Recovering globally consistent 3D human motion from monocular videos remains challenging under dynamic camera motion. Although SLAM and human mesh recovery (HMR) provide complementary camera and body estimates, directly combining them often leads to inconsistent orientations and accumulated trajectory drift. We present GravHMR, a training-free, plug-and-play framework that couples SLAM and HMR through a shared gravity-aligned reference. By allowing gravity to be estimated independently of the HMR backbone, GravHMR accommodates world-grounded HMR models with or without explicit gravity-view representations. Specifically, Yaw-Aware Orientation Optimization (YAOO) resolves heading inconsistencies by correcting body and velocity orientations about the shared gravity axis. Conditioned on these corrected orientations, Gravity-Aware Trajectory Optimization (GATO) anchors root trajectories in the metric SLAM world by jointly leveraging 2D reprojection, the metric scale implicit in the human body, and the body's own motion. On EMDB-2, GravHMR achieves state-of-the-art performance with 154.0 mm W-MPJPE100 using ViPE and 189.8 mm using masked DROID-SLAM, outperforming TRAM (222.4 mm) under the same masked DROID-SLAM camera estimates. It further reduces W-MPJPE100 by 44.3% over GVHMR (276.5 mm) and by 20.0% over GVHMR + HTD-Refine (192.4 mm) with the same HMR backbone.
Figures & tables
Figure 1: Motivating observation: orientation inconsistency in world-grounded human reconstruction. Directly lifting camera-space body estimates into the world using independently estimated SLAM camera poses can propagate orientation errors, as illustrated by TRAM ( red ). In contrast, GravHMR reconciles body and camera orientations through a shared gravity reference, yielding an upright reconstruction more consistent with the ground truth ( gray ).
Figure 2: Overview of GravHMR. Given a monocular video, off-the-shelf HMR and SLAM backbones provide initial human motion and camera geometry, respectively. GravHMR couples these estimates through a shared gravity-aligned reference. Yaw-Aware Orientation Optimization (YAOO) corrects the headings of the body and of its motion about gravity while keeping the gravity-relative body tilt predicted by HMR. Gravity-Aware Trajectory Optimization (GATO) then recovers the global root trajectory from 2D pose observations under the corrected orientations and the SLAM camera geometry, and Flow-Aware Temporal Consistency (FATC) finally regularizes its temporal derivatives.
Method
EMDB-2
RICH
WA-MPJPE 100↓
W-MPJPE 100↓
RTE ↓
Jitter ↓
FS ↓
WA-MPJPE 100↓
W-MPJPE 100↓
RTE ↓
Jitter ↓
FS ↓
SLAHMR [ 33 ]
326.9
776.1
10.2
–
–
98.1
186.4
28.9
34.3
5.1
WHAM [ 23 ]
135.6
354.8
6.0
22.5
4.4
109.9
184.6
4.1
19.7
3.3
TRAM [ 29 ]
76.4
222.4
1.4
18.5
23.4
103.6
168.4
2.7
18.7
12.9
GVHMR [ 22 ]
111.0
276.5
2.0
16.7
3.5
78.8
126.3
2.4
12.8
3.0
GVHMR + PVA-Net [ 22 , 31 ]
106.7
262.8
2.1
15.2
3.4
74.0
119.1
2.3
10.7
2.7
Table 1: Global human motion on EMDB-2 and RICH. WA-/W-MPJPE 100 and FS in mm, RTE in %, Jitter in 10m/s3 . Ours w/ ViPE uses ViPE camera poses and estimated intrinsics; Ours w/ masked DROID-SLAM uses the camera poses of TRAM and ground-truth intrinsics, as TRAM does. Best in bold , second underlined .
Figure 3: Qualitative comparison of global human motion. GT ( ), GravHMR ( ), and TRAM ( ) on three EMDB-2 sequences. GravHMR uses ViPE cameras; TRAM uses its masked DROID-SLAM cameras with ground-truth intrinsics. Each rendered 15 s window is aligned to the ground truth on its first 60 frames. Insets: top-down root paths of the whole sequence.
Figure 4: Gravity-aligned coupling improves body pose and root orientation. Qualitative comparison on EMDB-2 sequence P7_61 . TRAM (top, red) and ours (bottom, blue) are overlaid on the ground truth (gray), translated to the ground-truth pelvis without rotational alignment.
Method
WA 100↓
W 100↓
ERVE ↓
Jitter
FS ↓
Reference configurations
GVHMR rollout
106.7
262.8
11.6
15.2
3.4
YAOO ablations
w/o YAOO body
62.7
176.9
10.8
35.0
6.3
w/o YAOO body & motion
64.1
191.5
11.1
36.1
6.5
GATO ablations
Table 2: Ablation of the core reconstruction on EMDB-2. All variants use the same ViPE camera poses and intrinsics and are evaluated before FATC. “w/o YAOO body” keeps the rollout body orientation but the yaw-corrected motion prior; “w/o YAOO body & motion” reverts both to the rollout. Each GATO ablation drops one loss term and re-optimizes. The last row adds FATC to the full core and is not ranked. Best variant in bold, except for Jitter (lower may indicate over-smoothing).
Method
Global motion
Orientation (deg)
WA 100↓
W 100↓
RTE ↓
Etilt
Eyaw↓
Edir↓
EMDB-2
w/o GravHMR
106.7
262.8
2.10
8.14
7.33
11.8
w/ GravHMR
57.6
155.3
1.27
8.18
6.69
5.4
EgoBody
w/o GravHMR
129.4
203.5
3.85
5.73
7.04
30.2
Table 3: System-level ablation of GravHMR. Each pair uses identical backbone predictions and ViPE camera parameters, evaluated before FATC. Etilt , Eyaw , and Edir measure body tilt, heading, and travel-direction errors in degrees.
Figure 5: GravHMR corrects global motion beyond locally plausible poses. We compare reconstructions without (orange) and with (blue) GravHMR on two EMDB-2 sequences. Gray meshes and dashed curves indicate ground-truth bodies and root trajectories, respectively.
Body orientation Rt
W 100↓
Orientation (deg)
Etilt↓
Eyaw↓
Edir↓
Rollout (w/o YAOO)
191.5
8.34
7.31
5.4
Full camera orientation
165.7
8.34
6.76
5.4
Yaw only (YAOO, ours)
155.3
8.18
6.69
5.4
Table 4: How much of the camera-derived orientation to adopt. Rollout keeps Rtroll for the body and the motion prior; yaw only is YAOO (Eq. ( 4 )); full uses Rt of Eq. ( 2 ) as the body orientation. All rows share the ViPE camera, the HMR prediction and GATO, and are evaluated before FATC on EMDB-2. Edir is identical across the three rows.
Depth source
EMDB-2
EgoBody
WA 100↓
W 100↓
WA 100↓
W 100↓
w/o GravHMR
106.7
262.8
129.4
203.5
2D body extent
57.7
155.3
133.0
205.0
HMR depth
57.6
155.3
87.5
123.3
Table 5: Source of the root depth along the viewing ray (Eq. ( 5 ) and Eq. ( 8 )), on EMDB-2 and EgoBody with ViPE cameras, before FATC. 2D body extent takes the depth of the per-frame 2D root solve; HMR depth takes ztHMR . The first row is the GVHMR rollout and uses neither.
Appendix figures & tables11 assets
Supplementary material from the paper’s appendix.
Appendix
Method
PA-MPJPE ↓
MPJPE ↓
PVE ↓
Accel ↓
Per-frame methods
SPIN [ 14 ]
69.7
122.9
144.2
35.2
CLIFF [ 17 ]
56.6
102.6
115.0
22.4
HMR2.0 [ 5 ]
48.1
96.0
110.9
18.8
ReFit [ 28 ]
47.9
80.7
92.9
17.1
Temporal methods
Appendix
Table A1 : Camera-space reconstruction on the RICH test set. PA-MPJPE, MPJPE, and PVE are in mm, and Accel is in m/s 2 . Baseline results are taken from GVHMR [ 22 ] , while ours is evaluated on 191 views following the GVHMR metric protocol. Differences in inference settings may remain. Best in bold , second best underlined .
Part from GravHMR
Global motion
Root trajectory
Heading
Speed & vertical
W-MPJPE 100↓
WA-MPJPE 100↓
RTE ↓
ERVE ↓
W-RVE ↓
EMDB-2
✗
✗
262.8
106.7
2.10
11.6
8.13
✓
✗
247.4
97.8
1.88
11.2
7.28
✗
✓
245.3
91.0
2.09
12.1
8.03
✓
✓
155.3
57.6
1.27
10.2
5.81
Appendix
Table A2 : Component swap between the GVHMR rollout and GravHMR. ✓ takes the part from the full core (before FATC), ✗ from the GVHMR rollout; the trajectory is re-integrated without re-optimization. Heading is the body and travel yaw (YAOO); speed & vertical is the horizontal speed and vertical motion of the root (GATO). Body pose remains unchanged. W-RVE is evaluated after a single yaw alignment over the first 2 s. Best results are marked in bold.
Method
Poses
K
∣Δf∣ (%)
PA-MPJPE
WA 100
W 100
RTE
ERVE
Jitter
FS
TRAM
masked DROID
TRAM est.
7.7
37.9
104.9
304.9
2.97
20.2
106.1
19.5
TRAM
masked DROID
GT
–
37.7
80.1
222.2
1.42
18.9
104.6
18.2
Ours
ViPE
ViPE est.
0.6
29.5
57.4
154.0
1.29
9.2
8.4
5.2
Ours
ViPE
GT
–
29.5
57.4
154.1
1.29
9.2
8.4
5.2
Ours
masked DROID
TRAM est.
7.7
29.7
92.3
270.4
2.99
10.7
6.5
7.1
Ours
masked DROID
GT
–
29.5
66.6
189.8
1.43
9.2
6.7
5.4
Appendix
Table A3 : Effect of the camera intrinsics on EMDB-2 (25 sequences, frame-weighted). ∣Δf∣ is the mean absolute focal-length error relative to ground truth. TRAM uses the named intrinsics for both masked DROID-SLAM and its human regressor, so its camera poses differ between the two rows. Ours (ViPE, GT K) keeps the ViPE poses and uses ground-truth intrinsics in the HMR input, GATO, and FATC. The last two rows use masked DROID-SLAM, as Ours w/ masked DROID-SLAM in Tab. 1 . WA 100 , W 100 , PA-MPJPE, and FS are in mm, RTE in %, Jitter in 10m/s3 . All rows are computed with one evaluator, so TRAM can differ from the values reported in Tab. 1 .
Figure A1 : Per-joint reprojection reliability result. MAD σk of each joint’s reprojection residual (median over sequences, log scale). Reliability degrades from proximal to distal joints on both datasets, and the degradation is amplified under truncation (EgoBody), most severely along the lower limb (ankle: 16 px → 219 px). This scene-dependent pattern motivates per-frame, per-joint weights rather than a fixed anchor set.
Gravity source
WA 100
W 100
ERVE
Jitter
FS
HMR rollout (main results)
57.6
155.3
10.2
32.1
7.8
GeoCalib
62.8
155.3
10.7
36.6
8.0
Ground truth
63.5
160.0
10.8
35.8
6.7
Appendix
Table A4 : Gravity source on EMDB-2. The body orientation Rt is rotated minimally so that its vertical matches the named source; in the main configuration it is the vertical of the HMR rollout (Eq. ( 4 )). In all rows the world frame is set by GeoCalib (Eq. ( 1 )), the cameras are from ViPE, and results are before FATC. Units follow Tab. 1 .
Stage
Seconds
FPS
ViPE (full)
3233
1.9
GeoCalib (1 in 5 frames)
267
23.1
HMR2 features
253
24.4
GVHMR forward
5
1190
PVA-Net crops (CPU)
357
17.3
PVA-Net inference
323
19.1
Appendix
Table A5 : Runtime per stage on three EMDB-2 sequences (6170 frames in total). HMR, PVA-Net, GATO, and FATC were measured on a Tesla V100. HMR2 and GVHMR times exclude model loading and image decoding; the FATC time includes start-up and post-processing. GATO and the FATC optimization use a fixed iteration count, so they take about 10 s and 80 s per sequence regardless of length. ViPE and GeoCalib times come from earlier run logs; ViPE ran at 384×512 on most sequences.
W-MPJPE ↓
WA-MPJPE ↓
RTE(%) ↓
TRAM-style translocation
2651.1
955.0
8.8
Ours w/o optimization
415.3
94.8
1.4
Ours
405.4
93.9
1.1
Appendix
Table A6 : World-frame trajectory recovery on WorldPose. TRAM-style translocation fails under broadcast camera zoom, while ours remains robust.
Structural
Dynamic
EMDB-2
EgoBody
WA-MPJPE ↓
W-MPJPE ↓
WA-MPJPE ↓
W-MPJPE ↓
58.5
156.7
149.1
232.3
✓
58.0
156.0
122.9
181.9
✓
57.7
155.5
102.1
144.9
✓
✓
58.0
155.6
97.2
136.1
Detector Confidence
57.7
155.3
133.0
205.0
Appendix
Table A7 : Ablation of per-joint weighting strategies. Comparison of structural and dynamic weighting in GATO on EMDB-2 and EgoBody, with the depth of the per-frame 2D root solve ( 2D body extent in Tab. 5 ). Both strategies improve robustness under challenging body observations.
Figure A2 : Global human motion placed in the scene. Ground truth ( gray ), TRAM ( red ) and GravHMR (ours, blue ) at several time steps, beside sampled input frames with ground-truth overlays. The scenes in (b) and (c) are ViPE’s own reconstruction, carried over unchanged: GravHMR never reads them, and nothing here is optimized against them. We show them because the bodies land in the scene the camera reconstructed without being asked to, which is what a future joint optimization of body and scene would start from. Panel (a) carries no scene and shows the bodies alone.
Figure A3 : Global trajectories of the HMR backbone with and without GravHMR. Top-down root paths along the gravity axis on four EMDB-2 sequences, each shown with one input frame. Ground truth (gray band), the GVHMR rollout without GravHMR (orange), and GravHMR (blue). Each prediction is aligned to the ground truth by one Sim(3) fitted on the first 100 frames, and the whole sequence is drawn. Dashed segments connect the rollout and the ground truth at the same instant. Numbers at the top right are the mean horizontal root error over the sequence.
Figure A4 : In-the-wild videos, with and without GravHMR. Six clips for which no ground truth exists. Each cell shows four input frames, then the GVHMR + PVA-Net rollout ( orange , top) and GravHMR ( blue , bottom) over the same window, at eight time steps each; the circle marks the start the two share. One camera is fitted to both reconstructions and used for both panes , so the difference in travelled distance is measured rather than produced by the viewpoint. A pane cannot hold a long trajectory and still show a body, so each clip is drawn from its start until GravHMR has travelled 14 m, or for a third of the clip, whichever is longer; the header gives the window and the full clip length, and the distances are measured inside the window. Cameras are from ViPE and the world is set upright with GeoCalib gravity; the rollout is already expressed in a gravity-aligned frame and is left untouched.