To address this, we propose a set of inference-alone architectural and procedural modifications that adapt SAM2's video-based memory mechanism to 3D data by treating CT slices as ordered sequences. We conduct a systematic ablation study on a subset of 500 CT scans from the TotalSegmentator dataset to evaluate prompt strategies, memory propagation schemes and multi-pass refinement. Based on these findings, we select the best-performing configuration and report final results on a bigger sample of the TotalSegmentator dataset comprising 2,500 CT scans. Our results show that, even with frozen weights, SAM2 can produce coherent 3D segmentations when its inference pipeline is carefully structured, demonstrating the feasibility of a fully zero-shot approach for volumetric medical image segmentation.
Apr 9, 2026

T-Gated Adapter: A Lightweight Temporal Adapter for Vision-Language Medical Segmentation

Medical image segmentation traditionally relies on fully supervised 3D architectures that demand a large amount of dense, voxel-level annotations from clinical experts which is a prohibitively expensive process. Vision Language Models (VLMs) offer a powerful alternative by leveraging broad visual semantic representations learned from billions of images. However, when applied independently to 2D slices of a 3D scan, these models often produce noisy and anatomically implausible segmentations that violate the inherent continuity of anatomical structures. We propose a temporal adapter that addresses this by injecting adjacent-slice context directly into the model's visual token representations. The adapter comprises a temporal transformer attending across a fixed context window at the token level, a spatial context block refining within-slice representations, and an adaptive gate balancing temporal and single-slice features. Training on 30 labeled volumes from the FLARE22 dataset, our method achieves a mean Dice of 0.704 across 13 abdominal organs with a gain of +0.206 over the baseline VLM trained with no temporal context. Zero-shot evaluation on BTCV and AMOS22 datasets yields consistent improvements of +0.210 and +0.230, with the average cross-domain performance drop reducing from 38.0% to 24.9%. Furthermore, in a cross-modality evaluation on AMOS22 MRI with neither model receiving any MRI supervision, our method achieves a mean Dice of 0.366, outperforming a fully supervised 3D baseline (DynUNet, 0.224) trained exclusively on CT, suggesting that CLIP's visual semantic representations generalize more gracefully across imaging modalities than convolutional features.
Feb 18, 2026

OmniCT: Towards a Unified Slice-Volume LVLM for Comprehensive CT Analysis

Computed Tomography (CT) is one of the most widely used and diagnostically information-dense imaging modalities, covering critical organs such as the heart, lungs, liver, and colon. Clinical interpretation relies on both slice-driven local features (e.g., sub-centimeter nodules, lesion boundaries) and volume-driven spatial representations (e.g., tumor infiltration, inter-organ anatomical relations). However, existing Large Vision-Language Models (LVLMs) remain fragmented in CT slice versus volumetric understanding: slice-driven LVLMs show strong generalization but lack cross-slice spatial consistency, while volume-driven LVLMs explicitly capture volumetric semantics but suffer from coarse granularity and poor compatibility with slice inputs. The absence of a unified modeling paradigm constitutes a major bottleneck for the clinical translation of medical LVLMs. We present OmniCT, a powerful unified slice-volume LVLM for CT scenarios, which makes three contributions: (i) Spatial Consistency Enhancement (SCE): volumetric slice composition combined with tri-axial positional embedding that introduces volumetric consistency, and an MoE hybrid projection enables efficient slice-volume adaptation; (ii) Organ-level Semantic Enhancement (OSE): segmentation and ROI localization explicitly align anatomical regions, emphasizing lesion- and organ-level semantics; (iii) MedEval-CT: the largest slice-volume CT dataset and hybrid benchmark integrates comprehensive metrics for unified evaluation. OmniCT consistently outperforms existing methods with a substantial margin across diverse clinical tasks and satisfies both micro-level detail sensitivity and macro-level spatial reasoning. More importantly, it establishes a new paradigm for cross-modal medical imaging understanding. Our project is available at https://github.com/ZJU4HealthCare/OmniCT.