Evaluating Cine and Tagged MRI-to-Speech Synthesis with Complementary Metrics and MRI-Free Controls
Authors: Karlo Vrancic, Fangxu Xing, Jiachen Zhuo, Maureen Stone, Jerry L. Prince, Jonghye Woo
Organizations: Dept. of Radiology, Mass General Brigham and Harvard Medical School, Boston, MA, USA · Data Science, Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA · Dept. of Radiology, University of Maryland School of Medicine, Baltimore, MD, USA · Dept. of Neural and Pain Sciences, University of Maryland School of Dentistry, Baltimore, MD, USA · Dept. of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
Relating tongue motion measured with dynamic MRI to the speech it produces could inform rehabilitation after glossectomy. Prior studies have translated cine or tagged MRI into log-mel spectrograms and used the two-dimensional Pearson correlation between predicted and recorded spectrograms (Corr2D) to quantify the acoustic information captured by each imaging modality. However, Corr2D has not been calibrated against MRI-free predictors that preserve basic acoustic structure. Our contribution is an evaluation framework for speech synthesis from cine MRI, tagged MRI and their combination; the synthesis network is held fixed. On identical leave-one-subject-out folds, we compare four trained input configurations with two MRI-free controls: a static mean-spectrum baseline and a time-aligned cohort template. Across 44 subjects (18 after glossectomy) producing two utterances, the cohort template, which never sees an MRI, reached a Corr2D of 0.745 and 0.664. The static baseline, which contains no timing, reached 87 to 89% of that score. No trained configuration outperformed the template on Corr2D, a cepstral distance or ESTOI; seven of the eight fell significantly short on Corr2D. For cine MRI this held across three positional encodings, an encoder temporal-attention module and a training objective matched to the metric. Cine and tagged MRI differed consistently within subjects, although the direction depended on the metric. Absolute Corr2D alone therefore does not show that a model recovers acoustics from the MRI. The two controls are a reusable method: any study can compute them from its own training recordings, so a model's margin over them measures what its images contribute.
Figures & tables
Figure 1: The image-to-spectrogram network and the two MRI-free controls. Top: one backbone is held fixed across all four input configurations, which differ only in how many image channels are stacked. Per-frame patch tokens carry a graph-Laplacian positional encoding. They are pooled to one vector per frame and resampled along time to the target length; a decoder then emits 64 mel channels. Bottom: the controls reach the same evaluation from the training subjects’ recorded spectrograms alone, without MRI. Both controls and the trained models receive the held-out subject’s duration. MRI frames, spectrograms and waveforms are real, from the held-out subject of Fig. 4 .
Figure 2: Every primary-protocol Corr2D in this paper, one axis per utterance. Grey diamond: the static mean-spectrum baseline (no images, no timing). Black diamond and dashed line: the cohort template (no images; the average speaker). Blue dots: the twelve trained runs of Sec. 3.3 , spanning 0.692–0.740 on “a souk” and 0.566–0.645 on “a geese”. All lie below the template in the mean; the two nearest (open circles), “a souk” cine under either objective, are statistically level with it ( p=0.36 ). Grey bar: the template’s Corr2D on the same recordings under other target renderings (Sec. 3.4 ); these values are not comparable with the dots.
Figure 3: (a,b) The four trained configurations against the two MRI-free controls, solid fill for “a souk” and hatched for “a geese”. No configuration beats the template on either metric. On “a geese” only cine MRI is significantly better than the static mean-spectrum baseline. (c) Each prediction is compared with a matched reference αY+(1−α)B whose fidelity to the target equals the prediction’s own (grey curve; shaded region is above it). All 28 predictions fall below their matched reference. Points are 7 subject-tasks from a separate inference run (Sec. 3.5 ).
“a souk” ( n=37 )
“a geese” ( n=41 )
Input
Corr2D ↑
LMCD ↓
ESTOI ↑
Corr2D ↑
LMCD ↓
ESTOI ↑
cine (1 ch)
0.7393 (0.36)
79.96 (0.50)
0.1172 (0.008)
0.6262 ( < .001)
88.19 ( < .001)
0.0678 ( < .001)
tagged, 1 orientation (1 ch)
0.7275 (0.011)
83.45 (0.005)
0.1289 (0.21)
0.6014 ( < .001)
91.64 ( < .001)
0.1102 (0.002)
tagged, 2 orientations (2 ch)
0.7053 ( < .001)
86.30 ( < .001)
0.1117 (0.017)
0.5856 ( < .001)
92.51 ( < .001)
0.1037 ( < .001)
cine + tagged fusion (3 ch)
0.7099 ( < .001)
85.69 ( < .001)
0.1093 (0.068)
0.5927 ( < .001)
91.91 ( < .001)
0.0822 ( < .001)
cohort template
0.7445
79.38
0.1466
0.6638
84.12
0.1632
Table 1: Full leave-one-subject-out results with identical folds and training protocol, against the two MRI-free controls. Parenthesized values are paired Wilcoxon p against the template. Best per column in bold . LMCD is comparable across these rows only; LMCD and ESTOI were not computed for the static baseline. The cohort template is best in every column; no configuration exceeds it.
Figure 4: One held-out healthy subject, “a souk”. The recorded spectrogram carries temporal events that none of the predictions recover. The cohort template, the cine MRI prediction and the tagged MRI prediction are visually the same object; the template scores the highest Corr2D of the three. This subject, among the better-scoring folds, is shown for legibility. It comes from the same separate inference run as Fig. 3 c.
Real-time magnetic resonance imaging (rtMRI) of speech production enables non-invasive visualization of dynamic vocal-tract motion and is valuable for speech science and clinical assessment. However, rtMRI is fundamentally constrained by trade-offs among spatial resolution, temporal resolution, and acquisition speed, often leading to undersampled k-space measurements and degraded reconstructions. We propose SIREM, a speech-informed MRI reconstruction framework that uses synchronized speech as a cross-modal prior. The central idea is that vocal-tract configurations during speech are correlated with the produced acoustics, making part of the image content predictable from audio. SIREM models each frame as a fusion of an audio-driven component and an MRI-driven component through a spatial weighting map. The audio branch predicts articulator-related structure from speech, while the MRI branch reconstructs complementary content from measured k-space data. We further introduce a learnable soft weighting profile over spiral arms, enabling a differentiable study of how k-space arm usage interacts with speech-informed fusion. This yields a unified multimodal formulation that combines audio-driven prediction, MRI reconstruction, and sampling adaptation. We evaluate SIREM on the USC speech rtMRI benchmark against standard baselines, including gridding, wavelet-based compressed sensing, and total variation. SIREM introduces a speech-informed reconstruction paradigm that operates in a substantially higher-throughput regime than iterative methods while preserving anatomically plausible vocal-tract structure. These results establish an initial benchmark for multimodal speech-informed rtMRI reconstruction and highlight the potential of synchronized speech as an auxiliary prior for fast reconstruction. The source code is available at https://github.com/mdhasanai/SIREM
Md Hasan, Nyvenn Castro, Daiqi Liu +6
1Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany · Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany · 3Institut für Informationsverarbeitung, Leibniz Universität Hannover, Hannover, Germany +1
Real-time MRI (rtMRI) captures the dynamics of the entire vocal tract during speech, but labeled data are scarce and the modality - single-slice, grayscale, low-resolution - differs substantially from the natural videos that video foundation models are trained on. We introduce Arti-JEPA, a joint embedding predictive architecture to model vocal tract rtMRI by continuing its self-supervised objective on about 62h of unlabelled vocal-tract videos, and evaluate the frozen representation on three tasks: cross-domain phoneme prediction (on typical speakers), fluent-vs-disfluent classification (a corpus containing stuttered speech), and characterizing pre/post-operative transfer (after partial glossectomy). Three key findings emerge. (1) A temporal video prior decisively outperforms per-frame image encoders, and latent prediction (V-JEPA) is at least as strong as pixel reconstruction (VideoMAE), with the edge on fine-grained phonemes. (2) Domain adaptation is task-dependent: it roughly doubles cross-domain phoneme prediction κ (to 0.352) but does not help binary stuttering classification. (3) Arti-JEPA was able to recover phoneme signal from pre/post glossectomy speech --- an in-domain probe decodes patients at least as well as a typical speaker, indicating that the residual transfer gap is cross-speaker/domain misalignment, not surgical signal loss, and post-operative decoding does not fall below performance on pre-operative speech. Together, these position a frozen, domain-adapted rtMRI encoder as a reusable measurement tool for articulatory and clinical speech science.
Hong Nguyen, Sean Foley, Christina Hagedorn +4
Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, USA · Department of English, College of Staten Island, City University of New York, New York, NY, USA · Department of Linguistics, University of Potsdam, Germany +1
Segmenting vocal tract articulators in real-time MRI (rtMRI) is a challenging dynamic image segmentation problem characterized by low contrast, rapid motion, and limited spatial resolution. However, while rtMRI acquisitions may provide synchronized acoustic signals, existing methods discard this information, and the few multimodal approaches that incorporate audio cannot be deployed when audio is unavailable. We propose a three-stage framework that leverages acoustic and phonological supervision during training while requiring only the rtMRI image at inference: phonological representations are converted into spatial bounding-box priors for articulator localization, visual and acoustic encoders are aligned via dual-level cross-modal contrastive pretraining, and the learned representations are fused through a cross-attention decoder, effectively transferring multimodal knowledge into a single-modality inference pipeline. Evaluated on 75-Speaker~Annot-16 and USC-TIMIT datasets, our method outperforms existing unimodal and multimodal methods, demonstrating that multimodal supervision provides transferable benefits for precise and clinically deployable vocal tract segmentation.
Daiqi Liu, Lukas Mulzer, Md Hasan +11
Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany · Smart Imaging Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany · Harvard Medical School / Massachusetts General Hospital, Boston, USA +3