As clinical AI agents begin to interact with electronic health records (EHRs), large language models (LLMs) are increasingly used to evaluate their actions. But how reliably can these judges recognize clinically dangerous mistakes, especially when an agent appears to have completed its task successfully? We investigate this question using MedAgentBench by introducing controlled clinical errors into verified agent trajectories. The experiments include 416 faulty trajectories, eight error categories, and six open-weight LLM judges. By comparing each faulty trajectory with its correct counterpart, we measure whether judges genuinely recognize errors rather than simply flagging more actions as unsafe. The findings show that access to clinical evidence significantly improves judge reliability. When shown only the final answer, judges cannot distinguish errors that leave it unchanged, while flagging 56% of correct trajectories. With full trajectory information, the ability to distinguish unsafe actions from correct ones reaches a score of 0.75, and providing actual EHR responses improves discrimination by 0.39. Surprisingly, including the agent's reasoning does not improve overall performance and reduces detection of incorrectly reported clinical values by 0.18, which remain the hardest errors to detect. MedGemma performed worse than the general-purpose model and was the only judge to miss potentially dangerous medication overdoses. We also find that the benchmark's original grader accepts all 38 trajectories with an intentionally skipped laboratory check, while combining LLM judges with a rule-based checker informed by the full EHR record detects 97% of injected faults.
Figures & tables
Fig. 1: Paired fault injection. A faulty trajectory skips a required laboratory check while keeping the final answer unchanged. A judge seeing only the final answer cannot identify the missing step, whereas a judge with access to the full trajectory can examine the actions and clinical evidence to detect it.
Fig. 2: Paired fault injection. (a) An agent completes a MedAgentBench task; a verified run becomes a clean parent. (b) Each mutant copies the parent and applies one known, clinically typed fault; the dots show which rows each evidence view gives the judge (V3 also includes the agent’s reasoning). (c) The same judge condition scores parent and mutant; paired discrimination Δ counts only flags the fault causes. Verdicts in (c) are illustrative.
Fig. 3: End-to-end pipeline. Verified agent runs become clean parents; each receives single, labeled faults; every judge condition scores parents and mutants alike; analysis reports paired discrimination per fault type, view, and severity. The lower lane compares the benchmark’s grader with the strict step checker on every agent run.
ID
Fault
Edit (MedAgentBench example)
n
Ans. unch. %
Severity (rule)
F1
Wrong patient
A GET or POST uses another real patient’s MRN; edited GETs replayed
60
50
S1–S3
F2
Dose magnitude
Potassium or magnesium dose multiplied or divided by 10
18
100
S2–S3
F3
Unit swap
Dose or recorded value keeps its number but changes unit (mEq → mg)
60
100
S1–S2
F4
Ignored observation
Order placed although the lab is above threshold, or omitted although below
60
100
S0–S3
F5
Skipped precondition
The lab GET that must precede the order is deleted; the order remains
38
100
S1–S2
F6
Hallucinated observation
Reasoning or answer cites a value that contradicts the tool response
60
0
S1–S2
TABLE I: Fault taxonomy: Each mutant contains one fault. Severity ranges indicate potential harm levels, and C0 represents harmless controls.
Tier
Meaning
NCC MERP
S0
Process deviation; no plausible patient effect
A–B
S1
Reaches the patient; no harm, or monitoring only
C–D
S2
Temporary harm requiring intervention
E–F
S3
Permanent harm, life-sustaining intervention, or death
G–I
TABLE II: Severity tiers (potential harm if executed), assigned by rule.
Condition
Δ (ans. unch.)
Δ (ans. ch.)
Crit. miss
False alarm
V1–I1
− 0.01 [ − 0.03, 0.00]
0.01 [ − 0.05, 0.06]
11 [3, 21]
56 [51, 61]
V1–I2
− 0.01 [ − 0.03, 0.01]
0.00 [ − 0.06, 0.05]
21 [12, 31]
54 [49, 59]
V2–I1
0.49 [0.41, 0.57]
0.10 [0.05, 0.15]
0 [0, 0]
44 [39, 50]
V2–I2
0.46 [0.38, 0.54]
0.16 [0.11, 0.21]
0 [0, 0]
39 [34, 44]
V3n–I2
0.81 [0.75, 0.86]
0.68 [0.62, 0.73]
3 [0, 8]
7 [5, 9]
V3–I1
0.80 [0.74, 0.86]
0.69 [0.64, 0.74]
8 [4, 13]
8 [6, 11]
TABLE III: Judge performance across evidence views and instructions. Critical misses are undetected S3 errors; false alarms are correct trajectories flagged as faulty.
Contrast
Estimate
p
H1
V1: Δ (answer same) ≈0
− 0.01 [ − 0.03, 0.00]
< 0.001
H2
V3: Δ (F1–F3) −Δ (F5, F7)
0.22 [0.14, 0.29]
1.000
H3 e
V3: Δ (S3) −Δ (S0–S2)
0.16 [0.07, 0.24]
0.993
H4
F6: Δ (V3n) −Δ (V2)
0.64 [0.57, 0.71]
< 0.001
H6
V3: Δ (MedGemma) −Δ (Gemma 3)
− 0.08 [ − 0.14, − 0.02]
< 0.001
H7 e
V3: sens.(own) − sens.(other family)
− 0.10 [ − 0.15, − 0.05]
< 0.001
TABLE IV: Hypothesis tests with estimates, 95% confidence intervals, and p -values. H1, H2, H4, and H6 use Holm-adjusted p -values; H3 and H7 are exploratory.
Fig. 4: Paired discrimination by clinical error type and judge condition, averaged across judges.
Fig. 5: Paired discrimination by judge and clinical error type under V3–I2.
Judge
Δ V1–I1
Δ V3–I2
Sensitivity
False alarm
Critical miss
Paired AUROC
ECE
Qwen3 8B r
− 0.04
0.67 [0.58, 0.76]
87
13
0 [0, 0]
0.86
0.10
Qwen3 32B r
0.04
0.81 [0.76, 0.87]
89
5
0 [0, 0]
0.93
0.07
gpt-oss 20B r
− 0.01
0.69 [0.63, 0.75]
71
1
0 [0, 0]
0.81
0.19
gpt-oss 120B r
− 0.04
0.77 [0.67, 0.86]
96
14
0 [0, 0]
0.93
0.03
Gemma 3 27B
0.02
0.81 [0.76, 0.86]
85
3
0 [0, 0]
0.94
0.09
MedGemma 27B m
− 0.02
0.73 [0.68, 0.79]
78
3
33 [8, 67]
0.89
0.15
TABLE V: Performance of the six judges under V3–I2, with V1–I1 shown for comparison. Sensitivity, false alarms, and critical misses are percentages. Confidence-based metrics use scores aligned with the returned verdict. r Reasoning model; m medically tuned model.
Fault
n
Grader
Checker
Judges
Majority
F1 Wrong patient
60
100
100
98
100
F2 Dose magnitude
18
100
100
93
100
F3 Unit swap
60
100
30
99
100
F4 Ignored observation
60
100
100
78
85
F5 Skipped precondition
38
0
100
95
95
F6 Hallucinated observation
60
100
70
49
35
TABLE VI: Clinical fault detection rates for the benchmark grader, rule-based checker, and LLM judges (%).
Agent
Runs
Grader pass %
Passes flagged %
Pass and clean
gpt-oss 120B
630
48
0.7
301
Qwen3 32B
630
45
2.5
277
TABLE VII: Comparison of the benchmark grader and step checker on unmodified agent runs.
Large language model (LLM)-as-a-judge research uses language models to score, compare, and verify AI outputs as scalable alternatives to human evaluation.