Beyond Attention Maps: Understanding and Improving Medical MLLMs via Visual Values
Organizations: School of Biomedical Engineering, Division of Life Sciences and Medicine, USTC · MIRACLE Lab, Suzhou Institute for Advance Research, USTC · Jiangsu Key Laboratory of Multimodal Digital Twin Technology, Suzhou, Jiangsu, China 215123 · The University of Texas at Austin
Abstract
Current MLLM methods largely focus on whether models attend to the right visual regions, implicitly treating spatial attention map as the primary key of effective visual perception. To examine this assumption, we introduce a medical VQA dataset with paired non-contrast (NC) and contrast-enhanced (CE) images that share corresponding anatomy while providing different cues. We show that this view is incomplete: across paired NC and CE medical images, MLLMs often exhibit similar attention patterns despite producing contrasting answers, while controlled bidirectional interventions induce substantially larger prediction changes on visual values than attention weights. These results identify the visual content retrieved through values as a critical factor in improving perception beyond spatial attention alone. Guided by this finding, we propose VIVID (VIsual Value Intervention Distillation), which uses enhanced visual values to identify and refine teacher corrections aligned with useful visual evidence to improve on-policy distillation from CE to NC images. Across six internal and external test sets, VIVID consistently outperforms existing on-policy distillation methods across different model scales and architectures, requires only NC images at inference, and maintains strong zero-shot performance on general-domain VQA benchmarks. The project page is available at https://qiuzyc.github.io/VIVID.
Figures & tables
| Model | Swap | Acc. | |||
| CE NC | NC CE | CE NC | NC CE | ||
| Qwen3-VL | [M] | +1.39 | -1.61 | +22.36 | -8.02 |
| [V] | +5.46 | -4.72 | +37.55 | -24.89 | |
| +4.07 | -3.11 | +15.19 | -16.87 | ||
| MedGemma | [M] | +1.82 | -0.76 | +34.76 | -12.30 |
| [V] | +3.69 | -4.67 | +57.75 | -32.09 | |
| [M] | [V] | Noise on [M] | Qwen3-VL | MedGemma | ||
| Acc. | Acc. | |||||
| CE | NC | 0% | +1.39 | +22.36 | +1.82 | +34.76 |
| NC | CE | 0% | +5.46 | +37.55 | +3.69 | +57.75 |
| NC | CE | 25% | +4.66 | +34.60 | +3.64 | +54.55 |
| NC | CE | 50% | +3.81 | +32.07 | +3.44 | +49.20 |
| Model / Method | Param. | Liver Cancer | Brain Cancer | Breast Cancer | Average | ||||
| Internal | External | Internal | External | Internal | External | Internal | External | ||
| General Off-the-Shelf MLLMs | |||||||||
| GPT-5.6 Luna [ 38 ] | – | 50.72 | 44.90 | 46.98 | 47.06 | 47.52 | 47.04 | 48.41 | 46.33 |
| Gemini 3.5 Flash [ 16 ] | – | 54.26 | 51.82 | 68.24 | 67.14 | 64.01 | 57.65 | 62.17 | 58.87 |
| DeepSeek-V4.1-Flash [ 9 ] | 552B | 44.54 | 53.58 | 55.25 | 55.41 | 53.05 | 49.63 | 50.95 | 52.87 |
| Qwen3.8-Flash [ 42 ] | – | 49.43 | 51.23 | 53.38 | 53.64 | 48.27 | 47.38 | 50.36 | 50.75 |
| Method | InternVL3-2B [ 58 ] | MedGemma-4B [ 46 ] | ||
| Internal | External | Internal | External | |
| Zero-shot | 42.65 | 34.82 | 43.86 | 37.16 |
| SFT | 65.26 | 52.17 | 70.61 | 54.51 |
| + OPSD | 64.81 | 53.22 | 66.84 | 52.40 |
| + VIVID | 66.54 | 54.04 | 70.76 | 59.91 |
| Method | VQA-RAD | SLAKE | PMC-VQA | ChartQA | Average |
| Qwen3-VL-2B | |||||
| SFT | 62.50 | 68.75 | 47.10 | 76.88 | 63.81 |
| + OPSD | 62.87 | 68.27 | 46.75 | 76.96 | 63.71 |
| + VIVID | 63.24 | 68.99 | 47.50 | 78.56 | 64.57 |
| Qwen3-VL-4B | |||||
| SFT | 63.97 | 74.04 | 51.25 | 81.92 | 67.80 |
| Variant | Qwen3-VL-2B | Qwen3-VL-4B | ||
| Internal | External | Internal | External | |
| Random Reg. | 65.71 | 49.82 | 71.14 | 56.51 |
| Alt. Attn. | 64.73 | 51.47 | 71.06 | 54.28 |
| w/o Proj. | 66.24 | 51.70 | 70.99 | 57.33 |
| VIVID | 66.47 | 52.64 | 71.29 | 57.91 |
| Metric | Qwen3-VL-2B | Qwen3-VL-4B | ||||
| SFT | OPSD | VIVID | SFT | OPSD | VIVID | |
| MS(pp) | 4.92 | 4.99 | 6.64 | 1.21 | 1.22 | 2.45 |
| NLL | 1.53 | 1.64 | 1.34 | 0.87 | 0.91 | 0.85 |
| 6.45 | 6.23 | 8.21 | 13.89 | 12.09 | 14.75 | |
Appendix figures & tables29 assets
Supplementary material from the paper’s appendix.
Appendix
| Source cohort | Train | Int. Test | Ext. Test | Total |
| Liver CT | ||||
| MCT-LTDiag | 450 | 50 | 0 | 500 |
| TriALS | 0 | 0 | 44 | 44 |
| Brain MRI | ||||
| UPENN-GBM | 361 | 42 | 0 | 403 |
| UCSF-PDGM | 242 | 21 | 0 | 263 |
| Score | Assessment criteria |
| 5 | All spatial references are correct and clearly identify the location or region relevant to the question. |
| 4 | Spatial references are correct and unambiguous, with only minor wording imprecision that does not affect localization. |
| 3 | The intended location remains identifiable, but localized errors, omissions, or ambiguous references require substantive clarification. |
| 2 | A major error in anatomical location, laterality, region identity, or inside/outside assignment prevents reliable localization, although some spatial details remain correct. |
| 1 | Spatial references predominantly identify the wrong site or region, contradict the annotations, or fail to establish an interpretable location. |
| Score | Assessment criteria |
| 5 | All claims are medically accurate, supported by the supplied information, and relevant to the question. The evidence clearly supports the reference answer without unsupported findings or unjustified certainty. |
| 4 | The evidence accurately supports the reference answer, with only minor wording imprecision or redundancy and no substantive factual errors. |
| 3 | Non-critical factual errors, omissions, or insufficient explanation weaken answer support, but the core finding remains correct. |
| 2 | Major errors or unsupported inferences concerning lesion presence, multiplicity, composition, or appearance undermine answer support, although some valid information remains. |
| 1 | The central description contradicts the supplied facts or reference answer, reverses the key finding, or consists predominantly of unsupported claims. |
| Dataset | Train | Int. test | Ext. test | Total |
| Liver | 450 / 11778 | 50 / 1327 | 44 / 853 | 544 / 13958 |
| Brain | 976 / 29282 | 108 / 3265 | 167 / 4981 | 1251 / 37528 |
| Breast | 1292 / 28840 | 144 / 3201 | 64 / 1471 | 1500 / 33512 |
| Total | 2718 / 69900 | 302 / 7793 | 275 / 7305 | 3295 / 84998 |
| Dataset | Swap | Acc. | |||
| CE NC | NC CE | CE NC | NC CE | ||
| Liver CT | [M] | -0.55 | +1.92 | -26.47 | +19.12 |
| [V] | -4.51 | +5.58 | -42.65 | +36.76 | |
| -3.96 | +3.66 | -16.18 | +17.65 | ||
| Brain MRI | [M] | -1.00 | +0.96 | -13.96 | +20.05 |
| [V] | -2.69 | +4.36 | -19.29 | +25.38 | |
| Dataset | [M] | [V] | Noise on [M] | Acc. | |
| Liver CT | CE | NC | 0% | -0.55 | -26.47 |
| NC | CE | 0% | -4.51 | -42.65 | |
| NC | CE | 25% | -3.23 | -35.29 | |
| NC | CE | 50% | -1.97 | -23.53 | |
| Brain MRI | CE | NC | 0% | -1.00 | -13.96 |
| NC | CE | 0% | -2.69 | -19.29 |
| Model | Swap | Acc. | |||
| CE NC | NC CE | CE NC | NC CE | ||
| Qwen3-VL | [M] | +3.85 | -1.51 | +15.78 | -6.92 |
| [V] | +8.42 | -3.05 | +26.57 | -10.79 | |
| +4.57 | -1.54 | +10.79 | -3.86 | ||
| MedGemma | [M] | +7.18 | -3.35 | +22.26 | -11.50 |
| [V] | +12.06 | -6.18 | +46.17 | -22.45 | |
| [M] | [V] | Noise on [M] | Qwen3-VL | MedGemma | ||
| Acc. | Acc. | |||||
| CE | NC | 0% | +3.85 | +15.78 | +7.18 | +22.26 |
| NC | CE | 0% | +8.42 | +26.57 | +12.06 | +46.17 |
| NC | CE | 25% | +7.84 | +24.80 | +12.38 | +45.26 |
| NC | CE | 50% | +7.46 | +24.64 | +12.68 | +43.25 |
| Model | Swap | Acc. | |||
| CE NC | NC CE | CE NC | NC CE | ||
| Qwen3-VL | [M] | +3.31 | -2.89 | +14.68 | -13.21 |
| [V] | +7.57 | -6.81 | +41.65 | -24.95 | |
| +4.27 | -3.92 | +26.97 | -11.74 | ||
| MedGemma | [M] | +6.22 | -3.74 | +21.22 | -9.23 |
| [V] | +8.99 | -7.23 | +54.61 | -32.47 | |
| [M] | [V] | Noise on [M] | Qwen3-VL | MedGemma | ||
| Acc. | Acc. | |||||
| CE | NC | 0% | +3.31 | +14.68 | +6.22 | +21.22 |
| NC | CE | 0% | +7.57 | +41.65 | +8.99 | +54.61 |
| NC | CE | 25% | +7.58 | +36.15 | +8.95 | +51.29 |
| NC | CE | 50% | +7.41 | +32.84 | +8.99 | +44.28 |
| Model | Swap | Acc. | |||
| CE NC | NC CE | CE NC | NC CE | ||
| Qwen3-VL | [M] | +1.07 | -1.25 | +21.21 | -10.77 |
| [V] | +4.53 | -3.30 | +33.00 | -19.87 | |
| +3.45 | -2.05 | +11.78 | -9.09 | ||
| Metric | CE [M] | CE [V] | ||
| No noise | No noise | 25% noise | 50% noise | |
| +1.07 | +4.53 | +4.13 | +3.72 | |
| Acc. | +21.21 | +33.00 | +30.98 | +28.28 |
| Configuration | SFT | On-policy Distillation |
| Image Input | ||
| Image size | ||
| LoRA | ||
| Rank / alpha | 64 / 128 | 64 / 128 |
| Dropout | 0.05 | 0.05 |
| Target modules | Decoder linear | Decoder linear |
| Test set | OPSD | Med-OPD | VA-OPD | VIVID |
| Internal | 62.59 1.59 | 64.56 0.28 | 62.80 0.46 | 66.54 0.35 |
| External | 46.62 1.06 | 47.13 0.59 | 46.23 0.48 | 52.17 0.47 |
| Method | Qwen3-VL-2B | Qwen3-VL-4B | ||
| Internal | External | Internal | External | |
| Lesion Identification (2 options) | ||||
| OPSD | 72.30 | 54.32 | 77.50 | 64.61 |
| Med-OPD | 72.04 | 52.47 | 78.67 | 62.96 |
| VA-OPD | 71.26 | 52.88 | 78.80 | 64.20 |
| VIVID | 74.90 | 61.93 | 79.06 | 66.87 |
| Scale | Method | Training | Inference | ||
| s/step | GiB | s/question | GiB | ||
| 2B | Med-OPD | 86.10 | 19.88 | 1.44 | 4.07 |
| VA-OPD | 73.49 | 16.35 | 1.53 | 4.07 | |
| VIVID | 47.46 | 30.31 | 1.53 | 4.07 | |
| 4B | Med-OPD | 85.38 | 44.94 | 1.71 | 8.44 |
| VA-OPD | 91.94 | 35.30 | 1.86 | 8.44 | |
| Variant | Qwen3-VL-2B | Qwen3-VL-4B | ||
| Internal | External | Internal | External | |
| Attention Coverage | ||||
| 65.56 | 50.88 | 70.99 | 56.39 | |
| 66.16 | 51.82 | 70.91 | 57.44 | |
| Value Mixing Ratio | ||||
| 66.31 | 52.52 | 71.14 | 56.62 | |
| Dataset | Early | Middle | Late | Overall |
| Qwen3-VL-2B | ||||
| Liver CT | 14.68 | 9.68 | 9.10 | 11.08 |
| Brain MRI | 18.37 | 14.92 | 15.07 | 16.08 |
| Breast MRI | 10.84 | 10.04 | 8.58 | 9.78 |
| Qwen3-VL-4B | ||||
| Liver CT | 14.82 | 8.49 | 6.63 | 9.98 |
| Dataset | Cosine | Positive (%) | Retained (%) |
| Qwen3-VL-2B | |||
| Liver CT | 0.224 | 83.61 | 24.54 |
| Brain MRI | 0.208 | 82.13 | 23.53 |
| Breast MRI | 0.247 | 85.02 | 26.81 |
| Qwen3-VL-4B | |||
| Liver CT | 0.197 | 80.43 | 22.23 |
| Score | Assessment criteria |
| 5 | Core facts agree with the reference, with no substantive contradictions. Paraphrases and omissions that do not affect the factual meaning are acceptable. |
| 4 | Core facts agree, but minor details are omitted, descriptions are less precise, or additional details cannot be verified from the reference. |
| 3 | The evidence partially agrees with the reference but omits key information, is too vague to establish the main finding, or introduces substantial unsupported details. |
| 2 | The evidence substantively contradicts the reference regarding lesion presence, multiplicity, composition, location, candidate regions, or important imaging characteristics. |
| 1 | The core facts are predominantly opposite to the reference, the content is irrelevant, or no usable evidence is provided. |
| Score | Assessment criteria |
| 5 | The evidence clearly and sufficiently supports the predicted answer, with no internal contradictions. |
| 4 | The evidence generally supports the predicted answer, but contains a minor reasoning gap or an imprecise statement of scope. |
| 3 | The evidence is compatible with the predicted answer but is too vague or incomplete to distinguish it from alternative options. |
| 2 | The evidence mainly supports another answer or contains a substantial contradiction, although some support for the predicted answer remains. |
| 1 | The evidence directly contradicts the predicted answer, or no usable evidence is provided. |
| Dataset | SFT | OPSD | Med-OPD | VA-OPD | VIVID |
| Liver | 4.01±1.10 | 4.03±1.10 | 4.06±1.00 | 4.05±1.02 | 4.17±0.89 |
| Brain | 4.72±0.64 | 4.65±0.61 | 4.68±0.60 | 4.68±0.60 | 4.74±0.58 |
| Breast | 4.16±0.93 | 4.14±0.94 | 4.14±0.90 | 4.10±0.95 | 4.18±0.94 |
Medical VLMs
Medical vision-language models connect clinical images with text for diagnosis, reporting, question answering, and image grounding.
See all 535 papers