Organizations: Department of Psychological and Cognitive Sciences, Tsinghua University, Beijing, China · State Key Laboratory of Virtual Reality Technology and Systems, Beihang University, Beijing, China · Zhongguancun Laboratory, Beijing, China
Hand pose estimation aims to recover the spatial configuration of hand joints from visual observations and serves as a fundamental perception module for downstream systems that rely on complete and topologically consistent hand representations. Most existing methods are developed under the assumption of fully articulated hand structures and tend to produce unstable or implausible predictions when parts of the kinematic structure are persistently absent, resulting in degraded performance or even system failure despite available partial observations. To study this challenge, we construct IncNYU, a physiologically constrained benchmark that simulates structural incompleteness through morphological modification of complete hand models and retains reference locations for both intact and synthetically removed regions. Based on this benchmark, we propose InsHaPE, an Inclusive Hand Pose Estimation framework designed to remain robust under structural incompleteness while preserving performance on standard, fully articulated hands. Built on hierarchical kinematic modeling, InsHaPE introduces two complementary components. First, a topology-aware distillation strategy transfers joint-level and relational priors from fully articulated hand representations, providing anatomically consistent initialization under missing structures. Second, a progressive kinematic reasoning module performs structured inference along the kinematic chain, enabling complete and anatomically consistent pose estimation under severe structural variations. Extensive experiments on NYU/IncNYU, together with external validation on MSRA, demonstrate that InsHaPE improves robustness under structural incompleteness while maintaining competitive performance on complete hands. System-level evaluations further show that InsHaPE improves robustness for downstream applications that require fixed-topology hand pose representations.
Figures & tables
Fig. 1 : System-level comparison between a representative baseline method [ 9 ] and the proposed InsHaPE framework under standard and structurally incomplete settings. (a) The baseline method produces erroneous or implausible joint predictions when parts of the hand structure are missing. (b) In contrast, InsHaPE maintains topologically consistent and complete pose estimation under the same conditions. (c) Quantitative comparison of pose estimation accuracy (MPJPE) on NYU and IncNYU, where the baseline exhibits a substantial performance degradation (from 7.12 to 11.49 MPJPE), while InsHaPE shows only a marginal increase (from 7.07 to 8.00). (d) Gesture recognition accuracy under complete-hand and simulated-incomplete observation conditions, where InsHaPE outperforms the baseline in both settings (74.2% vs. 60.9%, and 56.7% vs. 45.1%) and the arrows indicate the relative accuracy drop from the complete to the incomplete setting. (e) Subjective usability scores reported by participants in a controlled system-level evaluation, reflecting improved reliability and compatibility of InsHaPE with downstream applications that require fixed-topology hand pose representations.
Fig. 2 : Comparison of three hand pose modeling paradigms. (a) Flat joint-wise modeling, where all joints share a single parameterization and are regressed independently. (b) Cascaded (finger-wise) modeling, which performs part-level cascaded prediction across the palm and fingers but lacks explicit intra-finger kinematic hierarchy. (c) Our hierarchical kinematic modeling, which conducts progressive root-to-tip inference and explicitly encodes kinematic dependencies, enabling robust pose estimation under structural incompleteness.
Fig. 3 : IncNYU construction pipeline. Unlike mask-based occlusion augmentation, we simulate finger amputations in 3D by removing MANO mesh segments according to anatomical rules and render the resulting incomplete hands as depth images.
Fig. 4 : Framework overview. 4 Appearance features are extracted from the input depth image. 4 Geometric point-cloud features are obtained from valid depth pixels through 2D-to-3D back-projection. 4 Topology-aware distillation transfers structural priors from complete hand structures. 4 Progressive kinematic reasoning performs hierarchical root-to-tip inference for complete pose estimation. and denote trainable and frozen backbones during topology-aware distillation, respectively.
Method
Venue
Input
MPJPE
Ren-9x6x6 [ 60 ]
JVCI’18
D
12.69
DeepPrior++ [ 61 ]
ICCV’17
D
12.24
Pose-Ren [ 62 ]
NEUCOM’20
D
11.81
DenseReg [ 2 ]
CVPR’18
D
10.20
CrossInfoNet [ 27 ]
CVPR’19
D
10.08
A2J [ 63 ]
ICCV’19
D
8.61
TABLE I : Performance comparison with state-of-the-art methods on the NYU dataset. The cyan cell marks the best result. Input modalities include 2D depth images (D), 3D voxels (V), and 3D point clouds (P).
Method
Venue
Input
w/o IncNYU retraining
Ecom
Einc
Eavg
A2J [ 63 ]
ICCV’19
D
82.58
91.85
87.28
AWR [ 64 ]
AAAI’20
D
67.44
94.16
73.72
TriHorn-Net [ 56 ]
ESWA’23
D
15.59
46.79
22.07
HandR2N2 [ 53 ]
ICCV’23
P
16.25
26.36
19.23
IPNet [ 10 ]
AAAI’23
D+P
20.49
35.36
23.65
TABLE II : Performance comparison with state-of-the-art methods on the IncNYU dataset. A cyan cell marks the best result in each column. Input modalities include 2D depth images (D), 3D voxels (V), and 3D point clouds (P).
Method
Venue
Input
MSRA
MSRA → IncMSRA
IncMSRA
IPNet [ 10 ]
AAAI’23
D+P
6.64
7.18
7.36
HandDiff [ 11 ]
CVPR’24
D+P
6.53
6.90
5.89
HandDAGT [ 9 ]
ECCV’24
D+P
6.38
6.79
6.74
InsHaPE (Ours)
–
D+P
5.52
6.23
5.77
TABLE III : Performance comparison on MSRA and IncMSRA. We report MPJPE (mm) on standard MSRA, direct generalization from MSRA to IncMSRA without re-training, and performance after re-training on IncMSRA.
Method
Params (M)
FLOPs (G)
Inference (ms)
Eavg
IPNet [ 10 ]
39.51
2.97
45.65
12.36
HandDiff [ 11 ]
67.55
46.68
59.75
15.99
HandDAGT [ 9 ]
69.48
23.74
45.47
11.49
InsHaPE w/ 1 stack s (Ours)
74.20
17.09
18.12
10.67
InsHaPE w/ 2 stacks (Ours)
91.10
20.42
23.44
8.10
InsHaPE w/ 3 stacks (Ours)
108.01
23.47
29.43
8.00
TABLE IV : Computational comparison on the IncNYU dataset.
ID
Configuration
Ecom
Einc
Eavg
TAD
PKR*
GLI
1
✔
✔
✔
5.80
13.75
8.00
2
✔
✔
✗
5.93 ↑2%
13.88 ↑1%
8.15 ↑2%
3
✔
✗
✗
5.77 ≈0%
14.15 ↑3%
8.18 ↑2%
4
✗
✔
✔
6.94 ↑20%
13.84 ↑1%
9.56 ↑20%
5
✗
✔
✗
8.16 ↑41%
16.31 ↑19%
10.95 ↑37%
TABLE V : Core module ablation results on IncNYU. Reported percentages indicate relative error changes compared to the full model (ID 1). TAD : Topology-Aware Distillation (§ IV-B ); PKR* : Progressive Kinematic Reasoning (§ IV-C ) without Global–Local Interaction (GLI, Eq. 15 ).
ID
Configuration
Ecom
Einc
Eavg
Lglobal
Ljoint
Ltopo
1
✔
✔
✔
5.80
13.75
8.00
2
✔
✔
✗
6.72 ↑16%
14.20 ↑3%
8.81 ↑10%
3
✔
✗
✗
7.66 ↑32%
16.69 ↑21%
10.27 ↑28%
4
✗
✔
✔
5.97 ↑3%
14.00 ↑2%
8.27 ↑3%
5
✗
✔
✗
6.19 ↑7%
14.10 ↑3%
8.41 ↑5%
TABLE VI : Distillation loss ablation results on IncNYU. Reported percentages are error changes compared to ID 1.
Fig. 5 : Ablation results of different hand pose modeling paradigms (see Fig. 2 ). We compare flat joint-wise modeling, cascaded finger-wise modeling, and the proposed hierarchical root-to-tip reasoning in terms of (a) Ecom , (b) Einc , and (c) Eavg .
Configuration
Ecom
Einc
Eavg
InsHaPE (Full model)
5.83 ± 0.04
13.55 ± 0.35
8.01 ± 0.10
w/o Parent Conditioning
5.86 ± 0.05
14.08 ± 0.28
8.13 ± 0.08
TABLE VII : Parent-conditioning control on IncNYU (mean ± standard deviation over three matched random seeds).
Configuration
Ecom
Einc
Eavg
InsHaPE (Full model)
5.80
13.75
8.00
w/o Point Cloud
9.34 ↑61%
16.71 ↑22%
11.35 ↑42%
TABLE VIII : Geometric point-cloud ablation on IncNYU.
Fig. 6 : Joint-wise error analysis on the IncNYU dataset. 6 : Mean per-joint position error (MPJPE), showing increasing difficulty from palm to fingertips. 6 : PCK-style curves illustrating the fraction of frames within a given distance threshold to the ground truth (GT).
Configuration
Ecom
Einc
Eavg
HandDiff
13.76
25.57
15.99
HandDiff + Paired Supervision
9.87
↓28%
16.93
↓34%
12.29
↓23%
InsHaPE (Ours)
5.80
13.75
8.00
TABLE IX : Comparison under paired supervision on IncNYU.
Hyperparameter
0.005
0.01
0.05
0.1
λ1
8.14
8.00
8.29
8.47
λ2
8.18
8.12
8.00
8.32
α
8.07
8.00
8.14
8.18
β
8.11
8.00
8.15
8.23
TABLE X : Sensitivity analysis of loss-related hyperparameters on IncNYU. We report Eavg under different values of each hyperparameter, while keeping the other hyperparameters fixed at their default settings. The best result in each row is highlighted in bold.
Fig. 7 : Qualitative comparisons of InsHaPE with state-of-the-art baselines on the IncNYU dataset. Circles mark highlighted parts.
Fig. 8 : One-dimensional loss-landscape slices on IncNYU. InsHaPE exhibits a flatter loss profile than the compared methods along the sampled, filter-normalized perturbation directions.
Fig. 9 : Temporal error variation analysis on IncNYU. (a) Frame-wise MPJPE across the inferred pseudo-continuous segments, with the mean trend and SEM. (b–c) Threshold-based cumulative distributions of the first-order error variation and second-order error fluctuation, respectively; curves closer to the upper-left indicate smaller variation of the scalar error. (d–f) Representative pseudo-continuous segments from low-, medium-, and high-error regimes, respectively.
Fig. 10 : Prototype MR system powered by InsHaPE. (a) Hand pose estimation and interaction pipeline. (b–c) Representative interaction scenarios under structurally incomplete hand configurations. Please refer to the supplementary video for full demonstrations.
Fig. 11 : Controlled simulation of persistent missing observations using a light-sensitive finger mask. (a) Experimental setup. (b) HandDAGT [ 9 ] produces erroneous and implausible skeleton predictions under simulated incompleteness. (c) InsHaPE maintains more plausible and anatomically consistent skeleton estimation.
Fig. 12 : Results of the controlled user study with simulated persistent incompleteness. (a–b) Gesture recognition accuracy under complete-hand and simulated incomplete-hand conditions for InsHaPE and HandDAGT, respectively. (c) Subjective ratings of perceived naturalness, ease of interaction, and reliability on a 7-point Likert scale. Bars show means, error bars denote standard errors of the means, and *** in (c) denotes p<0.001 under paired tests of the ratings.
Participant
Recog. Acc.
Naturalness
Ease of Inter.
Reliability
Baseline
Ours
Baseline
Ours
Baseline
Ours
Baseline
Ours
P1
48.0
64.0
5
6
5
6
4
6
P2
44.0
60.0
4
6
4
6
4
5
P3
40.0
52.0
4
5
4
5
3
5
Mean
44.0
58.7
4.33
5.67
4.33
5.67
3.67
5.33
TABLE XI : Pilot evaluation on three participants with real finger incompleteness. We report gesture recognition accuracy (%) and subjective ratings on naturalness, ease of interaction, and reliability under the same downstream MR protocol as the controlled study.
Fig. 13 : Representative results from the real incomplete-hand pilot study for a participant with partial thumb amputation. (a–b) Open-palm gesture estimated by InsHaPE and the HandDAGT baseline, respectively. (c–d) Thumb-up gesture estimated by InsHaPE and the HandDAGT baseline, respectively. In these trials, the downstream recognizer succeeds with InsHaPE and fails with the baseline.