cs.CVNov 22, 2026

GAG-Net: Graph-Based Anatomical Guidance Network for Pharyngeal Area Segmentation in VFSS Images

Authors: JunYeong Park, Myung Woo Park, Byung Chan Lee, Hyung Jin Chang, Sang-Il Choi

Organizations: Department of AI-based Convergence, Dankook University, Yongin, Republic of Korea · Department of Rehabilitation Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Republic of Korea · Department of Rehabilitation Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea · Department of Physical Medicine and Rehabilitation, Chung-Ang University Hospital, Seoul, Republic of Korea · 

Abstract

Diagnosing sarcopenic dysphagia typically requires costly supplementary imaging such as CT or MRI to assess muscle atrophy, burdening elderly patients. The pharyngeal area at rest (PA_rest), measurable directly from videofluoroscopic swallowing study (VFSS) images, is a promising biomarker that could eliminate this dependency, but repeated manual measurement has limited its adoption. PA_rest segmentation is further complicated by indistinct soft-tissue boundaries and clinical rule-based delineation criteria that data-driven models capture only imprecisely. We formulate automated PA_rest segmentation as a clinically defined measurement task, translating an implicit clinical measurement into an explicit landmark specification and annotation protocol developed with a rehabilitation medicine specialist. Applying this protocol, we constructed, to our knowledge, the first dataset for this task: 2,255 single-center VFSS frames from 137 patients, with PA_rest contours and seven landmarks verified by a senior specialist. We then introduce GAG-Net, an automated rest-frame measurement pipeline combining deformable convolutions, for irregular pharyngeal boundaries, with a graph-based anatomical guidance module that models the geometric dependencies among landmarks prescribed by the delineation rules. On a patient-level held-out test set (237 frames, 67 patients), GAG-Net achieved the lowest area measurement error (mean absolute percentage error: 8.17% against specialist-verified references; patient-level ICC 0.97) and the highest Dice score (0.8862) among all evaluated methods, with 67.2% fewer parameters and 74% less training memory than the two-stage JOINED model. Integrating clinician-defined anatomical knowledge may enable automated PA_rest measurement from VFSS images alone, supporting quantitative assessment of sarcopenic dysphagia without supplementary imaging.

Explore similar work

Oct 6, 2026

Structure-aware Keypoint Localization for Videofluoroscopic Swallowing Study

Videofluoroscopic Swallowing Study (VFSS) is one of the gold standard for diagnosing swallowing disorders, providing dynamic X-ray imaging of the swallowing process. Automated kinematic analysis in VFSS relies fundamentally on precise anatomical keypoint localization. However, existing studies focus on limited keypoints (e.g., cervical vertebrae or the hyoid) and overlook critical regions such as the soft palate, while annotating only active swallowing segments and ignoring abundant non-swallowing data, resulting in poor data efficiency. Moreover, leveraging this unlabeled data via standard semi-supervised learning is suboptimal, as generic methods are prone to spatial bias. In medical X-rays with fixed layouts, models tend to memorize absolute coordinates rather than understanding anatomical structures. To tackle these challenges, we introduce VFSSKep, a novel dataset that extends annotations to the soft palate and incorporates large-scale unlabeled data. We further propose S3^3KL, a Structure-aware Semi-Supervised Keypoint Localization framework designed to overcome spatial bias. It integrates a Structure-Aware Learning strategy to extract high-resolution structural cues for structure-aware representation learning, and a Structural Representation Consistency Learning strategy with block shuffling to enforce invariant structural recognition. Experiments show our method achieves state-of-the-art semi-supervised performance, even with unlabeled and 25% labeled data surpassing fully supervised learning with 100% labeled data. Code and data will be made publicly available at: https://github.com/kaai520/S3KL.
Oct 27, 2026

Effects of Deep Learning Architecture and Pretraining on Automated Vocal Fold Segmentation in Ex Vivo High-Speed Phonation Images

Two-dimensional (2D) intraglottal particle image velocimetry (PIV) of ex vivo phonation experiments quantifies vocal fold medial surface dynamics and the intraglottal flow field. However, it relies on manual segmentation because residual glare, low tissue-to-flow contrast, and tracer-particle speckle obscure the vocal fold boundaries. This study assessed how deep learning architecture and ImageNet pretraining affect automated vocal fold segmentation in these high-speed images. Four established architectures from three categories were benchmarked: the convolutional neural network (CNN)-based UNet and UNet++, the hybrid CNN-transformer-based TransUNet, and the pure transformer-based Swin-UNet, the latter two trained from scratch and from ImageNet-pretrained weights. Using 16,344 expert-annotated images from 227 phonation trials of excised canine larynges, the six pipelines were trained with five seeds under a standardized protocol and compared on 50 held-out test trials using trial-level Wilcoxon signed-rank tests with Holm correction. Mean Dice similarity coefficient (DSC) spanned only 0.9734 to 0.9764, so the pipelines differed mainly in boundary fidelity. Pretraining significantly improved the boundary F1 score (BF1) and 95th percentile Hausdorff distance (HD95) of the TransUNet and Swin-UNet, about four times more for the Swin-UNet. Once pretrained, the two performed similarly, although the Swin-UNet has only about a quarter of the trainable parameters. Without pretraining, the TransUNet had a significantly higher BF1 and a lower HD95 than both CNN-based pipelines and about half their share of images with HD95 > 50 pixels. To our knowledge, this is the first study to apply deep learning to vocal fold segmentation in 2D intraglottal PIV, and it offers a reference framework for segmenting experimental flow-visualization images with noisy optical conditions or highly deformable objects.
Mar 2, 2026

A Detection-Gated Pipeline for Robust Glottal Area Waveform Extraction and Clinical Pathology Assessment

We present a fully automated, two-stage modular glottal area segmentation framework for high-speed videoendoscopy (HSV) designed for accuracy, generalizability, and real-time playback. Our detection-gated pipeline combines a YOLOv8n glottis localizer with a U-Net segmenter; the localizer defines a tight crop to ensure a consistent field of view and gates the output to reduce spurious segmentations during glottal closure. The models were trained on the GIRAFE (N=600) and BAGLS (N=55,750) datasets. Cross-dataset portability was evaluated by benchmarking GIRAFE-trained models on the BAGLS test set without fine-tuning. In these evaluations, the pipeline achieved a Dice Similarity Coefficient (DSC) of 0.745 (87% of the in-domain ceiling). On in-distribution test sets, the system achieved DSCs of 0.81 (GIRAFE) and 0.856 (BAGLS), outperforming or competing with state-of-the-art methods. An exploratory clinical study of 40 subjects demonstrated that the glottal area Coefficient of Variation (CV distinguished healthy from pathological function (p=0.006). The system processes ~35 frames per second on commodity hardware, enabling interactive clinical review. This design supports uniform extraction of laryngeal kinematic measures across varying acquisition settings. Code, weights, and software are available at https://github.com/hari-krishnan/openglottal.