FlowersBench: A FluidFlower-Inspired Dataset for Benchmarking Carbon Storage Surrogates Across Geological Structures
Authors: Farah Rabie, Hannah Menke, Florian Doster, Amy Gough, Ahmed H. Elsheikh
Organizations: Institute of GeoEnergy Engineering (IGE), School of Energy, Geoscience, Infrastructure & Society, Heriot-Watt University, Edinburgh, EH14 4AS, UK
Machine learning surrogates are emerging as a computationally efficient tool for uncertainty quantification in geological carbon storage (GCS). Geological structure constitutes a major source of uncertainty; however, existing benchmark simulation datasets predominantly vary petrophysical and operational parameters within a fixed geological setting. Generalisation to unseen geological structures therefore remains largely unexplored. We introduce FlowersBench, a benchmark dataset of 5,000 two-dimensional, reservoir-scale CO2 storage simulations across 244 structural geometries. The geometries are sampled from an in-house structural generator inspired by the FluidFlower experiments and Case B of the 11th Society of Petroleum Engineers Comparative Solution Project (SPE11B). Each simulation is run with Open Porous Media (OPM) Flow over a 50-year injection period and a 500-year post-injection monitoring period. Test geometries are withheld from training to assess generalisation to unseen structural geometries. Two additional subsets support evaluation under structural shift. The first extends the parameter ranges of the structural generator beyond those used for training, and the second introduces an unseen topology of multiple parallel faults. A baseline U-Net surrogate is trained to predict CO2 gas saturation. In representative test cases, the surrogate recovers the main migration pathways, including lateral spreading beneath low-permeability layers and upward flow along fault damage zones, with errors concentrated near the plume boundary. Under both structural shifts, prediction error exceeds that on the held-out geometries, and the increase in relative error is greater for the unseen fault topology. FlowersBench is publicly available and provides a common basis for evaluating GCS surrogates across geological structures.
Figures & tables
Figure 1: Four-stage workflow used to generate FlowersBench : geometric realisation, property assignment, well placement, and case simulation in OPM Flow.
Figure 2: Examples of stratigraphic layering sampled by the in-house structural generator, shown without faults. Colours denote distinct stratigraphic layers. Coordinates are normalised generator coordinates, with x=0 at the right of each panel and z the normalised elevation.
Figure 3: Fault styles sampled by the in-house structural generator: (a) a single fault, (b) a fault pair with a raised central block, and (c) a fault pair with a lowered central block (graben). Fault damage zones are shown in purple and fault cores in a darker shade. Coordinates as in Figure 2 .
Immobile non-wetting saturation, Sn,imm (-)
0.1
Maximum capillary pressure, pcap,max (Pa)
3×107
Dispersivity, E (m)
10
Rock specific heat capacity, cs (kJ kg -1 K -1 )
0.85
Rock density, ρs (kg m -3 )
2500
Table 1: Fixed petrophysical properties, following the SPE11B benchmark [ 25 ] . Values apply to all facies except the impermeable basal layer, for which Sn,imm and E are set to zero.
Facies
ϕ (-)
K (mD)
Sw,imm (-)
κs (W m -1 K -1 )
Permeable
P1
0.10
0.10
0.32
1.90
P2
0.20
101.3
0.14
1.25
P3
0.20
202.7
0.12
1.25
P4
0.20
506.6
0.12
1.25
P5
0.22
709.3
0.12
1.10
Table 2: Population means for the stratigraphic facies. Facies are assigned in order from the bottom of the sequence upward, and sampled values are clipped to the bounds listed for each class.
Facies
ϕ (-)
K (mD)
Sw,imm (-)
κs (W m -1 K -1 )
Damage zone
D1
0.34
1800
0.11
0.26
D2
0.32
1500
0.12
0.28
Non-sealing fault core
C1
0.32
1000
0.12
0.26
C2
0.30
800
0.13
0.28
Table 3: Population means for the fault facies. Populations are indexed by the order in which the faults were inserted, and sampled values are clipped to the bounds listed.
Parameter
Normalised
Physical
Minimum permeability, Kmin
-
0.05 mD
Minimum layer thickness, tmin
0.15
150 m
Layer boundary buffer, δl
0.05
50–150 m
Domain boundary buffer, δdomain
0.30
900 m
Fault exclusion buffer, δf
0.05
150 m
Low-permeability layer buffer, δz
0.05
50 m
Table 4: Parameters for stochastic well placement, in normalised generator coordinates and physical units. Horizontal and vertical lengths scale by 3000 and 1000, respectively, so δl and δw , which act in both directions, span a range of physical values.
Period
Duration, Δt (yr)
Max. time step (yr)
Injection rate, q (kg s -1 )
Equilibration
999.9
1.0
0
Settling
0.1
0.1
0
Injection
50
0.1
0.035
Post-injection monitoring
500
0.1
0
Table 5: Simulation schedule, identical for all cases.
Figure 4: Stratigraphic layering across the 244 structural geometries: (a) number of stratigraphic layers per geometry, and (b) example geometries with three to six permeable layers. Coordinates as in Figure 2 .
N
Mean
Median
Min
Max
Stratigraphic layers per geometry
244
7.48
7
6
9
Permeable layers per property realisation
1,146
4.48
4
3
6
Permeability (mD)
Permeable layers
5,139
271.6
180.0
0.076
1076.0
Low-permeability layers
2,292
0.0013
0.0012
0.0008
0.0019
Sealing fault cores
576
0.0012
0.0011
0.0008
0.0025
Table 6: Summary statistics of the sampled structure and permeability. N is the number of geometries, property realisations, or regions summarised in each row.
Figure 5: Distributions of (a) permeability, on a logarithmic scale, and (b) porosity by facies class across the 1,146 property realisations. Each region contributes one value, and each histogram shows the fraction of regions of that class in each bin. Sealing fault cores are shown as a dashed outline.
Figure 6: Density of the 5,000 sampled injection-well locations. Coordinates are physical, with x measured from the left boundary of the domain and z increasing downward from the top.
Figure 7: CO 2 plume extent across the 5,000 simulation cases, defined by Sg>0.01 : (a) distribution at 550 years, and (b) median over time, with the interquartile range and 50 randomly selected individual cases. The dashed line marks the end of injection.
Figure 8: Three example cases, (a)–(c). The top row shows the facies classes of each structural geometry, and the bottom row shows the gas saturation Sg at 550 years. Coordinates as in Figure 6 . Stars mark the injection wells.
Metric
Unit
Mean
Median
Min
Max
Plume extent at 550 years
Sg>0.01
km 2
0.60
0.60
0.22
0.96
Sg>0.1
km 2
0.29
0.29
0.04
0.68
Maximum pressure increase, ΔPmax
bar
196.8
178.5
83.2
648.7
Maximum temperature decrease, ΔTmax
∘ C
52.1
52.9
39.0
56.5
Mean dissolved CO 2 at 550 years, Rsw
sm 3 sm -3
3.28
3.27
1.76
5.23
Table 7: Summary statistics of outcome metrics across the 5,000 simulation cases. Changes in pressure and temperature are relative to the initial state at t=0 and are taken over all grid cells and reporting times.
Figure 9: Training (solid) and validation (dashed) losses over 100 epochs: (a) total loss (Equation 11 ) and (b) the component losses, LMSE and Ledge . The vertical axis is logarithmic.
Figure 10: Inputs and results for the test case with the median plume-masked MAE. Top row: the five input fields, namely porosity, permeability, the well mask ( well rate , in kg s -1 ), and the pressure and temperature fields at t=0 , with all fields except the well mask in normalised units. Middle and bottom rows: target and predicted gas saturation at five reporting times, from 20 to 550 years. Axes show cell indices of the downsampled 256×64 grid, and stars mark the injection well.
Figure 11: Plume-masked (a) MAE, (b) bias, and (c) relative L2 error for the test set: geometry-balanced mean (line) and 25–75% and 5–95% ranges across the 974 test cases (bands). The dashed line marks the end of injection.
Figure 12: Signed gas saturation error (prediction minus target) for the test cases with the lowest, median, and highest plume-masked MAE (rows) at five reporting times (columns). Values above each panel are domain-averaged signed errors, which, unlike the plume-masked bias, include the small non-zero predictions outside the plume. Axes as in Figure 10 , and stars mark the injection wells.
Figure 13: Target (solid blue) and predicted (dashed red) plume fronts, defined by Sg=0.01 , for the test cases with the lowest, median, and highest plume-masked MAE (rows) at 10, 20, and 250 years (columns). Low-permeability regions are shown in grey, and axes are as in Figure 10 .
Figure 14: Example structural geometries from the extended-range subset, each with a fault pair and a supplementary fault. Colours and coordinates as in Figure 3 .
Figure 15: Example structural geometries from the parallel-fault subset, each with two to four parallel faults within a faulted region bounded by unfaulted layers. Colours and coordinates as in Figure 3 .
Figure 16: Geometry-balanced plume-masked (a) MAE, (b) bias, and (c) relative L2 error for the test set and the two structural-shift subsets. The dashed line marks the end of injection.
Figure 17: Signed gas saturation error for the extended-range cases with the lowest, median, and highest plume-masked MAE, as in Figure 12 .
Figure 18: Signed gas saturation error for the parallel-fault cases with the lowest, median, and highest plume-masked MAE, as in Figure 12 .
Appendix figures & tables8 assets
Supplementary material from the paper’s appendix.
Appendix
Parameter
Distribution / value
Description
Stratigraphy
Domain
[0,2.8]×[0,1.2]
Normalised generator domain
Initial horizons
{3,4,5}
Horizons of the faulted sequence
Basal-unit horizons
{2,3}
Horizons subdividing the basal unit beneath the faulted sequence
Horizon amplitude, ak
Uniform(0.01,0.10)
Fraction of the height of the region being divided
Horizon frequency, fk
Uniform(0.2,0.5)
Sinusoidal cycles across the domain width
Appendix
Table 8: Sampling distributions of the in-house structural generator. Integer sets are sampled uniformly. Lengths and elevations are in normalised generator coordinates; dips are physical angles.
Main dataset
Extended-range
Parallel-fault
Structural geometries
244
18
18
Property realisations
1,146
20
18
Simulation cases
5,000
50
50
Stratigraphic layers per geometry
6–9
8–10
9–13
Faults per geometry
1–3
3
2–4
Permeable layers per property realisation
3–6
5–7
6–10
Appendix
Table 9: Characteristics of the two structural-shift subsets compared with the main dataset.
Parameter
Main dataset
Extended-range subset
Initial horizons
{3,4,5}
{6,7,8}
Horizon amplitude, ak
Uniform(0.01,0.10)
Uniform(0.008,0.010)
Horizon frequency, fk
Uniform(0.2,0.5)
Uniform(0.5,0.8)
Horizon phase, ψk
Uniform(−0.01,0.01)
Uniform(−0.02,−0.01)
Lower bound of base height fraction
0.10
0.12
Basal-unit horizons
{2,3}
1
Appendix
Table 10: Generator parameters changed for the extended-range subset, relative to the main dataset (Table 8 ).
Figure 19: Injection-well locations of the extended-range subset, shown over the density of well locations in the main dataset. Coordinates as in Figure 6 .
Figure 20: Input fields of the extended-range cases with the lowest, median, and highest plume-masked MAE averaged over reporting times (rows): porosity, permeability, the well mask, and the pressure and temperature fields at t=0 , with all fields except the well mask in normalised units. Axes as in Figure 10 , and stars mark the injection wells.
Parameter
Distribution / value
Number of faults
{2,3,4}
Fault locations
Uniform(0.8,2.0) , at least 0.15 apart
Dip angle
Uniform(55∘,65∘) in normalised coordinates (25–36 ∘ physical), shared by all faults; dip direction random
Throw
Uniform(0.02,0.08) , independently per fault
Downthrown side
Left or right, independently per fault
Damage-zone thickness
0.05
Appendix
Table 11: Generator parameters for the parallel-fault subset. Where two values are given, they correspond to the low and high positions of the faulted tier.
Figure 21: Injection-well locations of the parallel-fault subset, shown over the density of well locations in the main dataset, as in Figure 19 .
Figure 22: Input fields of the parallel-fault cases with the lowest, median, and highest plume-masked MAE averaged over reporting times (rows), as in Figure 20 .
Systems and Computer Engineering and High Performance Computing Center, NACAD - COPPE, Federal University of Rio de Janeiro · Civil Engineering and High Performance Computing Center, NACAD - COPPE, Federal University of Rio de Janeiro · Mechanical Engineering and High Performance Computing Center, NACAD - COPPE, Federal University of Rio de Janeiro +1