Organizations: Department of Ecology and Conservation Biology, Texas A&M University, College Station, Texas, USA · Department of Computer Science, Rice University, Houston, Texas, USA · Department of Computer Science and Technology, University of Cambridge, Cambridge, England, UK · Department of Civil & Environmental Engineering, Texas A&M University, College Station, Texas, USA
Mapping the damage to buildings following natural and human-caused disasters is essential for disaster response and humanitarian assistance. However, differences in hazard types, geographic environments, building characteristics, and imaging conditions cause cross-event distribution shifts that limit the generalization of deep learning models to new disaster events, even for geospatial foundation models (GFMs) pretrained on extensive Earth observation data. Unsupervised domain adaptation (UDA) can mitigate these shifts, but adaptation remains challenging when damage-proportion and damage-appearance shifts coexist and interact. We identify enhancing target-domain discriminability as key to addressing this challenge. To this end, inspired by positive-unlabeled (PU) learning, we introduce positive-unlabeled domain adaptation, a paradigm that incorporates PU weak supervision to enhance target-domain discriminability, requiring only a few labeled damaged buildings in the target domain. Building upon this straightforward intuition, we develop Positive-ANchored Domain Adaptation (PANDA), comprising two complementary and mutually reinforcing components: Pairwise Alignment with Intra-class Robustness (PAIR) for discriminative representation learning and Refine Gate and Verifier (RAV) for supervision refinement. On a global-scale multi-disaster benchmark, PANDA generally outperforms representative domain adaptation and PU learning methods. Results on the 2025 Los Angeles wildfires show its effectiveness in new disaster scenarios with few labeled damaged buildings. Further experiments demonstrate the potential of integrating PANDA with GFMs for cross-event adaptation. These findings highlight PANDA's practical potential for rapid, reliable, and cross-event building damage mapping.
Figures & tables
Figure 1: Coupled distribution shifts across disaster events in building damage mapping: (a) different building damage patterns across disaster events (damage-appearance shift), and (b) varying proportions of damaged buildings across events (damage-proportion shift).
Figure 2: Comparison of PU learning, unsupervised domain adaptation and positive-unlabeled domain adaptation. For each paradigm, the left result shows the predicted building damage map, while the right result shows the ground-truth building damage map. Green and red denote undamaged and damaged buildings, respectively. ChatGPT (OpenAI, GPT-6.1 Sol) was used to generate the panda illustrations and the icons depicting damaged and undamaged buildings.
Figure 3: Benchmark and local study areas for cross-event building damage mapping: (a) spatial distribution of all disaster events considered in this study; (b) local study area of the 2025 Eaton Fire; and (c) local study area of the 2025 Palisades Fire.
Figure 4: Overview of the proposed PANDA framework, consisting of supervised source-domain pretraining and positive-unlabeled target-domain adaptation, in which PAIR and RAV jointly achieve cross-domain adaptation.
Method
Tornado
Volcano
Wildfire
OA
F1
OA
F1
OA
F1
Source-only
70.62±5.03
38.57±2.55
78.14±4.37
30.41±21.80
67.68±10.00
41.29±2.13
source-free UDA methods
SHOT
90.86±0.53
87.37±0.58
72.95±2.31
54.01±2.01
91.77±2.45
84.72±3.90
TPDS
48.24±16.85
43.04±11.70
90.60±1.84
75.90±3.42
38.57±10.44
24.30±13.30
DCPL
91.47±0.45
88.15±0.56
86.67±1.29
67.20±1.45
92.48±0.75
85.44±1.12
Table 1: Quantitative comparison of different methods on the target-domain disaster events.
Figure 5: Visualization comparison of building damage mapping results on the target disaster events. Red and green indicate damaged and undamaged buildings, respectively.
PAIR
RAV
Volcano
Tornado
OA
F1
OA
F1
✓
–
66.07±1.89
49.33±1.52
69.64±4.04
68.50±2.79
–
✓
88.74±4.08
73.91±7.30
95.26±1.12
90.98±1.34
✓
✓
93.57±0.91
82.62±2.32
94.65±0.60
91.68±1.13
Table 2: Ablation study of the PAIR and RAV modules.
PAIR
Volcano
Tornado
OA
F1
OA
F1
Lrs
91.48±2.84
78.89±5.35
94.63±0.63
90.95±1.07
Lrf
89.46±3.82
75.16±7.00
93.93±0.93
90.42±1.72
Lrw
93.57±0.91
82.62±2.32
94.65±0.60
91.68±1.13
Table 3: Comparison of different representation alignment strategies in PAIR.
Verifier
Refine Gate
Volcano
Tornado
OA
F1
OA
F1
–
✓
52.13±2.84
40.68±1.40
40.03±12.13
52.73±5.35
✓
–
92.62±1.23
78.76±3.42
81.87±2.55
62.53±7.28
✓
hi
62.24±4.22
46.58±2.69
90.98±1.31
87.77±1.45
✓
✓
93.57±0.91
82.62±2.32
94.65±0.60
91.68±1.13
Table 4: Ablation study of the components in RAV.
Method
Volcano
Tornado
OA
F1
OA
F1
GFM (Source)
86.12±0.50
54.44±2.45
88.71±1.05
79.94±2.29
GFM (CE)
88.42±1.23
55.79±7.47
67.04±0.05
0.28±0.32
GFM (PANDA)
92.46±3.56
81.08±6.83
92.55±0.92
89.37±0.98
Table 5: Performance of GFM-based methods for transferable building damage mapping.
Figure 6: t-SNE visualization of feature representations learned by the Source-only model and PANDA for the source and target Volcano datasets. Colors indicate different classes, while dark and light circles denote source- and target-domain samples, respectively.
Figure 7: t-SNE visualizations of representations learned by baseline methods and PANDA on the target Volcano dataset.
Figure 8: Hyperparameter analysis on the Tornado and Volcano datasets.
Method
Mask AP
Mask AP 75
SQ
SAMPolyBuild
25.79
21.30
75.09
FootprintSAM
28.03
28.76
77.23
Table 6: Comparison of building footprint extraction performance on the pooled test samples from all target-domain datasets.
Disaster Event
Building Localization
Building Damage Classification
Mask AP
Mask AP 75
OA
F1
Tornado
38.88
39.40
95.03±0.21
92.43±0.40
Volcano
33.75
31.97
84.80±0.52
61.04±1.49
Wildfire
32.55
28.26
96.38±0.31
92.10±0.90
Table 7: Performance of PANDA using automatically extracted building footprints.
Method
Eaton Fire
Palisades Fire
OA
F1
OA
F1
Source
85.72±0.01
0.47±0.78
34.98±0.05
0.09±0.16
Source + CE
86.85±0.53
14.87±6.57
36.08±0.33
3.43±1.00
DCPL
83.05±2.25
62.54±3.12
70.49±15.63
71.83±16.58
Supervised ( 1× )
90.84±0.64
52.92±5.06
51.95±4.96
41.11±9.32
Supervised ( 2× )
96.06±0.86
84.14±4.16
79.39±2.92
81.23±3.15
Table 8: Quantitative comparison on the local wildfire events.
Figure 9: Visualization of building damage mapping results for the Eaton Fire in Los Angeles. Pre-disaster scenario, post-disaster scenario, and mapping results are shown from left to right, with three zones of interest (A–C) highlighted for detailed visualization. Red and green indicate damaged and undamaged buildings, respectively.
Figure 10: Visualization of building damage mapping results for the Palisades Fire in Los Angeles. Pre-disaster scenario, post-disaster scenario, and mapping results are shown from left to right, with three zones of interest (A–C) highlighted for detailed visualization. Red and green indicate damaged and undamaged buildings, respectively.
Figure 11: Sensitivity of PANDA to the number of positive samples P on (a) Eaton Fire and (b) Palisades Fire. Shaded regions denote the standard deviation across different runs.
Department of Ecology and Conservation Biology, Texas A&M University, College Station, 77843, Texas, USA · Department of Computer Science, Stanford University, Stanford, 94305, CA, USA · Department of Mechanical Engineering, National University of Singapore, Singapore, 117575, Singapore