Organizations: Division of Radiology, Department for Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden. · Artificial Intelligence and Translational Imaging (ATI) Lab, Department of Radiology, School of Medicine, University of Crete, Heraklion, Crete, Greece. · Department of Nuclear Medicine and Medical Physics, Section Nuclear Medicine Huddinge, Karolinska University Hospital, Stockholm, Sweden. · Department of Nuclear Medicine and Medical Physics, Theranostics Trial Center, Karolinska University Hospital, Stockholm, Sweden.

Abstract

Large collections of three-dimensional radiation dose maps linked to patient anatomy are needed to develop artificial intelligence (AI) models for personalized internal dosimetry in nuclear medicine, but access to such data remains limited. Here we present DosePET, an open-source dataset of 2,100 patient-specific absorbed-dose maps generated by Monte Carlo simulation of publicly available PET/CT examinations: 1,503 [18F]FDG examinations from ENHANCE.PET and 369 [18F]PSMA-1007 and 228 [68Ga]Ga-PSMA-11 examinations from PSMA-PET-CT-Lesions, acquired at five institutions with seven scanner models. For each examination, the CT was resampled to the native PET grid to build a voxelized patient phantom, the quantitative PET image defined the radionuclide source, and radiation transport was simulated with GATE version 9.4. Organ and tissue masks were generated from the CT with TotalSegmentator. Each study folder contains a NIfTI dose map integrated from scan time to infinity, 117 binary organ/tissue masks, a report of regional dosimetric quantities, including mean absorbed doses, dose conversion factors and scan-time dose rates, and simulation metadata. The total processing time was 1,542.4 hours. Python tools support selective downloading and conversion to scan-time dose-rate or dose-per-decay maps, and an agent skill guides pairing with the source PET/CT images. DosePET is publicly available at https://huggingface.co/datasets/eltzanis/DosePET.

Figures & tables

Explore similar work

Apr 7, 2026

DosimeTron: Automating Personalized Monte Carlo Radiation Dosimetry in PET/CT with Agentic AI

Purpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations. Materials and Methods: In this retrospective study, DosimeTron was evaluated on a publicly available PSMA-PET/CT dataset comprising 597 studies from 378 male patients acquired on three scanner models (18-F, n = 369; 68-Ga, n = 228). The system uses GPT-5.2 as its reasoning engine and 23 tools exposed via four Model Context Protocol servers, automating DICOM metadata extraction, image preprocessing, MC simulation, organ segmentation, and dosimetric reporting through natural-language interaction. Agentic performance was assessed using diverse prompt templates spanning single-turn instructions of varying specificity and multi-turn conversational exchanges, monitored via OpenTelemetry traces. Dosimetric accuracy was validated against OpenDose3D across 114 cases and 22 organs using Pearson's r, Lin's concordance correlation coefficient (CCC), and Bland-Altman analysis. Results: Across all prompt templates and all runs, no execution failures, pipeline errors, or hallucinated outputs were observed. Pearson's r ranged from 0.965 to 1.000 (median 0.997; all p < 0.001) and CCC from 0.963 to 1.000 (median 0.996). Mean absolute percentage difference was below 5% for 19 of 22 organs (median 2.5%). Total per-study processing time (SD) was 32.3 (6.0) minutes. Conclusion: DosimeTron autonomously executed complex dosimetry pipelines across diverse prompt configurations and achieved high dosimetric agreement with OpenDose3D at clinically acceptable processing times, demonstrating the feasibility of agentic AI for patient-specific Monte Carlo dosimetry in PET/CT.
Apr 14, 2026

DoseRAD2026 Challenge dataset: AI accelerated photon and proton dose calculation for radiotherapy

Purpose: Accurate dose calculation is essential in radiotherapy for precise tumor irradiation while sparing healthy tissue. With the growing adoption of MRI-guided and real-time adaptive radiotherapy, fast and accurate dose calculation on CT and MRI is increasingly needed. The DoseRAD2026 dataset and challenge provide a public benchmark of paired CT and MRI data with beam-level photon and proton Monte Carlo dose distributions for developing and evaluating advanced dose calculation methods. Acquisition and validation methods: The dataset comprises paired CT and MRI from 115 patients (75 training, 40 testing) treated on an MRI-linac for thoracic or abdominal lesions, derived from the SynthRAD2025 dataset. Pre-processing included deformable image registration, air-cavity correction, and resampling. Ground-truth photon (6 MV) and proton dose distributions were computed using open-source Monte Carlo algorithms, yielding 40,500 photon beams and 81,000 proton beamlets. Data format and usage notes: Data are organized into photon and proton subsets with paired CT-MRI images, beam-level dose distributions, and JSON beam configuration files. Files are provided in compressed MetaImage (.mha) format. The dataset is released under CC BY-NC 4.0, with training data available from April 2026 and the test set withheld until March 2030. Potential applications: The dataset supports benchmarking of fast dose calculation methods, including beam-level dose estimation for photon and proton therapy, MRI-based dose calculation in MRI-guided workflows, and real-time adaptive radiotherapy.
May 20, 2026

An Open Multi-Center Whole-Body FDG PET/CT Foundation Model for Tumor Segmentation

The synergistic interpretation of anatomical information from computed tomography (CT) and metabolic information from positron emission tomography (PET) is important to oncologic imaging. However, existing deep learning methods for PET/CT remain largely task-specific, are often trained on single-center cohorts, or adopt dual-branch fusion schemes that delay cross-modal interaction and underutilize early spatial correspondence between PET and CT. To address these limitations, we present an open-source, multi-center, whole-body FDG PET/CT foundation model utilizing 4,997 harmonized scans from four public datasets. Our framework employs hierarchical UNet-shaped backbones with early channel-wise concatenation, enabling anatomical and metabolic features to interact from the first embedding layer onward. We further introduce a masked autoencoding objective based on zero-mean imputation, combined with a weighted global reconstruction loss. This design avoids non-physical intensity discontinuities at masked-region boundaries that arise from learnable mask tokens. On downstream AutoPET lesion segmentation, the proposed models demonstrate strong label efficiency: with only 10% of the labeled training data, they achieve performance comparable to models trained from scratch on the full dataset. Under extreme 5-shot linear probing, joint PET/CT pretraining also achieves higher Dice scores than separated-modality pretraining. This multi-center foundation model demonstrates label efficiency and cross-modality representation learning for PET/CT tumor segmentation. It provides a robust, open-source basis for advancing automated oncologic imaging, significantly reducing the need for large-scale manual annotations in clinical practice.