We introduce CrownFusion, a latent diffusion model to generate 3D dental crown designs from geometry images, a 2D-grid encoding of surface coordinates. Departing from traditional approaches that use point clouds, our "CrownImage" representation not only unlocks the full power of image-based generative architectures, but also preserves fine geometric detail by operating at far higher spatial resolutions than point clouds to alleviate smoothing artifacts in the 3D generation. Conditioned on jointly learned embeddings of the surrounding dentition, our probabilistic diffusion model produces anatomically plausible crowns with morphological variations tailored to individual patient cases. To accommodate multiple valid designs, we propose an occlusal fit metric based on proximity to the antagonist teeth. We evaluate our method through quantitative experiments and qualitative studies involving expert testimonials. We also release the FDI 16 Crown Dataset, comprising 11,513 annotated intra-oral scans, to support future research in dental CAD.
Figures & tables
Figure 1: Overview. From left to right: (1) Input: prepared tooth (bronze) and surrounding dentition (gray) from an intraoral scan. (2) Baseline: point cloud-based methods with Poisson reconstruction yield overly smooth geometry eroding occlusal detail. (3) Ours: a diffusion transformer generates a geometry image encoding of the crown surface, which is then meshed to recover the 3D crown, preserving fine occlusal features.
Figure 2: CrownImage construction pipeline. M : crown mesh. Muv : parametrized mesh on the unit disk via boundary-fixed harmonic mapping. Muv∗ : fisheye-transformed UV mesh (inner disk expanded, outer annulus compressed). O : rasterized geometry image encoding (x,y,z) and α . M∗ : remeshed crown recovered by triangulating O .
Figure 3: Overview of CrownFusion. Left: VAE reconstruction from geometry images. Right: conditional generation via SiT diffusion in the learned latent space.
DPM [ 10 ]
SetVAE [ 9 ]
LION [ 28 ]
FN [ 25 ]
VF-Net [ 26 ]
CrownFusion †
CD ( ×102 )
10.04
21.50
5.35
5.26
1.21
0.02
EMD ( ×102 )
43.98
59.24
22.85
33.67
6.30
0.45
Table 1: We report reconstruction errors, in CD and EMD, for the FLUX-based VAE in our CrownFusion and several prior point cloud-based baselines.
Figure 4: Surface distance heatmaps to GT show VF-Net’s errors concentrated at cusps and fissures, while our geometry image VAE is close to GT across the crown surface.
Crown Similarity ↓
Bite Proximity ↓
Intersections ↓
Model
CD-L2 (mm)
10% closest
num
area (mm 2 )
DMC [ 7 ]
0.433
0.734
256
1.110
VBCD [ 20 ]
0.353
0.747
143
2.363
CrownFusion (ours)
0.412
0.733
127
0.612
GT
0.716
12
0.0437
Table 2: Comparison of CrownFusion against previous methods for dental crown design. Crown similarity is measured by Chamfer Distance (CD-L2, mm) to a dental technician selected crown. Occlusal fit is evaluated against the three nearest antagonist teeth (by mean distance of 10th-percentile closest points) and surface intersections (count out of 1,000 sampled points, and area in mm 2 ). CrownFusion achieves the best occlusal fit with fewer intersections and competitive antagonist proximity.
Figure 5: Generation comparison. Left: dental arch with prepared abutment (top) and the reference crown in context (bottom). Right: occlusal views of crowns generated by DMC, VBCD, and CrownFusion, colored by signed distance to the antagonist (blue: gap; red: intersection). VBCD shows a large uniform gap, indicating poor occlusal contact. DMC exhibits a localized intersection (red). CrownFusion achieves the closest antagonist proximity with no intersections, and preserves well-defined occlusal anatomy.
Figure 6: Generated crown samples for the same input. CrownFusion captures expected axes of variation: fissure depth, secondary fossae detail, and distolingual cusp morphology vary, while marginal ridge height and overall crown outline remain largely stable.
School of Computer Science and Technology, Zhejiang Gongshang University, Hangzhou 310018, China · Shining3D Tech Co., Ltd., Hangzhou 311200, China · School of Artificial Intelligence and Computer Science, Nantong University, Nantong 226019, China +8