UPP-Gauss: Ultrasound Propagation Physics-informed Gaussian Splatting for B-mode Novel-View Synthesis
Authors: Guil Jung, Seok-Hwan Oh, Myeong-Gee Kim, Young-Min Kim, Hyeon-Jik Lee, Sang-Yun Kim, Hyeok-Jun Kwon, Hyuk-Sool Kwon, Hyeon-Min Bae
Organizations: Barreleye Inc., Seoul, South Korea · Department of Electrical Engineering, KAIST, Daejeon, South Korea · Department of Emergency Medicine, SNUBH, Seongnam, South Korea
Accurate novel-view synthesis of B-mode ultrasound images requires modeling acoustic propagation through tissue and the resulting appearance variations across probe poses. We propose Ultrasound Propagation Physics-informed Gaussian Splatting (UPP-Gauss), which integrates these acoustic interactions into an explicit Gaussian representation. UPP-Gauss constructs acoustic maps by sampling three 3D Gaussian fields using the probe pose and acoustic beam propagation direction, then combines these maps according to ultrasound propagation to synthesize B-mode images. Across three acoustically diverse datasets, UPP-Gauss achieves the best reconstruction quality with efficient rendering, improving PSNR over the best baseline on each dataset by 1.43 dB on average. These results demonstrate accurate and efficient B-mode novel-view synthesis through explicit Gaussian modeling of ultrasound propagation.
Figures & tables
Figure 1: Overview of UPP-Gauss. The scattering, reflection, and attenuation Gaussian fields are sampled on the probe imaging plane and combined through local echo formation and depth-wise transmission to synthesize a B-mode image.
Figure 2: Qualitative comparison on spine, porcine muscle, and thyroid. Error maps show absolute errors.
Method
PSNR ↑
SSIM ↑
GMS ↑
GMSD ↓
Spine Phantom
Re-sliced Median
25.18±2.97
0.8959±0.0557
0.9512±0.0276
0.1429±0.0513
ImplicitVol
23.65±3.13
0.9134±0.0386
0.9484±0.0262
0.1665±0.0538
Ultra-NeRF
25.80±0.86
0.8419±0.0305
0.9640±0.0104
0.1154±0.0182
UltraGS
22.90±1.91
0.7371±0.0607
0.9182±0.0334
0.1787±0.0408
UltraG-Ray
27.34±2.13
0.8316±0.0285
0.9669±0.0152
0.1105±0.0327
Table 1: Quantitative reconstruction comparison. Results are reported as mean ± standard deviation across test frames.
Method
Params (M)
Latency (ms/frame)
GFLOPs
Re-sliced Median
–
0.54
–
ImplicitVol
0.157
4.61
15.70
Ultra-NeRF
0.132
8.98
13.20
UltraGS
3.916
2.42
0.67
UltraG-Ray
1.767
2.50
0.91
UPP-Gauss
4.160
1.49
0.33
Table 2: Comparison of model complexity and rendering cost.
Figure 3: Qualitative acoustic-map ablation on porcine muscle.
Composition
Spine phantom
Porcine muscle
Thyroid
MS
28.33/0.8482
26.63/0.7115
22.85/0.6285
TR(MS+MR)
28.33/0.8552
26.64/0.7173
22.88/0.6620
TAMS
29.00/0.9234
26.67/0.7120
23.58/0.6569
TATR(MS+MR)
29.47/0.9411
26.99/0.7306
24.07/0.6825
Table 3: Ablation study of acoustic map combinations. Results are reported as PSNR/SSIM.
Ultrasound imaging uses sound waves to visualize anatomy and function, with AI improving image reconstruction, diagnosis, measurement, and scan guidance.
Novel view synthesis (NVS) in ultrasound has gained attention as a technique for generating anatomically plausible views beyond the acquired frames, offering new capabilities for training clinicians or data augmentation. However, current methods struggle with complex tissue and view-dependent acoustic effects. Physics-based NVS aims to address these limitations by including the ultrasound image formation process into the simulation. Recent approaches combine a learnable implicit scene representation with an ultrasound-specific rendering module, yet a substantial gap between simulation and reality remains. In this work, we introduce UltraG-Ray, a novel ultrasound scene representation based on a learnable 3D Gaussian field, coupled to an efficient physics-based module for B-mode synthesis. We explicitly encode ultrasound-specific parameters, such as attenuation and reflection, into a Gaussian-based spatial representation and realize image synthesis within a novel ray casting scheme. In contrast to previous methods, this approach naturally captures view-dependent attenuation effects, thereby enabling the generation of physically informed B-mode images with increased realism. We compare our method to state-of-the-art and observe consistent gains in image quality metrics (up to 15% increase on MS-SSIM), demonstrating clear improvement in terms of realism of the synthesized ultrasound images.
Felix Duelmer, Jakob Klaushofer, Magdalena Wysocki +2
Chair for Computer Aided Medical Procedures (CAMP), Technical University of Munich, Germany · Munich Center for Machine Learning (MCML), Munich, Germany
We present UltraVoxelGS, a 3D ultrasound reconstruction method that achieves both fast reconstruction and physically faithful rendering for the first time, bringing live spatial feedback during 2D ultrasound scanning within reach. This is made possible by a feed-forward design that predicts a complete Gaussian scene representation from posed ultrasound images directly, entirely bypassing the per-scene optimization bottleneck that has confined prior methods to offline use. Realising such feed-forward prediction in this setting is non-trivial: unlike natural images, ultrasound slices share at most one-dimensional intersections and exhibit view-dependent appearance due to acoustic propagation and attenuation, violating the dense overlap and photometric consistency assumed by existing feed-forward Gaussian methods. Hence, to achieve fast reconstruction, we introduce a feed-forward voxel-to-Gaussian pass that decouples representation size from input count by lifting all posed slices into a fixed-size voxel support and predicting Gaussian parameters directly. For faithful rendering, we propose ultrasound-aware appearance rendering strategy factorize reflection from cumulative attenuation during training and exploit appearance continuity among spatially adjacent slices for efficient Render-time Appearance Adaptation. On both real-world and simulated datasets, UltraVoxelGS achieves best PSNR/SSIM compared with per-scene optimization baselines while reducing inference from 10-20 minutes to approximately 10 seconds (over 35 times faster) and scales to sequences exceeding 1,000 frames. Code is available at https://github.com/YuebyYue/UltraVoxelGS-camera-ready.
Yue Wang, Haoxin Chen, Xiaoqing Guo
Department of Computer Science, Hong Kong Baptist University, Hong Kong SAR, China
Wide Field-of-View (WFoV) reconstruction enhances 3D ultrasound imaging by providing valuable anatomical context for segmentation models and visualization. Clinical ultrasound volumes are predominantly acquired using convex probes, which generate expanding, diverging acoustic beams to maximize anatomical coverage. Stitching these sweeps together traditionally introduces significant compounding artifacts and aliasing due to depth-dependent resolution changes. Here, we introduce Ultra-Wide-NeRF, a Multivariate 3D Gaussian (MVG) NeRF-based method for WFoV ultrasound reconstruction. By explicitly modeling the complex beam geometry using distance-dependent convex volumetric sampling and anisotropic 3D Gaussians, our method inherently mitigates these compounding artifacts and provides anti-aliasing. Beyond simply reconstructing a static 3D grid, our NeRF-based approach yields a continuous neural representation of the tissue, enabling the synthesis of high-fidelity novel views from arbitrary virtual trajectories. We validate Ultra-Wide-NeRF for intracardiac echocardiography on phantom and porcine datasets, demonstrating that our method expands the spatial context important in intraoperative navigation. Code will be open-sourced upon publication.
Patris Valera, Magdalena Wysocki, Felix Duelmer +4
Chair for Computer Aided Medical Procedures (CAMP), Technical University of Munich, Germany · Munich Center for Machine Learning (MCML), Munich, Germany · LUMA Vision, Beech Hill Road, Dublin, Ireland