eess.IVNov 24, 2026

Diagnostically Meaningful, Privacy-aware Synthetic Chest CT via Class-Conditional Latent Sampling in Diffusion Autoencoders

Authors: Johannes B. Thalhammer, Kacper Ogórek, Tina Dorosti, Sebastian Peterhansl, Daniel Frey, Zijin Huang, Theresa Hiu, Tobias Lasser, 

Organizations: Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany · Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany · Department of Diagnostic and Interventional Radiology, School of Medicine and Health, Klinikum rechts der Isar, Technical University of Munich, 81675 Munich, Germany · Institute for Advanced Study, Technical University of Munich, 85748 Garching, Germany · 

Abstract

Large, well-annotated datasets are essential for developing medical artificial intelligence models, yet data sharing is often restricted by privacy regulations. Synthetic images may help address this limitation if they preserve diagnostic information while reducing the risk of reproducing patient data. We developed a diffusion autoencoder-based framework for class-conditional synthetic chest CT generation that incorporates latent-space distance filtering to reduce the likelihood of regenerating training samples. A diffusion autoencoder was trained on the public RSNA 2020 Pulmonary Embolism (PE) dataset. PE-positive and PE-negative images were synthesized by sampling latent representations from class-specific kernel density estimates. Samples with a nearest-neighbor latent-space distance below a predefined threshold were rejected. To assess diagnostic utility, ResNet-50 classifiers were trained across 10 independent runs using real, synthetic, or mixed real-synthetic datasets. Performance was evaluated on a held-out real test set using the area under the receiver operating characteristic curve (AUC), with DeLong 95% confidence intervals (CIs). Models trained on synthetic data achieved an AUC of 0.862 (95% CI, 0.851-0.874), only slightly lower than models trained on real data (AUC = 0.872, 95% CI, 0.861-0.883) and mixed real-synthetic data (AUC = 0.865, 95% CI, 0.855-0.876). These differences were statistically significant (p < 0.05) but small in absolute terms. A nearest-neighbor copy-detection analysis of 38,000 synthetic slices found no direct copies of real training images. These findings indicate that the synthetic CT images preserve diagnostically meaningful information for image-level PE classification while incorporating measures intended to enhance privacy awareness and reduce similarity to real patient data.

Figures & tables

Explore similar work

CardsList
  1. DS@GT ARC at ImageCLEFmed GANs 2026: Geometric Filtering for Privacy-Preserving CT Slice Generation

    Jul 22, 2026Eric Regina, Richard Arnaud, Samir Hadi CisnerosPrivacy-Preserving MLMedical Image Synthesis

  2. CONFLUX: A Latent Diffusion Model for 3D Chest-CT Synthesis with RL Post-Training

    Jul 3, 2026Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge +1Latent Diffusion ModelsMedical Image Synthesis

  3. Demographically-Conditioned Synthetic Medical Images for Bias Mitigation and Bias Detection in Disease Classifiers

    Jul 16, 2026Mahmoud Ibrahim, Bart Elen, Chang Sun +2Synthetic Data PretrainingAlgorithmic Fairness