Interpretable Orthogonal Latent Diffusion with Scale-Selective Uncertainty for Medical Image Super-Resolution
Organizations: School of Earth and Oceans, UWA Oceans Institute, The University of Western Australia, Crawley, WA, Australia · School of Physics, Mathematics and Computing, Computer Science and Software Engineering, The University of Western Australia, Crawley, WA, Australia
Abstract
Diffusion models are increasingly used for medical image reconstruction and super-resolution, but their samples may contain plausible fine-scale hallucinations that are difficult to identify from the reconstructed image alone. We propose Med-PODiff, a patch-wise proper orthogonal decomposition (POD) diffusion framework for brain MRI super-resolution that performs generative reconstruction in compact and interpretable local coefficient spaces. Unlike pixel-space or learned-latent diffusion models, Med-PODiff uses the POD structure to separate low-rank anatomical variation from fine-detail residual variation, enabling predictive uncertainty to be decomposed into total, coarse, and fine components. Building on this decomposition, we define a pixel-wise hallucination-risk score, , that emphasizes regions where fine-detail uncertainty dominates coarse structural uncertainty. On brain MRI, Med-PODiff outperforms representative diffusion baselines in reconstruction quality while producing well-calibrated predictive intervals, with total uncertainty detecting high-error regions at AUROC 0.954. More importantly, the decomposed uncertainty is scale-selective: coarse and fine uncertainty preferentially predict errors at the corresponding scales, with localizing fine error at AUROC . Controlled injections and retrospective Cartesian -space undersampling further support fine-detail localization and degradation robustness. The discarded POD tail is only of the retained fine-error magnitude, and Med-PODiff improves downstream segmentation consistency while requiring substantially less inference time than pixel-space diffusion.
Figures & tables
| Method | RMSE | MAE | PSNR | SSIM |
|---|---|---|---|---|
| Bicubic | 0.08980 | 0.05960 | 20.934 | 0.7508 |
| PixelDiff | 0.05201 | 0.03452 | 25.678 | 0.8988 |
| VAE-LDM | 0.05420 | 0.03597 | 25.320 | 0.8684 |
| DiT | 0.05120 | 0.03398 | 25.815 | 0.9089 |
| Full-field POD | 0.05242 | 0.03479 | 25.610 | 0.8696 |
| Med-PODiff | 0.04611 | 0.03155 | 26.720 | 0.9120 |
| Empirical coverage (%) | ||||||
|---|---|---|---|---|---|---|
| Method | CRPS | MACE | 50 | 70 | 90 | 95 |
| PixelDiff | 0.0260 | 0.0471 | 44.42 | 64.36 | 86.18 | 91.22 |
| VAE-LDM | 0.0300 | 0.0711 | 40.68 | 58.96 | 86.11 | 90.80 |
| DiT | 0.0251 | 0.0197 | 46.90 | 67.96 | 91.59 | 96.14 |
| Full-field POD | 0.0258 | 0.0367 | 45.05 | 65.28 | 87.54 | 92.47 |
| Med-PODiff | 0.0239 | 0.0107 | 47.58 | 68.95 | 90.32 | 94.50 |
| Risk score | AUROC | AUPRC | P@10 |
|---|---|---|---|
| Med-PODiff (Total UQ) | 0.954 | 0.768 | 0.610 |
| Med-PODiff (Fine UQ) | 0.951 | 0.759 | 0.600 |
| Med-PODiff (Coarse UQ) | 0.926 | 0.711 | 0.534 |
| PixelDiff | 0.892 | 0.650 | 0.576 |
| VAE-LDM | 0.855 | 0.564 | 0.560 |
| DiT | 0.903 | 0.681 | 0.587 |
| Score target | Pearson | AUROC | AUPRC | P@10 |
|---|---|---|---|---|
| 0.900 | 0.927 | 0.747 | 0.589 | |
| 0.757 | 0.901 | 0.708 | 0.527 | |
| 0.857 | 0.926 | 0.745 | 0.583 | |
| 0.396 | 0.761 | 0.332 | 0.367 | |
| 0.425 | 0.832 | 0.335 | 0.373 | |
| 0.754 | 0.906 | 0.740 | 0.570 |
| (a) Injected-detail localization | |||
|---|---|---|---|
| Score | AUROC | AUPRC | P@10 |
| Total UQ | 0.877 | 0.668 | 0.615 |
| Fine UQ | 0.901 | 0.691 | 0.701 |
| 0.926 | 0.711 | 0.735 | |
| sFRC (HR-ref.) | 0.928 | 0.701 | 0.752 |
| (b) Degradation robustness | |||
| Score | AUROC | AUROC | Gap |
|---|---|---|---|
| 0.9186 | 0.8526 | 0.0660 | |
| 0.8826 | 0.8799 | 0.0027 | |
| 0.8789 | 0.8738 | 0.0051 |
| Method | Dice | IoU | HD95 | VolErr |
|---|---|---|---|---|
| Bicubic | 0.450 (.027) | 0.291 (.022) | 53.6 (7.0) | 0.200 (.056) |
| PixelDiff | 0.742 (.035) | 0.589 (.032) | 16.2 (2.2) | 0.033 (.022) |
| VAE-LDM | 0.705 (.027) | 0.543 (.021) | 20.2 (2.0) | 0.041 (.033) |
| DiT | 0.759 (.040) | 0.611 (.042) | 14.2 (2.0) | 0.030 (.028) |
| Med-PODiff | 0.775 (.036) | 0.632 (.031) | 13.1 (1.6) | 0.021 (.029) |
Medical Image Super-Resolution
Medical image super-resolution reconstructs fine spatial detail from low-resolution scans to support clearer anatomy and more useful clinical measurements.
See all 64 papers