cs.CVNov 23, 2026

Advancements in Diabetic Retinopathy Classification Using Novel Multi-Stacked U-Net Architectures

Authors: Ameya Uppina, S Navaneetha Krishnan, Talluri Krishna Sai Teja, Joe Dhanith P R

Organizations: School of Computer Science and Engineering, Vellore Institute of Technology Chennai Campus, India

Abstract

Diabetes leads to several health complications throughout the body, with the complication in the eyes being Diabetic Retinopathy. It leads to damaging or abnormal changes in the blood vessels' structure, causing vision loss. The need for massive screening of a large population of diabetic patients has created a necessity for computer-aided, fully automatic diagnosis of DR. CNNs have shown great promise in the classification of DR based on the Fundus images. Building a reliable model faces considerable challenges due to the limited availability of high-quality annotated datasets and issues with varying image quality and class imbalances. This paper aims to demonstrate the UNET, and its Stacked Architecture variant and their performance across several datasets. This paper has compared and studied the UNET architecture's performance across multiple stacks and has come to a soft conclusion that the architecture performs its best at three stacks, and any more leads to deterioration of its performance. The model aims at classifying the images into five categories, 0 to 4, where 0 is no DR, and 4 is proliferative DR.

Explore similar work

Nov 2, 2024

Enhancing Diabetic Retinopathy Detection with CNN-Based Models: A Comparative Study of UNET and Stacked UNET Architectures

Diabetic Retinopathy DR is a severe complication of diabetes. Damaged or abnormal blood vessels can cause loss of vision. The need for massive screening of a large population of diabetic patients has generated an interest in a computer-aided fully automatic diagnosis of DR. In the realm of Deep learning frameworks, particularly convolutional neural networks CNNs, have shown great interest and promise in detecting DR by analyzing retinal images. However, several challenges have been faced in the application of deep learning in this domain. High-quality, annotated datasets are scarce, and the variations in image quality and class imbalances pose significant hurdles in developing a dependable model. In this paper, we demonstrate the proficiency of two Convolutional Neural Networks CNNs based models, UNET and Stacked UNET utilizing the APTOS Asia Pacific Tele-Ophthalmology Society Dataset. This system achieves an accuracy of 92.81% for the UNET and 93.32% for the stacked UNET architecture. The architecture classifies the images into five categories ranging from 0 to 4, where 0 is no DR and 4 is proliferative DR.
Oct 13, 2026

HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.
May 12, 2026

Diabetic Retinopathy Classification using Downscaling Algorithms and Deep Learning

Diabetic Retinopathy (DR) is an art and science of recording and classifying the retinal images of a diabetic patient. DR classification deals with classifying retinal fundus image into five stages on the basis of severity of diabetes. One of the major issue faced while dealing with DR classification problem is the large and varying size of images. In this paper we propose and explore the use of several downscaling algorithms before feeding the image data to a Deep Learning Network for classification. For improving training and testing; we amalgamate two datasets: Kaggle and Indian Diabetic Retinopathy Image Dataset. Our experiments have been performed on a novel Multi Channel Inception V3 architecture with a unique self crafted preprocessing phase. We report results of proposed approach using accuracy, specificity and sensitivity, which outperform the previous state of the art methods. Index Terms: Diabetic Retinopathy, Downscaling Algorithms, Multichannel CNN Architecture, Deep Learning