cs.LGNov 20, 2026

Multi-Tier Edge Triage: Optimizing Latency for Safe Clinical Agents

Authors: Joshua Broyde, Sarita A. Joshi

Organizations: Google Cloud

Abstract

Deploying generative AI agents in enterprise clinical workflows requires enforcing multi-dimensional safety and compliance policies--preventing HIPAA Protected Health Information (PHI) exposure, maintaining clinical scope-of-practice boundaries, ensuring patient-appropriate reading comprehension, and preserving brand integrity--under interactive latency constraints. Synchronous outbound calls to cloud Large Language Model (LLM) judges add substantial network and decoding overhead onto the critical response path. We present Multi-Tier Edge Triage, a safety screening architecture that co-locates a compact Tier-1 sequence classifier on the clinical agent's host server, resolving clear queries in-process without a network round-trip and escalating only ambiguous queries to a Tier-2 cloud LLM judge. To evaluate Tier-1 encoders without length or unigram shortcuts, we construct four length-matched contrastive twin benchmarks seeded from MedSafetyBench, ASQ-PHI, and a synthetic four-mandate clinical assistant policy (Generic HealthCorp). While frozen local encoders match cloud models on structured PHI detection (>= 98.3% accuracy in <= 23.5 ms), they degrade markedly on semantic safety and symmetric-blocklist prompts. However, end-to-end representation fine-tuning closes the multi-policy accuracy gap: a fine-tuned 335M-parameter BGE-Large classifier achieves 98.90% out-of-fold accuracy versus 99.20% for a zero-shot cloud LLM judge (exact McNemar p = 0.648, zero shared errors), 97.8%-98.2% recall, and a 0.0%-0.4% over-refusal rate in 39.0 ms (>14x faster than cloud LLM evaluation on our benchmark host). Per-policy error analysis reveals ceiling local recall on PHI (100.0%), brand (100.0%), and clinical scope (98.7%-99.3%) violations, isolating residual errors to reading-level checks (93.3%-95.3%) and motivating targeted multi-tier escalation.

Figures & tables

Appendix figures & tables8 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 7, 2026

CareGuardAI: Context-Aware Multi-Agent Guardrails for Clinical Safety & Hallucination Mitigation in Patient-Facing LLMs

Integrating large language models (LLMs) into patient-facing healthcare systems offers significant potential to improve access to medical information. However, ensuring clinical safety and factual reliability remains a critical challenge. In practice, AI-generated responses may be conditionally correct yet medically inappropriate, as models often fail to interpret patient context and tend to produce agreeable responses rather than challenge unsafe assumptions. Unlike clinicians, who infer risk from incomplete information, LLMs frequently lack contextual awareness. Moreover, real-world patient interactions are open-ended and underspecified, unlike structured benchmark settings. We present CareGuardAI, a risk-aware safety framework for patient-facing medical question answering that addresses two key failure modes: clinical safety risk and hallucination risk. The framework introduces Clinical Safety Risk Assessment (SRA), inspired by ISO 14971, and Hallucination Risk Assessment (HRA) to evaluate medical risk and factual reliability. At inference time, CareGuardAI employs a multi-stage pipeline consisting of a controller agent, safety-constrained generation, and dual risk evaluation, followed by iterative refinement when necessary. Responses are released only when both SRA and HRA are less than or equal to 2, ensuring clinically acceptable outputs with bounded latency. We evaluate CareGuardAI on PatientSafeBench, MedSafetyBench, and MedHallu, covering both safety and hallucination detection. Across these benchmarks, the framework consistently outperforms strong baseline models, including GPT-4o-mini, demonstrating the importance of context-aware, risk-based, inference-time safety mechanisms for reliable deployment in healthcare.
Nov 17, 2026

Beyond Acuity Accuracy: A Multidimensional Framework for Evaluating Patient-Facing Emergency Triage AI Tools

Patient-facing AI triage tools may support care-seeking and emergency department prioritization, but require evaluation beyond acuity accuracy alone. We developed SAFE-Triage, a framework integrating human review, automated metrics, LLM-as-judge evaluation, and simulation testing across clinical performance, patient interaction, and clinician-facing summary quality. We applied SAFE-Triage to 40 MIMIC-IV-derived emergency vignettes and a 10,030-case acuity analysis comparing prompted LLM triage (PLT) with rule-augmented prompted LLM triage (rPLT). PLT achieved higher emergency severity index (ESI) accuracy (57.5% vs 42.8%, P<0.001P < 0.001), lower undertriage (13.1% vs 29.8%, P<0.001P < 0.001), and higher clinician ratings across all domains. rPLT produced shorter and more stable outputs with higher automated readability scores. SAFE-Triage identified trade-offs between acuity accuracy, undertriage risk, communication quality, readability, and summary quality, supporting pre-deployment refinement and ongoing monitoring by showing where triage tools are efficient, need improvement, or need clinician oversight.
Aug 4, 2026

CARE-Bench: Benchmarking Patient-Facing LLM Triage

Patient-facing medical LLMs and agents increasingly answer symptom questions before clinician contact, where the key safety question is what action the user should take next. We introduce CARE-Bench, a source-grounded benchmark that evaluates sequential patient-facing triage as a four-label per-turn current-action task. CARE-Bench contains 500 cases and 1,059 evaluated patient-disclosure prefixes reconstructed from medical dialogue, consultation, and follow-up-question sources. We evaluate 11 models on 269 held-out rounds under unprompted and minimally prompted open-ended protocols, using a fixed GPT-5.5 mapper to code each response into the four-label action space. Unprompted macro-F1 remains low, ranging from 31.2 to 50.4. Prompting improves 10 of 11 models, with prompted macro-F1 ranging from 46.9 to 63.4, but substantial threshold errors remain. Prompted models often recommend care before needed clarification is obtained; when the correct action was to ask for more information, only 33.5% of prompted outputs preserved the step. The persistence of these errors after prompting suggests that patient-facing triage is not a simple prompting problem and supports explicit evaluation of action timing before deployment.