Organizations: Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany · Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany · Department of Diagnostic and Interventional Radiology, School of Medicine and Health, Klinikum rechts der Isar, Technical University of Munich, 81675 Munich, Germany · Institute for Advanced Study, Technical University of Munich, 85748 Garching, Germany · 

Abstract

Large, well-annotated datasets are essential for developing medical artificial intelligence models, yet data sharing is often restricted by privacy regulations. Synthetic images may help address this limitation if they preserve diagnostic information while reducing the risk of reproducing patient data. We developed a diffusion autoencoder-based framework for class-conditional synthetic chest CT generation that incorporates latent-space distance filtering to reduce the likelihood of regenerating training samples. A diffusion autoencoder was trained on the public RSNA 2020 Pulmonary Embolism (PE) dataset. PE-positive and PE-negative images were synthesized by sampling latent representations from class-specific kernel density estimates. Samples with a nearest-neighbor latent-space distance below a predefined threshold were rejected. To assess diagnostic utility, ResNet-50 classifiers were trained across 10 independent runs using real, synthetic, or mixed real-synthetic datasets. Performance was evaluated on a held-out real test set using the area under the receiver operating characteristic curve (AUC), with DeLong 95% confidence intervals (CIs). Models trained on synthetic data achieved an AUC of 0.862 (95% CI, 0.851-0.874), only slightly lower than models trained on real data (AUC = 0.872, 95% CI, 0.861-0.883) and mixed real-synthetic data (AUC = 0.865, 95% CI, 0.855-0.876). These differences were statistically significant (p < 0.05) but small in absolute terms. A nearest-neighbor copy-detection analysis of 38,000 synthetic slices found no direct copies of real training images. These findings indicate that the synthetic CT images preserve diagnostically meaningful information for image-level PE classification while incorporating measures intended to enhance privacy awareness and reduce similarity to real patient data.

Figures & tables

Explore similar work

Jul 22, 2026

DS@GT ARC at ImageCLEFmed GANs 2026: Geometric Filtering for Privacy-Preserving CT Slice Generation

We present a privacy-preserving framework for synthetic lung CT slice generation developed for the Image-CLEFmed GANs 2026 challenge. The approach combines Optimal Transport Conditional Flow Matching with privacy-oriented training and a post-generation "Supervisor" pipeline that filters generated candidates in learned geometric latent spaces using autoencoder embeddings, Determinantal Point Processes, and Stein Kernel Thinning. Official results show a strong realism-privacy trade-off, with the best-performing model achieving a Privacy Preservation Score of 0.549 and competitive visual fidelity with an FID of 0.3290. While the proposed geometric filtering substantially reduces nearest-neighbor memorization and membership-inference leakage, persistent patient re-identification scores indicate that preventing direct image copying is not sufficient to remove deeper patient-specific anatomical identity, highlighting an important frontier for future privacy-preserving medical image generation.
Jul 3, 2026

CONFLUX: A Latent Diffusion Model for 3D Chest-CT Synthesis with RL Post-Training

Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning. We present CONFLUX, a latent diffusion model for chest computed tomography (CT): a 3D variational autoencoder compresses each volume, and a rectified-flow transformer generates in the latent space. Generation is conditioned on structured radiological metadata (18 abnormality findings, sex, age, and reconstruction kernel) through adaptive layer normalization. The model leads strong volumetric baselines on tri-planar Frechet distance (FID 32.3 vs. 74.6 for MAISI) while exposing direct control over clinical attributes. To strengthen that control we add an online reinforcement-learning post-training stage (group-relative policy optimization) that rewards how reliably a classifier recovers the requested findings from each generated volume. Judged by a separate, independent classifier, post-training removes 47% of the shortfall relative to real-scan reliability. We release the model and a ~200k synthetic chest-CT dataset with conditioning metadata spanning a wide variety of clinical findings.
Jul 16, 2026

Demographically-Conditioned Synthetic Medical Images for Bias Mitigation and Bias Detection in Disease Classifiers

Per-subgroup fairness audits of medical image classifiers face a sample-size problem: minority subgroups in held-out test sets have so few samples that the resulting confidence intervals on per-subgroup performance are wider than the bias the audit is meant to detect. We argue that a demographically-conditioned synthetic generator can do both: mitigate bias on the training side and detect bias on the evaluation side. Working on COVID-19 chest CT classification with an end-to-end fine-tuned Stable Diffusion 2.1 generator, we make two findings. For bias mitigation (training), a demographically-balanced synthetic cohort is most useful as a pretraining prior, not as joint augmentation: with the same fixed data, sequential pretraining followed by fine-tuning substantially outperforms joint augmentation, and the resulting classifier surpasses the full-real baseline at \sim$$100\times real-data efficiency. For bias detection (evaluation), across five synthetic minority cohorts and five classifier seeds, the synthetic estimator reproduces the subgroup ranking of a well-powered real oracle (Spearman ρ=1.00ρ= 1.00 on MCC and Recall) and gives the more reliable per-cell estimate where the small real test set runs out of samples. The synthetic cohort is therefore most useful in exactly the cells that fairness audits care about, as both a fix for and a measure of subgroup bias.