cs.LGNov 22, 2026

Hybrid state-space and attention neural operators for nonlinear structural dynamics under environmental loading

Authors: Anastasios Stamou, Rui Teixeira, Maria Nogal, Michalis Fragiadakis

Organizations: National Technical University of Athens, 9 Iroon Polytechniou, Zografou Campus, Athens, 15780, Greece. · Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, Delft, 2628 CN, The Netherlands. · Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, Museum Building, College Green, Dublin 2, D02 PN40, Ireland.

Abstract

The computational burden of repeated nonlinear time-history analyses limits their application for structural assessment and design. We therefore propose DeepOJamba, a hybrid neural operator that combines selective state-space recurrence with full attention to predict the structural response history due to dynamic loading. Physical-parameter conditioning and predicted-state transfer between sequences enable a single trained operator to represent varying system conditions and generate response histories beyond its training sequence length. DeepOJamba is evaluated on a 15~MW monopile offshore wind turbine under wind and wave loading. The proposed operator is compared to pure attention, pure state-space, Fourier, and DeepONet operators and is found to give the lowest window error on every channel and the lowest closed-loop fatigue and ultimate-load errors of 9.4%9.4\% and 6.0%6.0\%, against 14.6%14.6\% and 8.7%8.7\% for the next-best pure attention operator examined. Moreover, on sea states outside the training wave band, the error slightly increases by approximately 0.40.4 percentage points. Pure state-space operators can approach similar low errors only with a much wider convolution kernel tuned to the tower eigenperiod, which increases the training cost by 40%40\%. In all, the results obtained support hybrid neural operators for robust long-duration structural response and demand prediction.

Figures & tables

Appendix figures & tables19 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 1, 2026

Equation-Free Digital Twins for Nonlinear Structural Dynamics

Monitoring floating offshore wind turbines (FOWTs) under stochastic excitation and sensor failure requires computationally efficient and physically interpretable estimators. This paper introduces an equation-free, output-only digital twin framework combining Hankel dynamic mode decomposition (Hankel-DMD), sparse-sensor reconstruction, and a stochastic Kalman extension. A sufficient identifiability condition is derived for modal amplitudes recovered from delay-embedded measurements, while Tikhonov regularization addresses ill-conditioned sensor layouts. Correlation-domain identification improves damping estimates under stochastic forcing and distinguishes structural modes from rotor harmonics. The framework is validated using OpenFAST simulations of an NREL 5-MW spar turbine and experimental basin-test measurements from a 1:70-scale IEA 15-MW semi-submersible. In simulations, the identified tower modes agree with established operational modal analysis methods (MAC at least 0.99), while the Kalman estimator achieves R-squared values of 0.91 to 0.99 under severe sensor sparsity. Experimental results identify tower modes at 0.430 and 0.415 Hz with MAC of 1.00 against SSI-COV and reconstruct tower-base bending moments on unseen runs with R-squared values of 0.83 to 0.89 using three of four sensors. The framework provides a computationally efficient, sensor-failure-resilient structural-state estimation layer for digital twins.
Mar 10, 2026

A neural operator for predicting vibration frequency response curves from limited data

In the design of engineered components, rigorous vibration testing is essential for performance validation and identification of resonant frequencies and amplitudes encountered during operation. Performing this evaluation numerically via machine learning has great potential to accelerate design iteration and make testing workflows more efficient. However, dynamical systems are conventionally difficult to solve via machine learning methods without using physics-based regularizing loss functions. To properly perform this forecasting task, a structure that has an inspectable physical obedience can be devised without the use of regularizing terms from first principles. The method employed in this work is a neural operator integrated with an implicit numerical scheme. This architecture enables operators to learn of the underlying state-space dynamics from limited data, allowing generalization to untested driving frequencies and initial conditions. This network can infer the system's global frequency response by training on a small set of input conditions. As a foundational proof of concept, this investigation verifies the machine learning algorithm with a linear, single-degree-of-freedom system, demonstrating implicit obedience of dynamics. This approach demonstrates 99.87% accuracy in predicting the Frequency Response Curve (FRC), forecasting the frequency and amplitude of linear resonance training on 7% of the bandwidth of the solution. By training machine learning models to internalize physics information rather than trajectory, better generalization accuracy can be realized, vastly improving the timeframe for vibration studies on engineered components.
Apr 2, 2026

Transformer self-attention encoder-decoder with multimodal deep learning for response time series forecasting and digital twin support in wind structural health monitoring

The wind-induced structural response forecasting capabilities of a novel transformer methodology are examined here. The model also provides a digital twin component for bridge structural health monitoring. Firstly, the approach uses the temporal characteristics of the system to train a forecasting model. Secondly, the vibration predictions are compared to the measured ones to detect large deviations. Finally, the identified cases are used as an early-warning indicator of structural change. The artificial intelligence-based model outperforms approaches for response forecasting as no assumption on wind stationarity or on structural normal vibration behavior is needed. Specifically, wind-excited dynamic behavior suffers from uncertainty related to obtaining poor predictions when the environmental or traffic conditions change. This results in a hard distinction of what constitutes normal vibration behavior. To this end, a framework is rigorously examined on real-world measurements from the Hardanger Bridge monitored by the Norwegian University of Science and Technology. The approach captures accurate structural behavior in realistic conditions, and with respect to the changes in the system excitation. The results, importantly, highlight the potential of transformer-based digital twin components to serve as next-generation tools for resilient infrastructure management, continuous learning, and adaptive monitoring over the system's lifecycle with respect to temporal characteristics.