Organizations: School of Biomedical Engineering, Tsinghua Medicine, Tsinghua University, Beijing, China · Department of Radiology, West China Second University Hospital, Sichuan University, Chengdu, China · Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
Unsupervised anomaly detection (UAD) offers a promising approach to fetal brain magnetic resonance imaging (MRI) analysis, where pathological data are scarce. Existing methods rely mainly on brain age prediction or image reconstruction, but are limited by noisy gestational age (GA) labels, lack of lesion localization, or poor cross-domain generalization. We propose FetalBUAD, a UAD framework based on voxel-level brain age estimation. A joint multi-task network predicts global brain age, voxel-level brain age maps, and brain segmentation to establish an internal biological brain age reference, reducing reliance on clinically recorded GA. Uncertainty-aware voxel-level brain age gap maps are then used for anomaly localization. Experiments on 1,317 internal fetal brain MRI volumes and an external benchmark demonstrate state-of-the-art anomaly detection performance and improved cross-domain generalization. FetalBUAD also generates anatomically interpretable maps that localize diverse fetal brain abnormalities. Our code is publicly available at: https://github.com/birthlab/FetalBUAD.
Figures & tables
Fig. 1: Overview of FetalBUAD. (a) Joint multi-task training: A shared encoder-decoder network predicts global brain age, voxel-level brain age, and brain segmentation from normal fetal brain MRIs. Noise perturbation of voxel-level targets encourages local morphological learning, while segmentation provides anatomical constraints. (b) Inference and anomaly detection: Monte Carlo Dropout estimates predictive means and epistemic uncertainty for global and voxel-level age predictions. The bias-corrected global age serves as the biological reference, and the voxel-level brain age gap is weighted by normalized uncertainty to generate the final anomaly map.
Method
AUROC
AUPR
Sensitivity
Specificity
Internal Test Dataset: Abnormal ( n= 110) & Normal ( n= 606)
Single-slice AAD † [ 8 ]
0.656 [0.595, 0.713]
0.340 [0.254, 0.432]
0.436 [0.333, 0.532]
0.340 [0.257, 0.412]
Multi-slice AAD † [ 9 ]
0.596 [0.528, 0.657]
0.280 [0.208, 0.364]
0.355 [0.272, 0.450]
0.188 [0.102, 0.398]
Whole-brain AAD † [ 10 ]
0.584 [0.522, 0.643]
0.269 [0.193, 0.350]
0.318 [0.213, 0.420]
0.252 [0.209, 0.342]
PANDA † [ 11 ]
0.726 [0.674, 0.781]
0.441 [0.355, 0.533]
0.564 [0.467, 0.656]
0.465 [0.346, 0.611]
3D AE ‡ [ 15 ]
0.740 [0.688, 0.789]
0.392 [0.297, 0.482]
0.509 [0.409, 0.621]
0.502 [0.367, 0.666]
3D DAE ‡ [ 16 ]
0.630 [0.571, 0.690]
0.285 [0.210, 0.366]
0.400 [0.287, 0.496]
0.304 [0.213, 0.443]
TABLE I: Comparison of case-level anomaly detection performance on the internal test set and external test set. AUROC and AUPR are reported together with sensitivity at a fixed specificity of 0.80 and specificity at a fixed sensitivity of 0.80. Symbols indicate method categories: † brain age prediction-based methods; ‡ reconstruction-based methods. Best in blue , runner-up in green .
Fig. 2: Lesion localization in representative normal and pathological cases from the internal test set. Yellow dashed boxes indicate ground-truth lesions. Pathological findings include corpus callosum agenesis in ACC, posterior fossa cystic dilation and cerebellar hypoplasia in DWM, and hypointense hemorrhagic regions in GMH-IVH. Rows show anomaly maps from reconstruction-based baselines (3D AE, 3D DAE, 3D STFPM, and IterMask3D) and the proposed FetalBUAD.
Method
AUROC
AUPR
Sensitivity
Specificity
Internal Test Dataset: Abnormal ( n= 110) & Normal ( n= 606)
w/o registration to 38w
0.870 [0.827, 0.911]
0.718 [0.638, 0.794]
0.809 [0.720, 0.877]
0.802 [0.662, 0.878]
w/o segmentation task
0.829 [0.786, 0.870]
0.616 [0.529, 0.697]
0.655 [0.561, 0.762]
0.652 [0.503, 0.779]
w/o uncertainty-weighted
0.887 [0.849, 0.920]
0.737 [0.665, 0.804]
0.800 [0.722, 0.868]
0.759 [0.625, 0.887]
Metric: mean
0.881 [0.843, 0.914]
0.711 [0.636, 0.778]
0.755 [0.675, 0.841]
0.748 [0.643, 0.862]
FetalBUAD
0.905 [0.870, 0.935]
0.764 [0.694, 0.828]
0.845 [0.750, 0.907]
0.868 [0.715, 0.919]
TABLE II: Ablation study on the internal test set. AUROC and AUPR are reported together with sensitivity at a fixed specificity of 0.80 and specificity at a fixed sensitivity of 0.80. Best in blue , runner-up in green .
Unsupervised anomaly detection (UAD) methods for brain MRI are ranked by a single score, yet that score rests on choices that are rarely reported: how each anomaly map is aligned with the reference, how and on which data the threshold is set, and which false-positive budget, metric, aggregation and lesion definition are used. We present MIRTO, an evaluation protocol that makes these choices explicit and measures their effect. It gates the geometry of every comparison with a registration check and label-free diagnostics of known power, sets thresholds on validation data alone and reports the false-positive volume actually realised on test, repeats each comparison over 15,552 defensible evaluation pipelines, and attaches paired subject-bootstrap intervals with multiplicity control. Applied to four UAD methods trained on the same healthy data and tested on 312 BraTS 2020 subjects, MIRTO showed that an axis-order mismatch between stored maps and the reference lowered a diffusion model's voxel AUROC from 0.873 to 0.583 whilst barely moving its slice-level AUROC. Within each metric, the method explained at least 0.95 of the variance in voxel AUROC and AUPRC and 0.77 in Dice, but only 0.14 in lesion sensitivity, where the lesion definition and hit criterion dominated. A Dice advantage that was significant at validation thresholds vanished at equal realised false-positive burden, and an exact identity attributes it to threshold transfer. A training-free change to REFLECT's latent aggregation raised Dice at equal burden by 0.052. Nine hypotheses were tested against explicit criteria; because the same cohort served to develop the protocol, all inference is exploratory.
Negin Kafee Hernashki, Soumick Chatterjee
Università degli Studi di Milano, Milan, Italy · Politecnico di Milano, Milan, Italy · Human Technopole, Milan, Italy +1
Unsupervised anomaly detection (UAD) aims to localize abnormal regions in medical scans without pixel-level annotations. A typical strategy seeks to reconstruct a pseudo-healthy image that preserves subject-specific anatomy. Recently, diffusion models have been proposed to perform UAD. However, these methods rely on heuristic noise schedules or synthetic corruptions to balance subject-specificity and anomaly removal. In this work, we propose an alternative formulation of UAD as a Bayesian inverse problem under a diffusion prior. First, we introduce a latent spatial anomaly mask that models pixel-wise consistency between a test image and its latent corresponding pseudo-healthy image. Then, we propose an approximation of the unknown generation process that links healthy anatomy, anomalies, and the observed image, enabling a well-defined likelihood within the Bayesian framework. Building on recent advances in diffusion-based inverse problem methods, we jointly infer the pseudo-healthy image and the anomaly mask via annealed posterior sampling. We evaluate our approach on FDG PET (ADNI) and FLAIR MRI (BraTS 2021), demonstrating improved anomaly localization performance compared to other diffusion-based approaches and validating the contribution of our introduced model. Our code is available at https://github.com/HuguesRoy/UAD_DAPS.
Hugues Roy, Reuben Dorent, Ninon Burgos
Sorbonne Université, Institut du Cerveau - Paris Brain Institute - ICM, CNRS, Inria, Inserm, AP-HP, Hôpital de la Pitié Salpêtrière, F-75013, Paris, France
Fetal brain biometry is essential for quantitative assessment of brain development, supporting gestational age estimation, developmental monitoring, and detection of abnormalities. In clinical practice, measurements are manually performed, making them time-consuming and prone to variability. While automated approaches have been proposed, reproducible methods remain limited, particularly those providing anatomically interpretable landmark localization. We present a fully automated deep learning-based framework for reliable and reproducible brain biometry from 3D super-resolution-reconstructed fetal brain MRI. The proposed four-step pipeline derives biometric parameters by jointly estimating linear measurements and their corresponding anatomical landmarks. A 3D convolutional neural network is trained to regress landmark coordinates from brain segmentation label maps, followed by measurement-specific geometric optimization to refine landmark positions and compute measurements. The pipeline is evaluated on two publicly available fetal MRI datasets comprising 150 volumes (gestational age range: 20-37 weeks) acquired across different scanners and protocols, assessing five key biometric measurements across varying acquisition settings and providing a comprehensive evaluation of both measurement accuracy and landmark localization using quantitative metrics and visual assessment. Compared with the only available automated pipeline, the proposed method achieves comparable or improved accuracy for most measurements. In conclusion, we introduce a straightforward pipeline for reliable biometry estimations, with efficiency, interpretability and scalability that support integration into clinical workflows.
Francesca Maccarone, Marina Di Stefano, Giorgio Longari +7
NeuroImaging Laboratory, Scientific Institute IRCCS Eugenio Medea, Bosisio Parini (LC), Italy · University of Milano-Bicocca, Milan, Italy · Image Sciences Institute, Division Imaging and Oncology, University Medical Center Utrecht, Utrecht, The Netherlands