Abstract

The Smart Buildings Challenge asks for one HVAC control policy that runs office buildings and weather it has never seen, from the building's metadata and sensor streams alone. Our controller sees no data from the target building before it runs and is not tuned per building; its few global constants were set on development scenarios. Each zone has a first-order grey-box model that starts from coefficients computed from the floor plan and is updated online by recursive least squares, and a planner and a closed-form mapping turn the models into plant commands. On two sets of buildings and weather that we generated, a validation set and a stress set with real-year weather, it scores 0.145 and 0.159 times the starter kit's PID baseline, and 0.095 times on a holdout built after all versions were fixed and scored once. It improves on every building, also against our two implementations of ASHRAE Guideline 36: per set it scores 0.60 to 0.71 times a basic version and 0.83 to 0.96 times one partly tuned on the public leaderboard, which wins one of 54 scenarios; with a 5 °C frost target for empty zones on both, the margin over the tuned version shrinks to 1.4% on the stress set, where one of six buildings is 0.2% worse. In an ablation on a reduced-order model, removing both the floor-plan prior and online identification costs 28%, 20% and 42% on the validation, stress and holdout sets, far more than the two effects combined: either source of building-specific information recovers most of what is lost without both. On one office floor in a second simulator, BOPTEST, this does not carry over: with identification on, the two priors give similar results, but the floor-plan prior alone, with constants fitted on the competition's simulator, is the least stable arm. These simulation results motivate testing floor-plan-initialised adaptive control in buildings that have drawings but no operating data.

Figures & tables

Appendix figures & tables8 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Oct 2, 2024

The Smart Buildings Control Suite: A Diverse Open Source Benchmark to Evaluate and Scale HVAC Control Policies for Sustainability

Commercial buildings account for 17% of U.S. carbon emissions, with roughly half of that from Heating, Ventilation, and Air Conditioning (HVAC). HVAC devices form a complex thermodynamic system, and while model predictive control and reinforcement learning have been used to optimize control policies, scaling to thousands of buildings remains a significant unsolved challenge. Most current approaches are over-optimized for specific buildings and rely on proprietary data or hard-to-configure simulators. We present the Smart Buildings Control Suite, the first open source interactive HVAC control benchmark with a focus on solutions that generalize across building. It has 3 components: real-world data from 11 buildings over 6 years, a lightweight data-driven simulator, and a modular Physically Informed Neural Network (PINN) building model. The buildings span multiple climates, management systems, and sizes, and both the simulator and PINN easily transfer to new buildings, ensuring solutions using this benchmark are robust to these factors and only reliant on fully scalable building models. This represents a major step towards scaling HVAC optimization from the lab to buildings everywhere. To facilitate use, our benchmark is compatible with the Gym standard, and our data is available at our webpage. Code at https://github.com/google/sbsim
Oct 13, 2026

The Smart Buildings Challenge: Learning Foundation Models for Real-World Optimization at Scale

Buildings cause nearly 40% of carbon emissions in the US. Of total building emissions, HVAC systems are responsible for approximately 40-60% and account for 15% of global energy consumption. Despite advances in artificial intelligence, most buildings still operate as inefficiently as they did decades ago. Building optimization, perhaps more so than any other optimization problem, has enormous potential for Machine Learning (ML) driven impact on climate change, in both the short and long term. One of the biggest obstacles for building optimization is the lack of policy transfer. Most building control systems, whether simulation or learning based, don't generalize: they only work well for the building they were developed for, but not for other buildings. To solve this problem, we propose a challenge for the development of building foundation models that easily adapt to new buildings with minimal configuration and thereby enable building optimization to scale across the globe. Participants will build control policies on a set of simulated buildings, and have their policies evaluated on an unseen set of buildings. The buildings vary in size, layout, weather, material properties, and HVAC system. Successful outcomes from this initiative promise a massive leap forward in global sustainability efforts and demonstrate the great potential of ML to combat climate change.
Oct 14, 2026

One Agent per Zone: Decentralised Active Inference under Partial Observability for Multi-Zone HVAC Control on Edge Hardware

Multi-zone HVAC control is a shared-resource problem: zones on a floor share one fan and cooling coil, so each zone's demand affects its neighbours and the building's peak power. One controller per zone scales well and isolates faults, but each controller then observes only its own zone, not the shared air loop. In this work, we present a decentralised controller that assigns each zone an independent active-inference agent, which plans by minimising expected free energy and learns its zone dynamics online. The agents exchange no messages, so none depends on peers or a coordinator; each accounts for the unobserved coupling through a latent disturbance and a congestion signal derived from the metered power of the other floors. Fifteen agents are evaluated in EnergyPlus on a Sinergym office building against three rule-based controllers and three MADDPG fleets, one given the same floor meters. On five noisy weather years unseen during training, the fleet attains the lowest mean building peak (88.3 kW, 3 to 17 % below the baselines) and staggers the floor peaks better than any baseline, with a coincidence factor (building peak over the sum of the floor peaks) of 0.929 versus 0.936 to 0.994. Compared with a reactive rule at similar comfort (0.912 versus 0.916), it lowers the sum of monthly peaks, on which demand charges are billed, by 33 kW (4 %) in every year, at the cost of about 10 % more energy. It costs 9% less per year than the proactive rule (at lower comfort) and 1% less than the MADDPG fleet given the same floor meters, in every test year. The whole fleet runs on a single low-cost Raspberry Pi 5, closing the observation-to-action loop over MQTT in 442 ms at p95, far below the 15-minute control step.