Remote photoplethysmography (rPPG) enables contactless physiological monitoring from facial videos, but facial motion, particularly mouth and jaw movements during cognitive and communicative tasks, can severely degrade signal reconstruction. We present SKIA, a lightweight, mask-guided framework that suppresses motion-prone lower-face regions while preserving physiological cues from the forehead and cheeks. Using the UBFC-rPPG benchmark, we first investigate static lower-face suppression in the classical CHROM pipeline. Static masking improves waveform Pearson correlation from 0.3507 to 0.4166 (p < 0.001) and reduces heart-rate mean absolute error (MAE) from 33.50 to 23.44 bpm. Building on this finding, we introduce SKIA-Net, a compact spatiotemporal architecture that combines raw facial frames, statically masked representations, and temporal motion differences to reconstruct blood volume pulse (BVP) waveforms. The full model achieves a Pearson correlation of 0.7522 and a heart-rate MAE of 3.73 bpm on UBFC-rPPG, outperforming single-stream variants. Ablation studies show that the static mask provides complementary information to raw appearance and that static anatomical priors outperform the tested dynamic optical-flow-based masking strategy. These results suggest that spatially informed, temporally stable masking can improve motion-robust rPPG estimation. Code: https://github.com/lee-vtruong/SKIA-rPPG
Figures & tables
Figure 1: Example of static lower-face suppression. The lower facial region is removed while preserving relatively stable physiological regions such as the forehead and cheeks.
Figure 2: Overview of SKIA. Raw frames, static lower-face suppressed frames, and temporal-difference frames are jointly encoded to reconstruct the target BVP waveform.
Variant
Raw
Masked
Temporal diff.
SKIA Raw
✓
SKIA Masked
✓
SKIA Raw+Masked
✓
✓
SKIA Full
✓
✓
✓
Table 1: SKIA-Net variants and input configurations.
Parameter
Value
Optimizer
Adam
Learning rate
1×10−4
Batch size
4
Clip length
64 / 128
Input size
96 × 96 / 128 × 128
Loss
Negative Pearson Loss
Table 2: Main implementation settings.
Method
Pearson ↑
HR MAE ↓
CHROM
0.3507
33.50
CHROM + Static Mask
0.4166
23.44
Table 3: CHROM performance with and without static lower-face suppression.
Method
Pearson ↑
HR MAE ↓
PhysNet-lite [ 17 ]
0.2350
–
SKIA Raw
0.6320
8.99
SKIA Masked
0.6246
7.55
SKIA Raw+Masked
0.6844
4.97
SKIA Full
0.7522
3.73
Table 4: Comparison between SKIA-Net variants.
Ratio
Mean Δ Pearson
Winrate
0.5
-0.0210
40.5%
0.6
+0.0592
81.0%
0.7
+0.0659
88.1%
0.8
+0.0410
85.7%
Table 5: Ablation study on lower-face suppression ratio.
Method
Pearson ↑
Δ vs CHROM
Winrate
CHROM Baseline
0.3507
–
–
Static Mask
0.4166
+0.0659
88.1%
Dynamic Soft Mask
0.1534
-0.1973
4.8%
Table 6: Static and dynamic masking strategies.
Figure 3: Frequency-domain comparison between baseline CHROM and static lower-face suppression for Subject 42.
Method
FPS
CHROM
568.73
CHROM + Static Mask
305.63
SKIA Raw
4868.11
SKIA Raw+Masked
17523.12
SKIA Full
10626.73
Table 7: Runtime throughput comparison.
Figure 4: Qualitative visualization of SKIA-Net reconstruction. Top: original frame, static lower-face mask, and masked frame. Bottom: reconstructed BVP waveform compared with ground-truth physiological signal.
Remote photoplethysmography (rPPG) estimates physiological signals from facial videos by analyzing subtle pulse induced skin color variations. Despite recent progress, existing self-supervised rPPG methods mainly reconstruct masked pixels or low-level visual representations, which can bias the model toward facial appearance rather than latent physiological dy namics. Moreover, most recent Mamba-based approaches scan facial video tokens only in chronological order, limiting their ability to exploit the cyclic structure of pulse signals. To ad dress these limitations, we propose RhythmJEPA, a rhythm structured joint-embedding predictive learning framework for rPPG. Instead of reconstructing RGB frames, RhythmJEPA predicts latent teacher representations from masked facial videos, thereby encouraging physiology-aware representation learning in the embedding space. To explicitly model pulse-related tem poral structure, we introduce a Cyclic Rhythm-State Plan ner (CRSP), which estimates frame-wise latent physiological states and decodes the most plausible cyclic state path via dynamic programming with a constrained transition grammar. Guided by the decoded states, we further design a Dual Order Mamba Encoder (DOM), which combines conventional chronological scanning with state-ordered scanning to capture both local temporal continuity and long-range rhythm-consistent dependencies. Finally, a lightweight Spatial Pulse Mixer (SPM) extracts compact pulse-sensitive facial tokens with a favorable balance between complexity and performance. Experiments on PURE, UBFC-rPPG, and MMPD show competitive performance over representative rPPG methods. The codes are available at https://github.com/deconasser/RhythmJEPA.
Remote photoplethysmography (rPPG) enables non-contact heart rate measurement from facial videos, but its performance is significantly degraded by facial motions such as speaking and head shaking. To address this issue, we propose two plug-and-play modules. The Angle-guided ROI Adaptive Optimization module quantifies ROI-Camera angles to refine motion-affected signals and capture global motion, while the Multi-region Joint Graph Signal Denoising module jointly models intra- and inter-regional ROI signals using graph signal processing to suppress motion artifacts. The modules are compatible with reflection model-based rPPG methods and validated on three public datasets. Results show that jointly use markedly reduces MAE, with an average decrease of 20.38% over the baseline, while ablation studies confirm the effectiveness of each module. The work demonstrates the potential of angle-guided optimization and graph-based denoising to enhance rPPG performance in motion scenarios.
Gan Pei, Junhao Ning, Boqiu Shen +2
Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University · Shanghai Changzheng Hospital, Naval Military Medical University · Chongqing Key Laboratory of Precision Optics, Chongqing Institute of East China Normal University
Remote photoplethysmography (rPPG) enables contactless physiological monitoring by capturing subtle skin-color variations from facial videos. However, most existing methods predominantly rely on time-domain modeling, making them vulnerable to motion artifacts and illumination fluctuations, where weak physiological clues are easily overwhelmed by noise. To address these challenges, we propose FreqPhys, a frequency-guided rPPG framework that explicitly leverages physiological frequency priors for robust signal recovery. Specifically, FreqPhys first applies a Physiological Bandpass Filtering module to suppress out-of-band interference, and then performs Physiological Spectrum Modulation together with adaptive spectral selection to emphasize pulse-related frequency components while suppress residual in-band noise. A Cross-domain Representation Learning module further fuses these spectral priors with deep time-domain features to capture informative spatial--temporal dependencies. Finally, a frequency-aware conditional diffusion process progressively reconstructs high-fidelity rPPG signals. Extensive experiments on six benchmarks demonstrate that FreqPhys yields significant improvements over state-of-the-art approaches, particularly under challenging motion conditions. It highlights the importance of explicitly modeling physiological frequency priors. The source code will be released.
Wei Qian, Dan Guo, Jinxing Zhou +3
Hefei University of Technology · Hefei Comprehensive National Science Center · MBZUAI +2