Organizations: School of Biomedical Engineering, Division of Life Sciences and Medicine, USTC · MIRACLE Lab, Suzhou Institute for Advance Research, USTC · Jiangsu Key Laboratory of Multimodal Digital Twin Technology, Suzhou, Jiangsu, China 215123 · The University of Texas at Austin
Current MLLM methods largely focus on whether models attend to the right visual regions, implicitly treating spatial attention map as the primary key of effective visual perception. To examine this assumption, we introduce a medical VQA dataset with paired non-contrast (NC) and contrast-enhanced (CE) images that share corresponding anatomy while providing different cues. We show that this view is incomplete: across paired NC and CE medical images, MLLMs often exhibit similar attention patterns despite producing contrasting answers, while controlled bidirectional interventions induce substantially larger prediction changes on visual values than attention weights. These results identify the visual content retrieved through values as a critical factor in improving perception beyond spatial attention alone. Guided by this finding, we propose VIVID (VIsual Value Intervention Distillation), which uses enhanced visual values to identify and refine teacher corrections aligned with useful visual evidence to improve on-policy distillation from CE to NC images. Across six internal and external test sets, VIVID consistently outperforms existing on-policy distillation methods across different model scales and architectures, requires only NC images at inference, and maintains strong zero-shot performance on general-domain VQA benchmarks. The project page is available at https://qiuzyc.github.io/VIVID.
Figures & tables
Figure 1: Visual values improve predictions more than attention maps. (a) [M] determines where to read, while [V] provides what is read. (b) Paired NC and CE images yield similar attention maps but different answers. (c) CE-to-NC interventions compare transferring [M] versus [V] , with larger gains from [V] under both single-layer and all-layer replacement.
Figure 2: Similar attention map, different answers. Paired NC and CE scans from liver, brain, and breast cases. In each example, the model exhibits similar attention patterns but answers incorrectly from the NC scan and correctly from the CE scan.
Figure 3: Layer-wise attention patterns on liver CT. Blue and purple curves show the fraction of attention weight allocated to image tokens for NC and CE inputs (left axis). The orange curve shows cosine similarity between their visual attention maps (right axis). Shaded bands indicate 95% confidence intervals.
Model
Swap
ΔPGT
Δ Acc.
CE → NC
NC → CE
CE → NC
NC → CE
Qwen3-VL
[M]
+1.39
-1.61
+22.36
-8.02
[V]
+5.46
-4.72
+37.55
-24.89
Δ
+4.07
-3.11
+15.19
-16.87
MedGemma
[M]
+1.82
-0.76
+34.76
-12.30
[V]
+3.69
-4.67
+57.75
-32.09
Table 1: Paired [M] and [V] exchanges on liver CT. [M] and [V] denote spatial attention weights and visual values. Results are reported in percentage points. Arrows indicate donor-to-recipient transfer. Red Δ entries report [V] minus [M] .
[M]
[V]
Noise on [M]
Qwen3-VL
MedGemma
ΔPGT
Δ Acc.
ΔPGT
Δ Acc.
CE
NC
0%
+1.39
+22.36
+1.82
+34.76
NC
CE
0%
+5.46
+37.55
+3.69
+57.75
NC
CE
25%
+4.66
+34.60
+3.64
+54.55
NC
CE
50%
+3.81
+32.07
+3.44
+49.20
Table 2: Value transfer under attention perturbations on liver CT. All interventions are applied to the NC branch. The first two columns specify the sources of attention weights [M] and visual values [V] ; noise is applied only to [M] . Changes relative to the original NC predictions are reported in percentage points.
Figure 4: Overview of VIVID. All branches share prefixes from the non-contrast student’s rollouts. An auxiliary branch mixes paired enhanced-image values into attention-weight-selected visual positions. The induced prediction shift guides a positive projection of the teacher’s correction in centered log-probability space to construct the distillation target.
Model / Method
Param.
Liver Cancer
Brain Cancer
Breast Cancer
Average
Internal
External
Internal
External
Internal
External
Internal
External
General Off-the-Shelf MLLMs
GPT-5.6 Luna [ 38 ]
–
50.72
44.90
46.98
47.06
47.52
47.04
48.41
46.33
Gemini 3.5 Flash [ 16 ]
–
54.26
51.82
68.24
67.14
64.01
57.65
62.17
58.87
DeepSeek-V4.1-Flash [ 9 ]
552B
44.54
53.58
55.25
55.41
53.05
49.63
50.95
52.87
Qwen3.8-Flash [ 42 ]
–
49.43
51.23
53.38
53.64
48.27
47.38
50.36
50.75
Table 3: Comparison with general and medical MLLMs and on-policy distillation baselines on internal and external test sets. “+” denotes further training from SFT. Gray-shaded Average columns report separate unweighted means across the three internal and external test sets. Best and second-best available results within each Qwen3-VL block are bold and underlined , respectively. Double underlines identify the best available off-the-shelf result in each column across general and medical MLLMs. Δ reports Ours minus the best-performing off-the-shelf MLLM in each column, considering both general and medical models, with red indicating improvement and blue indicating decline.
Method
InternVL3-2B [ 58 ]
MedGemma-4B [ 46 ]
Internal
External
Internal
External
Zero-shot
42.65
34.82
43.86
37.16
SFT
65.26
52.17
70.61
54.51
+ OPSD
64.81
53.22
66.84
52.40
+ VIVID
66.54
54.04
70.76
59.91
Table 4: Evaluation across MLLM architectures on liver CT dataset. OPSD and our method further train the SFT model. Best and second-best results are bold and underlined , respectively.
Method
VQA-RAD
SLAKE
PMC-VQA
ChartQA
Average
Qwen3-VL-2B
SFT
62.50
68.75
47.10
76.88
63.81
+ OPSD
62.87
68.27
46.75
76.96
63.71
+ VIVID
63.24
68.99
47.50
78.56
64.57
Qwen3-VL-4B
SFT
63.97
74.04
51.25
81.92
67.80
Table 5: Cross-benchmark generalization on medical and general VQAs. OPSD and our method further train the SFT model. Avg. denotes the unweighted mean accuracy across four benchmarks. Best and second-best results are bold and underlined , respectively.
Variant
Qwen3-VL-2B
Qwen3-VL-4B
Internal
External
Internal
External
Random Reg.
65.71
49.82
71.14
56.51
Alt. Attn.
64.73
51.47
71.06
54.28
w/o Proj.
66.24
51.70
70.99
57.33
VIVID
66.47
52.64
71.29
57.91
Table 6: Ablation study across Qwen3-VL on the liver CT dataset. Best and second-best results are bold and underlined , respectively.
Metric
Qwen3-VL-2B
Qwen3-VL-4B
SFT
OPSD
VIVID
SFT
OPSD
VIVID
MS(pp) ↑
4.92
4.99
6.64
1.21
1.22
2.45
NLL ↓
1.53
1.64
1.34
0.87
0.91
0.85
PGTerr(%)↑
6.45
6.23
8.21
13.89
12.09
14.75
Table 7: Predictive-distribution analysis on liver CT dataset. Best and second-best values within each model scale are bold and underlined , respectively.
Figure 5: Visual representation improvement relative to OPSD on liver CT dataset. Blue and purple denote Qwen3-VL-2B and 4B. Percentage changes relative to OPSD are grouped by decoder depth: (a–d) increased cosine similarity and reduced ℓ2 distance to the enhanced-image reference for visual values and fixed-attention readouts; (e) increased top-ten explained variance; (f) reduced effective rank. Reductions are plotted as positive values.
Appendix figures & tables29 assets
Supplementary material from the paper’s appendix.
Appendix
Source cohort
Train
Int. Test
Ext. Test
Total
Liver CT
MCT-LTDiag
450
50
0
500
TriALS
0
0
44
44
Brain MRI
UPENN-GBM
361
42
0
403
UCSF-PDGM
242
21
0
263
Appendix
Table 8: Patient counts by source cohort and split. Int. and Ext. denote internal and external, respectively.
Figure 6: Prompt template for evidence generation. [DATASET NAME] is replaced with the corresponding dataset name.
Figure 7: Representative examples of our dataset. From left to right: lesion identification, lesion characterization, and multi-region localization.
Score
Assessment criteria
5
All spatial references are correct and clearly identify the location or region relevant to the question.
4
Spatial references are correct and unambiguous, with only minor wording imprecision that does not affect localization.
3
The intended location remains identifiable, but localized errors, omissions, or ambiguous references require substantive clarification.
2
A major error in anatomical location, laterality, region identity, or inside/outside assignment prevents reliable localization, although some spatial details remain correct.
1
Spatial references predominantly identify the wrong site or region, contradict the annotations, or fail to establish an interpretable location.
Appendix
Table 9: Five-point rubric for spatial consistency. Ratings assess anatomical location, laterality, region identifiers, and inside/outside relations against the supplied annotations.
Score
Assessment criteria
5
All claims are medically accurate, supported by the supplied information, and relevant to the question. The evidence clearly supports the reference answer without unsupported findings or unjustified certainty.
4
The evidence accurately supports the reference answer, with only minor wording imprecision or redundancy and no substantive factual errors.
3
Non-critical factual errors, omissions, or insufficient explanation weaken answer support, but the core finding remains correct.
2
Major errors or unsupported inferences concerning lesion presence, multiplicity, composition, or appearance undermine answer support, although some valid information remains.
1
The central description contradicts the supplied facts or reference answer, reverses the key finding, or consists predominantly of unsupported claims.
Appendix
Table 10: Five-point rubric for factual accuracy and answer support. Ratings assess medical correctness, grounding in the supplied facts and images, and support for the reference answer.
Dataset
Train
Int. test
Ext. test
Total
Liver
450 / 11778
50 / 1327
44 / 853
544 / 13958
Brain
976 / 29282
108 / 3265
167 / 4981
1251 / 37528
Breast
1292 / 28840
144 / 3201
64 / 1471
1500 / 33512
Total
2718 / 69900
302 / 7793
275 / 7305
3295 / 84998
Appendix
Table 11: Dataset statistics. Patient / question counts for training, internal testing, and external testing. Each question is counted once across paired NC–CE views.
Figure 8: Layer-wise attention patterns on the brain MRI dataset. Solid curves show NC and CE image-attention ratios (left axis); dashed curves show foreground cosine similarity (right axis). Shading denotes 95% confidence intervals.
Figure 9: Layer-wise attention patterns on the breast MRI dataset. Curves and confidence intervals follow Figure 8
Dataset
Swap
ΔPGT
Δ Acc.
CE → NC
NC → CE
CE → NC
NC → CE
Liver CT
[M]
-0.55
+1.92
-26.47
+19.12
[V]
-4.51
+5.58
-42.65
+36.76
Δ
-3.96
+3.66
-16.18
+17.65
Brain MRI
[M]
-1.00
+0.96
-13.96
+20.05
[V]
-2.69
+4.36
-19.29
+25.38
Appendix
Table 12: Paired [M] and [V] exchanges with Qwen3-VL-4B on the reverse subset. Results are evaluated on NC-correct/CE-incorrect pairs. All-layer changes are reported in percentage points. Arrows indicate donor-to-recipient transfer; red Δ entries report [V] minus [M] .
Dataset
[M]
[V]
Noise on [M]
ΔPGT
Δ Acc.
Liver CT
CE
NC
0%
-0.55
-26.47
NC
CE
0%
-4.51
-42.65
NC
CE
25%
-3.23
-35.29
NC
CE
50%
-1.97
-23.53
Brain MRI
CE
NC
0%
-1.00
-13.96
NC
CE
0%
-2.69
-19.29
Appendix
Table 13: Value transfer under attention noise with Qwen3-VL-4B on the reverse subset. Evaluation subsets follow Table 12 . Interventions affect all decoder layers in the NC branch, with noise added only to [M] . Changes are reported in percentage points. Bold entries mark value transfer without attention noise.
Model
Swap
ΔPGT
Δ Acc.
CE → NC
NC → CE
CE → NC
NC → CE
Qwen3-VL
[M]
+3.85
-1.51
+15.78
-6.92
[V]
+8.42
-3.05
+26.57
-10.79
Δ
+4.57
-1.54
+10.79
-3.86
MedGemma
[M]
+7.18
-3.35
+22.26
-11.50
[V]
+12.06
-6.18
+46.17
-22.45
Appendix
Table 14: Paired [M] and [V] exchanges on brain MRI. Changes are reported in percentage points. Arrows indicate donor-to-recipient transfer; red Δ entries report [V] minus [M] .
[M]
[V]
Noise on [M]
Qwen3-VL
MedGemma
ΔPGT
Δ Acc.
ΔPGT
Δ Acc.
CE
NC
0%
+3.85
+15.78
+7.18
+22.26
NC
CE
0%
+8.42
+26.57
+12.06
+46.17
NC
CE
25%
+7.84
+24.80
+12.38
+45.26
NC
CE
50%
+7.46
+24.64
+12.68
+43.25
Appendix
Table 15: Value transfer under attention perturbations on brain MRI. Sources of [M] and [V] are listed in the first two columns. Noise affects only [M] in the NC branch. Changes from original NC predictions are reported in percentage points.
Model
Swap
ΔPGT
Δ Acc.
CE → NC
NC → CE
CE → NC
NC → CE
Qwen3-VL
[M]
+3.31
-2.89
+14.68
-13.21
[V]
+7.57
-6.81
+41.65
-24.95
Δ
+4.27
-3.92
+26.97
-11.74
MedGemma
[M]
+6.22
-3.74
+21.22
-9.23
[V]
+8.99
-7.23
+54.61
-32.47
Appendix
Table 16: Paired [M] and [V] exchanges on breast MRI. Changes are reported in percentage points. Arrows indicate donor-to-recipient transfer; red Δ entries report [V] minus [M] .
[M]
[V]
Noise on [M]
Qwen3-VL
MedGemma
ΔPGT
Δ Acc.
ΔPGT
Δ Acc.
CE
NC
0%
+3.31
+14.68
+6.22
+21.22
NC
CE
0%
+7.57
+41.65
+8.99
+54.61
NC
CE
25%
+7.58
+36.15
+8.95
+51.29
NC
CE
50%
+7.41
+32.84
+8.99
+44.28
Appendix
Table 17: Value transfer under attention perturbations on breast MRI. Sources of [M] and [V] are listed in the first two columns. Noise affects only [M] in the NC branch. Changes from original NC predictions are reported in percentage points.
Figure 10: Layer-wise effects of attention and value interventions. On NC-incorrect/CE-correct pairs, CE spatial attention weights [M] or visual values [V] are transferred to the NC branch at one decoder layer at a time. Curves report changes in reference-answer probability and accuracy relative to the original NC predictions, in percentage points. Noise is applied only to attention weights during value transfer.
Model
Swap
ΔPGT
Δ Acc.
CE → NC
NC → CE
CE → NC
NC → CE
Qwen3-VL
[M]
+1.07
-1.25
+21.21
-10.77
[V]
+4.53
-3.30
+33.00
-19.87
Δ
+3.45
-2.05
+11.78
-9.09
Appendix
Table 18: Paired [M] and [V] exchanges between separately trained models on liver CT. Both branches are Qwen3-VL-4B models independently fine-tuned on NC or CE images. Results are reported in percentage points. Arrows indicate donor-to-recipient transfer. Red Δ entries report [V] minus [M] .
Metric
CE [M]
CE [V]
No noise
No noise
25% noise
50% noise
ΔPGT
+1.07
+4.53
+4.13
+3.72
Δ Acc.
+21.21
+33.00
+30.98
+28.28
Appendix
Table 19: Value transfer under attention perturbations. Results use separately trained Qwen3-VL-4B models on liver CT. Changes relative to the NC baseline are reported in percentage points. Noise is applied to NC attention during CE value transfer.
Configuration
SFT
On-policy Distillation
Image Input
Image size
512×512
512×512
LoRA
Rank / alpha
64 / 128
64 / 128
Dropout
0.05
0.05
Target modules
Decoder linear
Decoder linear
Appendix
Table 20: Training configurations for MLLMs. SFT uses combined NC and CE data; On-policy Distillation methods use NC rollouts with a frozen CE teacher.
Test set
OPSD
Med-OPD
VA-OPD
VIVID
Internal
62.59 ± 1.59
64.56 ± 0.28
62.80 ± 0.46
66.54 ± 0.35
External
46.62 ± 1.06
47.13 ± 0.59
46.23 ± 0.48
52.17 ± 0.47
Appendix
Table 21: Across-seed performance on the liver CT dataset with Qwen3-VL-2B. We report mean accuracy ± standard deviation on the full internal and external test sets. Best and second-best results are bold and underlined , respectively.
Method
Qwen3-VL-2B
Qwen3-VL-4B
Internal
External
Internal
External
Lesion Identification (2 options)
OPSD
72.30
54.32
77.50
64.61
Med-OPD
72.04
52.47
78.67
62.96
VA-OPD
71.26
52.88
78.80
64.20
VIVID
74.90
61.93
79.06
66.87
Appendix
Table 22: Liver CT dataset results by option count and question category. Accuracy (%) on internal and external test sets. Best and second-best results are bold and underlined, respectively.
Scale
Method
Training
Inference
s/step
GiB
s/question
GiB
2B
Med-OPD
86.10
19.88
1.44
4.07
VA-OPD
73.49
16.35
1.53
4.07
VIVID
47.46
30.31
1.53
4.07
4B
Med-OPD
85.38
44.94
1.71
8.44
VA-OPD
91.94
35.30
1.86
8.44
Appendix
Table 23: Computational efficiency using NVIDIA H20 GPUs. Training reports historical mean step time and peak Actor allocated memory; batch configurations and retained response counts differ across runs. Inference reports mean latency at batch size one. Memory excludes separately hosted teacher processes.
Variant
Qwen3-VL-2B
Qwen3-VL-4B
Internal
External
Internal
External
Attention Coverage
τ=0.25
65.56
50.88
70.99
56.39
τ=0.75
66.16
51.82
70.91
57.44
Value Mixing Ratio
α=0.25
66.31
52.52
71.14
56.62
Appendix
Table 24: Hyperparameter and objective sensitivity on liver CT. Each variant changes one setting from the default VIVID configuration. τ denotes foreground attention coverage, α the CE value mixing ratio, λ the weak teacher-supervision coefficient, and K the vocabulary support size excluding the retained tail bucket. Accuracy is reported in percentages, with the best result in each column shown in bold .
Dataset
Early
Middle
Late
Overall
Qwen3-VL-2B
Liver CT
14.68
9.68
9.10
11.08
Brain MRI
18.37
14.92
15.07
16.08
Breast MRI
10.84
10.04
8.58
9.78
Qwen3-VL-4B
Liver CT
14.82
8.49
6.63
9.98
Appendix
Table 25: Attention-guided patch selection. Values report selected patches as a percentage of non-background patches. Early, Middle, and Late summarize the corresponding layer groups; Overall aggregates across all layers.
Dataset
Cosine
Positive (%)
Retained (%)
Qwen3-VL-2B
Liver CT
0.224
83.61
24.54
Brain MRI
0.208
82.13
23.53
Breast MRI
0.247
85.02
26.81
Qwen3-VL-4B
Liver CT
0.197
80.43
22.23
Appendix
Table 26: Response-guided projection statistics. Cosine reports mean cosine similarity between the teacher-correction and auxiliary-response directions. Positive reports the percentage of generation positions with a nonzero positive projection. Retained norm reports the mean ratio ∥d∥2/∥r∥2 as a percentage, where r is the full teacher correction and d its positive projection, including positions with zero projection.
Figure 11: Spatial distribution of patches selected for value mixing. Rows show liver CT, brain MRI, and breast MRI examples; columns illustrate lesion identification, lesion characterization, and local visual discrimination. Each example presents the NC image (left) and its patch-selection heatmap (right), followed by the question and VIVID’s predicted answer. Heatmaps aggregate selection frequencies across decoder layers and generation positions under τ=0.5 ; brighter colors indicate more frequent selection. Red boxes denote queried or candidate regions, and numbered lesion labels provide spatial references.
Score
Assessment criteria
5
Core facts agree with the reference, with no substantive contradictions. Paraphrases and omissions that do not affect the factual meaning are acceptable.
4
Core facts agree, but minor details are omitted, descriptions are less precise, or additional details cannot be verified from the reference.
3
The evidence partially agrees with the reference but omits key information, is too vague to establish the main finding, or introduces substantial unsupported details.
2
The evidence substantively contradicts the reference regarding lesion presence, multiplicity, composition, location, candidate regions, or important imaging characteristics.
1
The core facts are predominantly opposite to the reference, the content is irrelevant, or no usable evidence is provided.
Appendix
Table 27: Five-point rubric for generated evidence correctness. Ratings assess factual agreement with the reference evidence, including lesion presence, attributes, location, and candidate-region relationships. Semantically equivalent wording is accepted.
Score
Assessment criteria
5
The evidence clearly and sufficiently supports the predicted answer, with no internal contradictions.
4
The evidence generally supports the predicted answer, but contains a minor reasoning gap or an imprecise statement of scope.
3
The evidence is compatible with the predicted answer but is too vague or incomplete to distinguish it from alternative options.
2
The evidence mainly supports another answer or contains a substantial contradiction, although some support for the predicted answer remains.
1
The evidence directly contradicts the predicted answer, or no usable evidence is provided.
Appendix
Table 28: Five-point rubric for evidence–answer consistency. Ratings assess whether the generated evidence supports the model’s own predicted answer, independently of reference correctness. Reference answers and evidence are not shown during this assessment.
Dataset
SFT
OPSD
Med-OPD
VA-OPD
VIVID
Liver
4.01±1.10
4.03±1.10
4.06±1.00
4.05±1.02
4.17±0.89
Brain
4.72±0.64
4.65±0.61
4.68±0.60
4.68±0.60
4.74±0.58
Breast
4.16±0.93
4.14±0.94
4.14±0.90
4.10±0.95
4.18±0.94
Appendix
Table 29: Correctness of model-generated evidence. Scores are reported as mean ± standard deviation. Higher is better; the highest mean score for each dataset is shown in bold .
Figure 12: Qualitative comparisons of SFT, OPSD, and VIVID across three datasets. Examples show model-generated evidence and answers for liver CT, brain MRI, and breast MRI. Checkmarks and crosses indicate correct and incorrect answers, respectively. Margin selectivity is reported alongside each response, and top-1–top-2 probability margins are shown for highlighted evidence tokens, both in percentage points. VIVID corrects baseline errors and exhibits higher margin selectivity in these examples. Even when methods produce the same correct answer, VIVID assigns a larger probability margin to the highlighted answer-relevant token.
Medical visual question answering (Med-VQA) aims to answer clinically relevant questions grounded in medical images. However, existing multimodal large language models (MLLMs) often exhibit shortcut answering, producing plausible responses by exploiting language priors or dataset biases while insufficiently attending to visual evidence. This behavior undermines clinical reliability, especially when subtle imaging findings are decisive. We propose a lightweight plug-in framework, termed Intent-aware Visual Cues (InViC), to explicitly enhance image-based answer generation in medical VQA. InViC introduces a Cue Tokens Extraction (CTE) module that distills dense visual tokens into a compact set of K question-conditioned cue tokens, which serve as structured visual intermediaries injected into the LLM decoder to promote intent-aligned visual evidence. To discourage bypassing of visual information, we further design a two-stage fine-tuning strategy with a cue-bottleneck attention mask. In Stage I, we employ an attention mask to block the LLM's direct view of raw visual features, thereby funneling all visual evidence through the cue pathway. In Stage II, standard causal attention is restored to train the LLM to jointly exploit the visual and cue tokens. We evaluate InViC on three public Med-VQA benchmarks (VQA-RAD, SLAKE, and ImageCLEF VQA-Med 2019) across multiple representative MLLMs. InViC consistently improves over zero-shot inference and standard LoRA fine-tuning, demonstrating that intent-aware visual cues with bottlenecked training is a practical and effective strategy for improving trustworthy Med-VQA.
Zhisong Wang, Ziyang Chen, Zanting Ye +3
National Engineering Laboratory for Integrated Aero-Space-Ground-Ocean Big Data Application Technology, School of Computer Science and Engineering, Northwestern Polytechnical University, Xi’an 710072, China · Southern Medical University · Westlake University
Medical vision--language models (VLMs) have shown strong potential for medical visual question answering (VQA), yet their reasoning remains largely text-centric: images are encoded once as static context, and subsequent inference is dominated by language. This paradigm is fundamentally limited in clinical scenarios, where accurate answers often depend on subtle, localized visual evidence that cannot be reliably preserved in static embeddings. We propose MedLVR, a latent visual reasoning framework that introduces an explicit visual evidence state into autoregressive decoding. Instead of relying solely on text-based intermediate reasoning, MedLVR interleaves a short latent reasoning segment within the decoder by reusing hidden states as continuous latent steps, enabling iterative preservation and refinement of query-relevant visual evidence before answer generation. To support effective visual supervision, we adopt a two-stage training strategy: region of interest (ROI)-supervised fine-tuning aligns latent states with clinically relevant image evidence, and Visual-Latent Policy Optimization (VLPO) further optimizes latent reasoning and answer generation under outcome-level rewards. Experiments on OmniMedVQA and five external medical VQA benchmarks show that MedLVR consistently outperforms recent reasoning baselines and improves the average score over the Qwen2.5-VL-7B backbone from 48.3% to 53.4%. These results show that latent visual reasoning provides an effective mechanism for preserving diagnostically relevant visual evidence and improving the reliability of medical VQA.
Suyang Xi, Songtao Hu, Yuxiang Lai +4
Department of Radiation Oncology and Winship Cancer Institute, Emory University School of Medicine, Atlanta, 30322, GA, USA · Department of Biostatistics and Bioinformatics, Emory University, Atlanta, 30322, GA, USA
Thinking with Images improves fine-grained VQA for MLLMs by emphasizing visual cues. However, tool-augmented methods depend on the capacity of grounding, which remains unreliable for MLLMs. In parallel, attention-driven methods to crop the Region of Interest (ROIs) are proposed but they are constrained by (1) fragmented attention signals scattered across layers, leading to suboptimal localization and (2) relying on question- or redundant-text-conditioned attention extraction. Our analysis reveals three patterns: MLLMs may attend to the correct region yet generate incorrect coordinates, where-to-look attention is often fragmented across layers, and attention extraction is query-sensitive. Motivated by these, We propose ConFoThinking, a Consolidated-Focused-Attention-Driven Thinking framework that learns to aggregate attention into a designated intermediate layer, from which we mine and zoom in salient regions for downstream visual understanding. Moreover, we extract attention using concise semantic cues of what to look into, which mitigates the semantic noise introduced by question- or redundant-text-based attention extraction. Experiments across five VQA benchmarks demonstrate ConFoThinking significantly improves perception performance. The code, checkpoints, and dataset will be released after being accepted.
Zhaodong Wu, Haochen Xue, Qi Cao +5
Wangxuan Institute of Computer Technology, Peking University, Beijing, China · School of AI and Advanced Computing, Xi’an Jiaotong-Liverpool University, Suzhou, China