cs.RONov 23, 2026

SurgeCount: A Protocol-Guided Composition Harness for Bimanual Surgical Sponge Counting

Authors: Sung Eun Kim, Xiaoman Zhang, Xucheng Wang, Pranav Rajpurkar

Organizations: Department of Biomedical Informatics, Harvard Medical School, Boston, MA, USA

Abstract

We present SurgeCount, a system for auditable robotic surgical sponge counting that composes learned skills under a written procedural protocol. Retained sponges cause preventable harm, and surgical teams count every sponge before closure to reduce that risk. The robot repeatedly isolates one deformable sponge from a tangled pile and places it in the next numbered counting-tray slot, requiring handling of occluded grasp threads while preserving step order. We train one subtask-conditioned policy on eleven short skills and learn when each skill ends. At each learned boundary, a stateful vision-language model selects the next skill from an operator-authored specification of step order, visual verification, and recovery. This creates temporal commitment to each subtask and enables failures to be recovered by recomposing existing skills rather than using a dedicated recovery policy. We evaluate five methods across 100 real-robot trials using 20 matched layouts. SurgeCount fills 47 of 60 ordered slots and completes 12 of 20 procedures, compared with 27 of 60 and 3 of 20 for the strongest of four end-to-end policies trained on the same data. Replacing the detailed protocol prompt with a minimal prompt reduces performance to 29 of 60 slots and 5 of 20 completed procedures. These results show that long-horizon performance depends not only on visuomotor capacity, but also on how learned skills are committed, verified, and composed. This tabletop proof of concept motivates further evaluation of protocol-guided robotic sponge counting in clinically representative settings.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Oct 18, 2026

SurGPT: A Multi-Task Foundation Model for Robotic Surgical Skills Assessment and Gesture Recognition

The assessment of surgical skills in robotic surgery training has traditionally relied on subjective evaluations by human experts, creating bottlenecks in surgical education and limiting scalability. We present a novel foundation model that automatically analyzes robotic surgical videos to provide comprehensive skill assessment and gesture understanding. Combining a visual encoder with a transformer architecture, the model performs three key tasks simultaneously: 1) surgical task classification (knot tying, needle passing, suturing), 2) skill level assessment on a standardized scale, and 3) natural language generation of surgical gesture descriptions. The model processes video sequences from the da Vinci surgical robot and generates human-readable text descriptions of surgical actions, similar to how language models generate text from prompts, using a multi-task learning framework with adaptive uncertainty weighting to optimize performance across all objectives. Our transformer-based architecture incorporates positional encoding for temporal understanding and attention mechanisms for spatiotemporal feature integration. Evaluated on the da Vinci Skills Simulator dataset, the proposed framework demonstrates state-of-the-art performance in surgical task recognition and provides interpretable skill assessments that correlate with expert evaluations, with the model's ability to generate natural language descriptions of surgical gestures opening new possibilities for automated surgical education, real-time feedback systems, and objective skill assessment in surgical training and certification programs.
Oct 11, 2026

SurgiCLAW: An Interpretable Atomic-Skill Agent for Precision Robotic Micromanipulation

Recent multimodal large language models (MLLMs) and vision--language--action models have provided robots with new capabilities for long-horizon task understanding and planning. In surgical robotics, however, end-to-end prediction of low-level actions remains limited by insufficient precision, opaque decisions, and scarce data. This paper presents SurgiCLAW, a hierarchical skill-based framework for precision surgical manipulation. SurgiCLAW confines an MLLM to intraoperative visual understanding, structured explanation, and atomic surgical-skill selection, while delegating physical execution to verifiable deterministic control programs. For brain--machine-interface implantation, a representative high-precision surgical task, we construct a state-to-skill invocation dataset and expand it through visual and state perturbations. The model first learns structured skill invocation through supervised fine-tuning and is then optimized using three rewards for action correctness, operation prerequisites, and format validity, improving action selection, operational safety, and output parseability. We evaluate subtask success, offline model comparison, real-robot performance, and ablations. On a fixed test set, SurgiCLAW achieves 94.6% skill-selection accuracy and 93.0% macro-averaged F1 (Macro-F1). Across 50 closed-loop real-robot implantation trials, it achieves an 88.0% task success rate.
Nov 22, 2026

Phase-Conditioned Action Contracts for Auditable Microsurgical Control

Staged robotic procedures may reuse a fixed-dimensional policy output even though the admissible motions and physical meanings of its coordinates change across phases. We call this action-semantic shift. To address it, we propose a phase-conditioned executable policy that separates learned action proposal from deterministic command formation. Phase-specific heads generate proposals, while an action contract removes inadmissible components, enforces state-dependent bounds, and decodes the remaining action into phase-dependent task-space commands. We further introduce failure-focused local repair and a read-only provenance trace for exact command replay and rule-level auditing. Across three held-out retinal-injection evaluation blocks, our method achieves 94.27±0.64%94.27\pm0.64\% procedural completion and 64.40±2.43%64.40\pm2.43\% success within 35 μm35\,μ\mathrm{m}, with no hard violations. Applying the contract and decoder to the same frozen Correction network raises completion from 12.27%12.27\% to 90.47%90.47\%. The trace exactly reconstructs 96,350 commands, and all 1,996 binding interventions follow their declared effects. These results show the importance of explicit executable action semantics for auditable staged microsurgical control.