ConRef: Auditing Reference Reliability in 2D/3D Registration Benchmarks

Authors: Jianfeng Yue, Feng Li, Tianyu Song, Julius Watrinet, Ulrich Eck, Nassir Navab

Organizations: Chair for Computer-Aided Medical Procedures and Augmented Reality, Technical University of Munich, Munich, Germany. · Munich Center for Machine Learning, Munich, Germany. · BG Unfallklinik Murnau, Murnau am Staffelsee, Germany. · Department of Orthopaedic Sports Medicine, Technical University of Munich, Munich, Germany.

Abstract

Purpose: Accurate 2D/3D registration is crucial for image-guided orthopedic interventions, enabling the alignment of preoperative 3D anatomy with intraoperative X-ray observations for surgical navigation. Public benchmarks have facilitated the development and evaluation of increasingly accurate registration methods. However, as registration errors approach the uncertainty of benchmark reference poses, measured performance may be limited by reference inaccuracies rather than algorithmic errors alone. Methods: We propose Consensus Reference (ConRef), a multi-view framework for auditing reference poses in existing X-ray/computed tomography (CT) registration benchmarks. By jointly exploiting multiple X-ray observations, ConRef estimates an additional reference pose, quantifies its uncertainty, and identifies potential X-ray outliers. We validate the framework using independent anatomical evidence and a newly acquired X-ray/cone-beam CT (CBCT) phantom dataset with bead-based reference poses. Results: On our BeadPhant dataset, ConRef differed from independent bead-based references by 0.08-0.12 mm, while discrepancies with original references reached 2.06 mm on the Femur dataset. It also flagged 22 DeepFluoro X-rays as potential outliers. On Femur F5, reference choice changed the submillimeter success conclusions of the same registrations. Conclusion: Our findings demonstrate that reference discrepancies can influence the evaluation of high-accuracy 2D/3D registration methods. By providing an additional, independently validated reference and identifying potential inconsistencies, ConRef enables systematic auditing of existing benchmarks and supports more reliable evaluation of registration error.

Figures & tables

Appendix figures & tables2 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 24, 2026

Learning Dense 2D-3D Correspondence for X-ray-to-CT Registration of Knee Bones

Recovering the 6-DoF pose of the knee bones from a plain radiograph, given the patient's segmented pre-operative CT, turns a routine low-dose image into a quantitative measurement of joint geometry, without the added dose of a repeat CT or a fixed biplanar rig. Classic solutions align a rendered bone silhouette to image edges; recent alternatives refine pose by backpropagating an image-similarity loss through a differentiable X-ray renderer. Both operate one patient at a time and are fragile under a single view. Silhouettes are depth-ambiguous, and differentiable-rendering refinement has a narrow capture range at substantial per-iteration cost. We instead learn an amortized, subject-agnostic dense 2D-3D correspondence, supervised solely by projection geometry. One shared-weight model per bone, trained across 758 patients, registers patients unseen during training. The pose then follows in closed form from a global, initialization-free, render-free PnP+RANSAC solve. Because X-ray formation is transmissive, our correspondence target is transmission-aware rather than tied to a single surface. Though trained only to register, the representation is anatomically semantic: a simple classifier reads a landmark's anatomical region from its embedding across held-out patients, and the same features separate the knee's bones into a 2D-3D-consistent identity learned without any bone label. On a large single-institution cohort the model generalizes well to held-out patients.
Nov 3, 2026

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.
Sep 14, 2026

Benchmarking Intra-Patient 3D Deformable Multimodal Image Registration

Multimodal image registration is a key component of many clinical workflows, yet it remains challenging because corresponding anatomical structures often exhibit substantially different image intensities across modalities. In this work, we present a comprehensive benchmark of intra-patient 3D multimodal deformable registration methods across three datasets covering different anatomical regions and difficulty levels, including both synthetic deformation recovery and real clinical scenarios. We evaluate classical optimization-based approaches and modern learning-based methods, including recent deep learning and foundation models, using complementary metrics: Average Dice similarity coefficient (DSC), average 95th-percentile Hausdorff distance (HD95), and a modality-independent structural similarity measure based on the MIND self-similarity context (MIND-SSC). Results show high variability across datasets, with learning-based methods demonstrating superior performance on large synthetic benchmarks, while only limited improvements are observed in real pelvic registration. A key finding of this study is the consistent disagreement between geometric metrics (DSC, HD95) and image-based similarity metrics (MIND-SSC), highlighting that improved overlap does not necessarily imply better global multimodal correspondence. Furthermore, anatomy-guided approaches achieve the highest overlap scores but exhibit degraded performance outside of segmented regions, revealing a trade-off between label-driven alignment and global structural coherence. Overall, our results indicate that no current method achieves robust performance across anatomies and modalities. We demonstrate that intra-patient 3D multimodal registration requires multi-criteria evaluation, including deformation-based metrics, and remains an open problem.