Reliable and grounded reporting of any computed tomography scan with FORA
Authors: Sezgin Er, Utku Turkbey, Alperen Gur, Omer Faruk Durugol, Suprosanna Shit, Murong Xu, Julia Wolleb, Jiayi Wang, Xiaoliang Wang, Hadrien Reynaud, Teodora Spasojevic, Dong Yang, Andriy Myronenko, Pengfei Guo, Yufan He, Can Zhao, Marc Edgar, Andreas Maier, Michael Moor, Mehmet Kemal Ozdemir, Daguang Xu, Bernhard Kainz, Bjoern Menze, Ibrahim Ethem Hamamci
Organizations: Forithmus, San Francisco, CA, USA · University of Zurich, Zurich, Switzerland · Istanbul Medipol University, Istanbul, Turkiye · ETH Zurich, Zurich, Switzerland · Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany · NVIDIA, Santa Clara, CA, USA · Imperial College London, London, UK
Artificial intelligence systems for computed tomography (CT) remain largely restricted to specific anatomical regions, examination types or predefined abnormalities, limiting their ability to provide comprehensive and spatially grounded interpretations. Here we present FORA, a general-purpose CT model that recognizes and spatially localizes 1,028 hierarchically organized radiological concepts and generates reports across the 28 CT protocols represented in our cohort. Trained on 304,962 routine CT examinations supervised by their accompanying reports, FORA learns to localize abnormalities without manually annotated lesions. Its architecture combines multiple-instance learning with an interpretable concept bottleneck that connects spatial evidence, radiological findings and report generation. We first developed and benchmarked the architecture on chest radiographs, achieving state-of-the-art performance, before training a separate model on three-dimensional CT examinations. On 36,619 held-out CT examinations, FORA achieved a macro area under the receiver operating characteristic curve (AUROC) of 0.918 for radiological concept recognition, exceeding the strongest of 18 existing CT models by 0.21. FORA also ranked first on three public benchmarks, outperforming Merlin on its own test set without training on that institution's data (AUROC 0.907 versus 0.826). On independent localization benchmarks for pulmonary emboli, renal masses and rib fractures, FORA's strongest spatial evidence fell within annotated lesions at rates up to 348 times greater than chance. FORA achieved more than threefold higher macro-averaged finding recall than the strongest existing report generator. These results show that a single model can combine broad abnormality recognition, spatial localization and report generation across 12 CT examination types, using routine reports without lesion-level supervision.
Figures & tables
Figure 1: FORA links CT findings to spatial evidence and report text. a , Model overview. CT images are encoded across available clinical intensity windows (Hounsfield-unit ranges that display specific tissues, such as lung, soft tissue or bone), and concept-specific attention identifies findings and their locations to guide report generation. b , Example CT examination showing spatial evidence for multiple findings. c , Image regions supporting selected findings, paired with the corresponding generated report sentences.
Figure 2: CT finding recognition and localization. a , FORA and 18 comparison models on held-out CT examinations. b , AUPRC versus the strongest alternative across 2,132 finding-CT-type pairs. c , Public benchmarks; NV-Reason-CT’s CT-RATE AUROC is from its preprint. d , Performance across 12 CT types. e , AUROC advantage over the strongest alternative by CT type. f , Localization on four datasets; hollow points indicate chance. Error bars, 95% confidence intervals. Significance from two-sided paired tests with Holm correction is marked ∗P<0.05 , ∗∗P<0.01 and ∗∗∗P<0.001 .
Figure 3: Grounded CT report generation. a , Reference and FORA reports for a validation chest CT with matched statements numbered, and FORA’s evidence. Dots mark the reference findings that each model’s report recovered, with column numbers matching the statements. b , Finding-level metrics and LLM-judge score of FORA and seven other report generators on the FORA validation set. c , The 12 most frequent report protocols. d , Performance by number of reference findings per report. e , FORA validation set, CT-RATE and Merlin. Error bars, 95% bootstrap confidence intervals. Stars, two-sided paired tests with Holm correction ( ∗P<0.05 , ∗∗P<0.01 , ∗∗∗P<0.001 ).
Figure 4: FORA cohort and report-derived supervision across 341,581 CT examinations from 238,469 patients. a , Examination counts by CT type. b , Finding co-occurrence network. c , Scanner manufacturers and models. d-f , Slice spacing, positive labels per examination and model-input extent by CT type. g , Patient age. h , Report length by CT type. i , Label frequencies across the 1,459 concepts in the finding hierarchy. j , Asserted, uncertain and denied labels per report. k,l , Tube voltage and volume CT dose index (CTDIvol).
Figure 5: FORA learns finding recognition, spatial localization and report generation from routine CT examinations and reports. a , Self-supervised teacher–student distillation across clinical intensity windows. b , Contrastive alignment of CT features with report sentences. c , Concept-specific attention learns finding recognition and spatial evidence from report-derived labels. d , Concept-guided report generation trained through supervised fine-tuning (SFT) and direct preference optimization (DPO).
List of extendeddatafigures 1 FORA on chest radiographs. a , Reference and FORA reports for an internal validation radiograph with matched statements numbered, and FORA’s evidence. Dots mark the reference findings that each model’s report recovered, with column numbers matching the statements. b , Macro AUROC on six test sets. c , AUPRC for 128 findings. d , Performance by finding category. e , Localization on four box-annotated test sets. f , Radiologist boxes and FORA’s evidence on PadChest-GR. g , Report generation. h , Recall by number of reference findings. Error bars, 95% bootstrap confidence intervals. Stars, two-sided paired tests with Holm correction ( ∗P<0.05 , ∗∗P<0.01 , ∗∗∗P<0.001 ).
List of extendeddatafigures 2 CT finding classification in every CT type. Macro AUROC, AUPRC and balanced accuracy of FORA (black) and the 18 other models of Fig. 2 (coloured) in each CT type of the FORA validation set. The number of findings is given beside each type. Error bars, 95% bootstrap confidence intervals. Stars, FORA against the best other model, two-sided paired tests with Holm correction ( ∗∗∗P<0.001 ).
List of extendeddatafigures 3 CT localization from FORA’s evidence. a , Top-focus hit and evidence overlap in FUMPE, KiTS23, RibFrac and ReXGroundingCT. Hollow points, chance. b , Every ReXGroundingCT finding category. c , ReXGroundingCT findings by annotated volume. d , FORA, RADAR and GLINT-CT on the same annotated targets, with paired differences. A model with no output for a target scores 0 there, as RADAR does for pulmonary embolism and for 8 of the 11 ReXGroundingCT categories. For overlap, each other model’s region is cut to the size of FORA’s 80% region. Error bars, 95% confidence intervals.
List of extendeddatafigures 4 CT report generation by body region, report protocol and error type. a , Finding-level metrics and LLM-judge score of the eight report generators in each of five body regions of the FORA validation set. b , CRG score and judge score in 17 report protocols. c , Pairwise judge preference between FORA and NV-Reason-CT. d , Distribution of FORA’s judge scores. e , Clinically significant errors and matched findings per FORA report. Error bars, 95% bootstrap confidence intervals. Stars, two-sided paired tests with Holm correction ( ∗P<0.05 , ∗∗P<0.01 , ∗∗∗P<0.001 ).
List of extendeddatafigures 5 Longitudinal observation and reporting in the FORA cohort. a , Patients scanned on two or more dates. b , Intervals between consecutive dates. c , Follow-up span per patient. d , Series and views per examination. e , Native, full-range and lung MIP views. f , CT type at consecutive dates. g , Report state at the next date for 12 findings. h , Findings first asserted at the third date. i , Positive rates at the second date with and without uncertain labels. j , Age at the first date. k , Patients with several dates by first year. l , CT types per patient by number of dates. m , Three-date report trajectories for four findings. n , Repeated coronary calcification labels for identical and different acquisition settings. Error bars, 95% confidence intervals. CT colours follow Fig. 4 .
List of extendeddatafigures 6 Whole-cohort CT prediction-profile groups. a , UMAP of all 341,581 examinations coloured by 16 groups of FORA prediction profiles, with patients and CT types per group. b , Prevalence (dot area) and prevalence ratio (colour) of 28 reported findings in each group. Enrichment, CT-stratified Cochran–Mantel–Haenszel tests with Benjamini–Hochberg correction.
List of extendeddatafigures 7 Regional CT prediction-profile groups. a–f , UMAP of head, chest, abdominal, neck, cardiac and spine CT coloured by six prediction-profile groups, and prevalence (dot area) and prevalence ratio (colour) of reported findings in each group. Enrichment, one-sided tests with Benjamini–Hochberg correction.
List of supplementaryfigures 1 Data preparation and finding ontology. a , CT and report preparation with patient-disjoint splits. b , Finding ontology of 1,366 labels. c , Positive reports by depth in the hierarchy. d , Labels by number of parents. e , Descendants of three example findings. Pages 2–5 list every label with its count and parents. Colours follow Fig. 4 .
Figure 14Figure 15Figure 16Figure 17
List of supplementaryfigures 2 Report generation and report labels. a , From classifier probabilities to the report plan and the writer. b , Writer training. c , Report-label extraction and its audit.
List of supplementaryfigures 3 Prompts of the report label extractors. a , Three-pass CT label extractor, used for the CT training labels and to score CT report generation. b , Refinement passes of the CT training labels. c , Chest X-ray label extractor, used for the chest radiograph training labels and to score chest radiograph report generation.
Figure 20Figure 21Figure 22Figure 23Figure 24
List of supplementaryfigures 4 Architecture of FORA. a , Pipeline for CT and chest X-ray. b , Organ-routed multiple-instance head with attention, study logit and signed evidence.
List of supplementaryfigures 5 Evaluation protocol. a , Patient-level split. b , What each set is used for. c , Test sets with their size, relation to the training data and tasks. d , Metrics for each task.
List of supplementaryfigures 6 Classifier breadth and training data. a , Average precision against prevalence for the 1,019 CT findings with at least one positive held-out patient, using one examination per patient. b , Average precision by number of positives. c , Pooled and within-CT-type AUROC. d,e , AUROC against number of training positives for CT (d) and chest X-ray (e). f,g , AUROC by organ system.
List of supplementaryfigures 7 Calibration of the FORA classifiers. a,b , Reliability over all findings for CT (a) and chest X-ray (b). c,d , The five most frequent findings for CT (c) and chest X-ray (d). e , Predicted against observed rate for each finding. f , Expected calibration error for each finding.
List of supplementaryfigures 8 External transfer of the FORA classifier. a,b , AUROC (a) and average precision (b) of FORA and Merlin for 30 findings of the Merlin test set. c,d , FORA minus Merlin for each finding. e , AUROC for renal cyst in KiTS23 and rib fracture in RibFrac, and macro AUROC on the 21 Merlin findings covered by RADAR’s released protocol. Error bars, 95% bootstrap confidence intervals. Stars, two-sided paired tests of FORA against the best other model with Holm correction, shown on the higher of the two ( ∗P<0.05 , ∗∗P<0.01 , ∗∗∗P<0.001 ).
List of supplementaryfigures 9 Subgroup robustness of the FORA classifier. a,b , Macro AUROC (a) and balanced accuracy (b) by age, sex, scanner vendor and tube voltage for CT, and by age for chest X-ray. Error bars, 95% bootstrap confidence intervals.
List of supplementaryfigures 10 Grounded findings outside the chest in FORA validation studies. For each finding, the highest-probability (left) and median-probability (right) true positive, with FORA’s evidence region outlined, and p is the FORA probability.
List of supplementaryfigures 11 Prompts of the report writers. a , CT. b , Chest X-ray.
List of supplementaryfigures 12 Preference optimization of the report writers. a , Micro-averaged recall, precision and F1 of the CT writer after supervised fine-tuning (SFT, blue) and after direct preference optimization (DPO) from the same checkpoint (black), and the share of reference findings in the plan that the report leaves out, on 500 FORA validation studies. b , Findings stated per CT report. Dashed line, reference reports. c , Reference findings left out of the CT report by region, over all 1,028 findings (number of studies in brackets). d , The chest X-ray writer after SFT and after DPO on all 28,965 internal validation studies. e , Findings stated per chest X-ray report. Plans, references and scoring are identical before and after DPO. Error bars, 95% bootstrap confidence intervals.
List of supplementaryfigures 13 Prompts of the LLM judge and the other report generators. a , LLM judge. b , Other report generators.
List of supplementaryfigures 14 Report generation examples. Each page shows one study with the reference report, FORA’s report with matching statements numbered, the report of each other generator, and their CRG and judge scores. a , FORA validation sinus CT. b , FORA validation abdominal CT. c , CT-RATE chest CT. d , Merlin abdominal CT.
Figure 36Figure 37Figure 38
List of supplementaryfigures 15 Continuous tissue information in FORA features. a–d , Measured liver attenuation, L1 bone attenuation, aortic calcification and L3 muscle attenuation against out-of-fold readouts. e–h , Within-patient changes between two scans. i , Error of target-organ, other-organ and demographic readouts. j , Correlation of measured and readout changes. k–n , Bland–Altman agreement. Error bars, 95% patient-bootstrap confidence intervals.
List of supplementaryfigures 16 Consistency of CT profiles across repeat examinations. a , Similarity of each examination to the same patient’s repeat (blue) and to matched other patients (grey). b , Repeat advantage by CT category. c , Repeat similarity by interval. d , Group retention by interval. e , Repeat advantage for same and changed site, contrast or manufacturer. f,g , Group assignment of repeat (f) and reference (g) examinations, groups as in Extended Data Fig. 6 . Error bars, 95% bootstrap confidence intervals.
Interpreting computed tomography (CT) requires review of hundreds of volumetric slices and remains time-intensive and expertise-dependent. Automated CT report generation offers a promising route to improving clinical efficiency, yet the field still lacks a generalizable CT report generation foundation model that supports multi-region reporting and remains robust across external real-world cohorts. Intrinsic inconsistencies in reporting style and diagnostic terminology across cohorts make naive joint training difficult. Here we present Astra, a generalizable CT report generation foundation model developed on 90,678 thoracoabdominal CT-report pairs collected from five sites worldwide (CTRgDB), comprising 353,671 abnormalities spanning eight organ systems. By harmonizing report style and further refining diagnostic consistency via reinforcement learning, Astra achieves style-consistent and diagnostically accurate report generation across diverse anatomical regions and institutions. Evaluated on CTRgDB and six external cohorts, Astra achieves state-of-the-art performance with a 38.4% average improvement in fine-grained diagnostic metrics (P<0.001). Deployed at external clinical sites without any site-specific fine-tuning, Astra accelerated chest report drafting by 29.6% and improved abdominal report completeness by 11.3% among junior and mid-level radiologists (P<0.001). Furthermore, Astra demonstrates broad utility as a foundation for CT AI development, improving downstream diagnostic performance and scaling vision-language pretrain through high-quality report synthesis. Overall, Astra serves as a broadly accessible clinical assistant and a pivotal infrastructure for the next generation of AI-powered healthcare. The code for Astra is publicly available at https://github.com/zh-Wang-Med/Astra.
Zhuhao Wang, Fang Chen, Chaohui Yu +19
School of Biomedical Engineering, Tsinghua University · School of Biomedical Engineering, Shanghai Jiao Tong University · DAMO Academy, Alibaba Group +5
Automated chest CT report generation remains challenging because clinically faithful reporting requires both whole-volume understanding and accurate description of localized anatomical findings. Here we developed and retrospectively evaluated MonteRET, a region-aware retrieval-enhanced framework for generating chest CT findings sections. MonteRET integrates global CT features with region-level anatomical representations, retrieves clinically relevant knowledge using predicted medical conditions and region-level vision-language alignment, and refines initial reports through a knowledge-guided report rewriting agent. We trained our model on a public cohort with 24,128 CT scans from RadGenome-ChestCT. We evaluated MonteRET on the public RadGenome-ChestCT test set of 1,564 CT scans and an external cohort of 82 CT scans from NewYork-Presbyterian/Weill Cornell Medical Center. MonteRET improved report quality, semantic similarity, and clinical efficacy compared with a matched baseline and several state-of-the-art methods. Gains were most pronounced for recall, suggesting fewer omitted findings. Human expert evaluation by radiology residents also favored MonteRET.
Yi Lin, Yihao Ding, Elana Benishay +8
Department of Population Health Sciences, Weill Cornell Medicine, New York, USA · School of Physics, Mathematics and Computing, University of Western Australia, Crawley, Australia · Department of Radiology, Weill Cornell Medicine, New York, USA +4
We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.
Andriy Myronenko, Dong Yang, Yucheng Tang +15