Completing analytical conversion scheme among DH, Hayati, CPC and POE models for manipulator calibration
Authors: Oleg Yu. Sumenkov, Danil D. Kulminskiy, Sergei V. Gusev
Organizations: Mathematical Robotics Science Division, Sirius University of Science and Technology, Olimpiyskiy Ave 1, Sirius, 354340, Sirius Federal Territory, Russia
Building on Mooring's decomposition of the calibration procedure into four stages - modeling, measurement, identification, and correction - this paper investigates the role of analytical kinematic model conversion algorithms within the calibration framework and their potential to improve calibration performance. Four prominent and widely cited kinematic models: Denavit-Hartenberg (DH), Hayati (HAY), Complete and Parametrically Continuous (CPC), and Product of Exponentials (POE), - are considered. A systematic analysis of the existing conversion relationships reveals that, although most conversions among these models have already been established in the literature, a direct analytical conversion between POE and HAY, and CPC and HAY remains unavailable. Relying instead on a sequential combination of the existing POE-DH and DH-HAY conversions, for example, introduces several limitations. To address this gap, we develop a constructive analytical conversion between POE-HAY and HAY-CPC models based on Lie group theory, formally established through a set of lemmas and propositions. The proposed algorithms are illustrated using an RRRP SCARA robot and an RRHHHH Puma 560 manipulator. The direct POE-HAY conversion is compared with the sequential POE-DH-HAY approach, as well as HAY-CPC in terms of several relevant criteria, demonstrating the advantages of the proposed solution. Finally, we demonstrate the practical significance of the completed analytical conversion framework in an open-loop kinematic calibration experiment on an ABB IRB 1600 manipulator, using an API Radian EMSD3 Laser Tracker for measurements. The experimental results demonstrate that proper model selection combined with completed analytical conversion scheme directly improves calibration accuracy.
Figures & tables
Models
Papers
Citation count
DH
( Denavit and Hartenberg, 1955 )
≈8000
( Paul, 1981 )
≈7000
mDH
( Khalil and Kleinfinger, 1986 )
≈700
HAY
( Hayati, 1983 )
≈600
( Hayati and Mirmirani, 1985 )
≈550
CPC
( Zhuang et al., 1990 )
≈400
Table 1: Citation distribution among the DH (mDH), HAY, CPC (mCPC) and POE models
Figure 1: Conversions schemes between DH, HAY, CPC, and POE models: existing (left) and proposed (right)
Nominal
Actual
θ , rad
d , mm
α , rad
a , mm
β , rad
θ , rad
d , mm
α , rad
a , mm
β , rad
TWF0
0
0
0
0
—
1.107
1.000
0.0447
0.000
—
T01
0
0
1.5708
0
—
2.0340
−1.0214
−1.5508
0.0092
—
T12
0
0
0
100
0
−3.1022
0
0.0009
102.6865
0.1790
T23
0
−50
1.5708
150
—
0.0638
−24.1168
1.5716
153.3035
—
T34
3.1416
20
1.5708
0
—
−2.9640
30.1922
1.5837
1.8365
—
Table 2: HAY parameters of nominal and actual Puma 560 mode obtained with sequential POE–DH–HAY ( Wu et al., 2017 ; Kuti and Galambos, 2024 ) conversion
Figure 2: The framework for robot calibration using analytical conversion of DH, HAY, CPC, and POE models in Fig. 1 .
Notation
Description
Type
a , b
Scalars
R
q , Φ
Vectors
Sn , Rn
T , H
Matrices
Rn×n
{i} , {j}
Coordinate frame associated with i -th and j -th link, resp.
—
Rotk(γ)
Homogeneous transformation matrix representing rotation about k by γ
SE(3)
Tranl(v)
Homogeneous transformation matrix representing translation along l by v
SE(3)
Table 3: Summary of the mathematical notation used throughout the paper
Figure 3: DH frames for a revolute joints mechanism
Figure 4: Example of a parameter singularity in the DH convention: nominal configuration (left) and configuration with an angular perturbation ϵ (right).
θ , rad
d , mm
α , rad
a , mm
nominal
qi
0
0
l
perturbed
qi−π/2
−d
−ϵ
0
Table 4: Nominal and perturbed DH parameters in a singular configuration.
Figure 5: Example of Hayati model application for the consecutive parallel joints (revolute and prismatic)
Figure 6: CPC modelling convention for a revolute joint
Figure 7: POE model conventions for revolute and prismatic joints.
Figure 8: Schematic of the DH–CPC conversion proposed in ( Zhuang et al., 1992 )
Figure 9: Schematic representation of the SCARA robot
ω
v
ξ1
0
0
1
0
0
0
ξ2
0.0504
-0.0303
0.9983
-0.1326
-99.9484
-3.0220
ξ3
0
0
1
0
-200
0
ξ4
0
0
0
-0.0200
0.0100
0.9998
ξTool
0.1000
-0.0600
-0.0300
201
1
201
Table 5: POE parameters of SCARA manipulator ( Lynch and Park, 2017 )
θ , rad
d , mm
α , rad
a , mm
β , rad
b , mm
TWF0
0
0
0
0
0
—
T01
−0.0013
0
0.0302
100.1217
0.0505
—
T12
0.0011
0
−0.0303
100.0056
−0.0504
—
T23
0
0
−0.0100
0
−0.0200
—
T34T4Tool
−0.0306
213.0745
0.1103
−0.6115
−0.0383
−14.4181
Table 6: Converted HAY parameters of SCARA manipulator
b
l
β
TWF0
0
0
1.0
0
0
0
0
T01
0.0504
−0.0303
0.9983
99.9942
−0.0564
0
0
T12
−0.0504
0.0303
0.9983
100.1331
−0.0200
0
0
T23
−0.0200
0.0100
0.9998
0.0001
0.0000
0
0
T34T4Tool
−0.0415
−0.1088
0.9932
7.4994
9.0282
211.6515
−0.0313
Table 7: Converted CPC parameters of SCARA manipulator
Figure 10: Position epos and orientation eor errors ( 55 ) between the SCARA robot model with POE parameters (Table 5 ) and the converted HAY parameters (Table 6 ) tested on 1000 random configurations.
Figure 11: Position epos and orientation eor errors ( 55 ) between the SCARA robot model with HAY parameters (Table 6 ) and the converted CPC parameters (Table 7 ) tested on 1000 random configurations.
Mean
Max
Std
pos.
or.
pos.
or.
pos.
or.
10−17 m
10−16 rad
10−16 m
10−15 rad
10−17 m
10−16 rad
POE–HAY
6.2025
2.0612
2.0691
1.0766
3.2028
1.6534
HAY–CPC
8.1951
4.2354
1.6631
1.0267
3.2976
1.5736
Table 8: Statistics of the position and orientation errors ( 55 ).
Nominal
Actual
ω
v
ω
v
h
ξ1
0
0
1
0
0
0
0.04
-0.02
0.999
0.02
0.04
0
0
ξ2
0
-1
0
0
0
0
0
-1.000
0
-0.02
0
0.05
0
ξ3
0
-1
0
0
0
-100
0.178
-0.984
-0.001
-0.07
0.009
-101
0.080
ξ4
0
0
-1
-50
250
0
0.062
0.013
-0.998
-51
249
0.075
-4.96e-5
ξ5
0
-1
0
-20
0
-250
0.001
-1.000
0
-20.6
-0.021
-249
8.24e-7
Table 9: Nominal and actual POE parameters of Puma 560 ( Okamura and Park, 1996 )
Figure 12: Schematic representation of the Puma 560 manipulator in POE form
Nominal
Actual
θ , rad
d , mm
α , rad
a , mm
β , rad
b , mm
θ , rad
d , mm
α , rad
a , mm
β , rad
b , mm
TWF0
0
0
0
0
0
—
1.1071
1.0000
0.0447
0
0
—
T01
0
0
1.5708
0
0
—
−1.1075
−1.0214
1.5508
−0.0092
0
—
T12
0
0
0
100
0
—
0.0394
0
0.0009
102.6885
0.1790
—
T23
0
−50
1.5708
150
0
—
0.0638
−24.1168
1.5716
153.3035
0
—
T34
0
20
−1.5708
0
0
—
0.1775
30.1922
−1.5837
−1.8365
0
—
Table 10: HAY parameters of nominal and actual Puma 560 mode obtained with proposed POE–HAY conversion
Conversion errors
Computational time
Mean
Max
Mean
Max
Min
Std
pos.
or.
pos.
or.
10−16 m
10−15 rad
10−16 m
10−15 rad
10−5 sec
10−5 sec
10−5 sec
10−6 sec
POE–DH–HAY
3.8498
1.8779
12.3406
4.0846
13.43
25.06
12.81
9.11
POE–HAY
2.4652
0.5394
9.5718
2.4345
13.09
22.61
12.49
8.35
Table 11: Comparison of sequential POE–DH-HAY ( Wu et al., 2019 ; Kuti and Galambos, 2024 ) and proposed POE–HAY conversion algorithms: Position and orientation errors for the PUMA 560 robot across 10000 configurations and computational time over 10000 runs
b
l
β
TWF0
0.0400
−0.0200
0.9990
0.0000
0.0447
0.9990
1.1071
T01
−0.8944
−0.4468
0.0200
−0.0092
−1.0212
−0.0204
−1.1075
T12
0.1779
0.0061
0.9840
101.0485
0.0000
18.2792
0.0395
T23
0.0638
−0.9980
−0.0008
153.3035
−24.1168
0.0183
0.0638
T34
−0.1766
0.9842
−0.0129
−1.8365
−30.1897
−0.3906
0.1775
T45
0.1566
0.9872
−0.0309
−0.7408
−0.4752
−0.0147
−0.1573
Table 12: CPC parameters of actual Puma 560 model obtained with HAY–CPC ( Zhuang et al., 1992 )
b
l
β
TWF0
0.0400
−0.0200
0.9990
−0.0400
0.0200
0
0
T01
−0.0004
−0.9998
0.0200
−0.0092
−0.0224
0
0
T12
0.1779
0.0061
0.9840
100.9715
3.9461
0
0
T23
0.1027
−0.9947
−0.0008
153.0923
9.9391
0
0
T34
−0.2768
0.9609
−0.0129
6.5925
−29.5228
0
0
T45
−0.1228
0.9920
−0.0309
−0.7248
−0.1750
0
0
Table 13: CPC parameters of actual Puma 560 model obtained with proposed HAY–CPC
Conversion errors
Computational time
Mean
Max
Mean
Max
Min
Std
pos.
or.
pos.
or.
10−16 m
10−15 rad
10−16 m
10−15 rad
10−5 sec
10−5 sec
10−5 sec
10−6 sec
( Zhuang et al., 1992 )
0.6966
0.3861
2.0347
1.2921
8.24
13.96
7.73
6.39
Proposed
0.9007
1.8921
2.8678
3.5955
20.08
43.04
19.25
14.43
Table 14: Comparison of HAY–CPC based on ( Zhuang et al., 1992 ) and proposed conversion algorithms: Position and orientation errors for the PUMA 560 robot across 10000 configurations and computational time over 10000 runs
POE–DH
POE–CPC
POE–HAY
HAY–POE
CPC–HAY
HAY–CPC
Mean
pos., ×10−16 m
4.1287
2.1588
2.4652
3.4980
2.7606
0.9007
orient., ×10−15 rad
1.9661
2.4131
0.5394
0.3753
0.5881
1.8921
Max
pos., ×10−16 m
12.4886
8.5260
9.5718
8.1748
6.2076
2.8678
orient., ×10−15 rad
4.2357
4.2511
2.4345
1.4091
1.6258
3.5955
Table 15: The comparison of proposed conversion with previously discovered: conversion errors of position and orientation for PUMA 560 with actual parameters on 10000 configurations