physics.med-phApr 7, 2026

DosimeTron: Automating Personalized Monte Carlo Radiation Dosimetry in PET/CT with Agentic AI

Authors: Eleftherios Tzanis, Michail E. Klontzas, Antonios Tzortzakakis

Organizations: Division of Radiology, Department for Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden · Artificial Intelligence and Translational Imaging (ATI) Lab, Department of Radiology, School of Medicine, University of Crete, Heraklion, Crete, Greece · Computational Biomedicine Laboratory, Institute of Computer Science Foundation for Research and Technology Hellas (ICS - FORTH), Heraklion, Crete, Greece · Department of Nuclear Medicine and Medical Physics, Section Nuclear Medicine Huddinge, Karolinska University Hospital, Stockholm, Sweden · 

Abstract

Purpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations. Materials and Methods: In this retrospective study, DosimeTron was evaluated on a publicly available PSMA-PET/CT dataset comprising 597 studies from 378 male patients acquired on three scanner models (18-F, n = 369; 68-Ga, n = 228). The system uses GPT-5.2 as its reasoning engine and 23 tools exposed via four Model Context Protocol servers, automating DICOM metadata extraction, image preprocessing, MC simulation, organ segmentation, and dosimetric reporting through natural-language interaction. Agentic performance was assessed using diverse prompt templates spanning single-turn instructions of varying specificity and multi-turn conversational exchanges, monitored via OpenTelemetry traces. Dosimetric accuracy was validated against OpenDose3D across 114 cases and 22 organs using Pearson's r, Lin's concordance correlation coefficient (CCC), and Bland-Altman analysis. Results: Across all prompt templates and all runs, no execution failures, pipeline errors, or hallucinated outputs were observed. Pearson's r ranged from 0.965 to 1.000 (median 0.997; all p < 0.001) and CCC from 0.963 to 1.000 (median 0.996). Mean absolute percentage difference was below 5% for 19 of 22 organs (median 2.5%). Total per-study processing time (SD) was 32.3 (6.0) minutes. Conclusion: DosimeTron autonomously executed complex dosimetry pipelines across diverse prompt configurations and achieved high dosimetric agreement with OpenDose3D at clinically acceptable processing times, demonstrating the feasibility of agentic AI for patient-specific Monte Carlo dosimetry in PET/CT.

Explore similar work

May 7, 2026

The autoPET3 Challenge: Automated Lesion Segmentation in Whole-Body PET/CT \unicodex2013\unicode{x2013} Multitracer Multicenter Generalization

We report the design and results of the third autoPET challenge (MICCAI 2024), which benchmarked automated lesion segmentation in whole-body PET/CT under a compositional generalization setting. Training data comprised 1,014 [18F]-FDG PET/CT studies from the University Hospital Tübingen and 597 [18F]/[68Ga]-PSMA PET/CT studies from the LMU University Hospital Munich, constituting the largest publicly available annotated PSMA PET/CT dataset to date. The held-out test set of 200 studies covered four tracer-center combinations, two of which represented unseen compositional pairings. A complementary data-centric award category isolated the contribution of data handling strategies by restricting participants to a fixed baseline model. Seventeen teams submitted 27 algorithms, predominantly nnU-Net-based 3D networks with PET/CT channel concatenation. The top-ranked algorithm achieved a mean DSC of 0.66, FNV of 3.18 mL, and FPV of 2.78 mL across all four test conditions, improving DSC by 8% and reducing the false-negative volume by 5 mL relative to the provided baseline. Ranking was stable across bootstrap resampling and alternative ranking schemes for the top tier. Beyond the benchmark, we provide an in-depth analysis of segmentation performance at the patient and lesion level. Three main conclusions can be drawn: (1) in-domain multitracer PET/CT segmentation is sufficient and probably approaching reader agreement; (2) compositional generalization to unseen tracer-center combinations remains an open problem mainly driven by systematic volume overestimation; (3) heterogeneity and case difficulty drive performance variation substantially more than the choice of algorithm among top-ranked teams.
Mar 14, 2026

TheraAgent: Multi-Agent Framework with Self-Evolving Memory and Evidence-Calibrated Reasoning for PET Theranostics

PET theranostics is transforming precision oncology, yet treatment response varies substantially; many patients receiving 177Lu-PSMA radioligand therapy (RLT) for metastatic castration-resistant prostate cancer (mCRPC) fail to respond, demanding reliable pre-therapy prediction. While LLM-based agents have shown remarkable potential in complex medical diagnosis, their application to PET theranostic outcome prediction remains unexplored, which faces three key challenges: (1) data and knowledge scarcity: RLT was only FDA-approved in 2022, yielding few training cases and insufficient domain knowledge in general LLMs; (2) heterogeneous information integration: robust prediction hinges on structured knowledge extraction from PET/CT, laboratory tests, and free-text clinical documentation; (3) evidence-grounded reasoning: clinical decisions must be anchored in trial evidence rather than LLM hallucinations. In this paper, we present TheraAgent, to our knowledge, the first agentic framework for PET theranostics, with three core innovations: (1) Multi-Expert Feature Extraction with Confidence-Weighted Consensus, where three specialized experts process heterogeneous inputs with uncertainty quantification; (2) Self-Evolving Agentic Memory (SEA-Mem), which learns prognostic patterns from accumulated cases, enabling case-based reasoning from limited data; (3) Evidence-Calibrated Reasoning, integrating a curated theranostics knowledge base to ground predictions in VISION/TheraP trial evidence. Evaluated on 35 real patients and 400 synthetic cases, TheraAgent achieves 75.7% overall accuracy on real patients and 87.0% on synthetic cases, outperforming MDAgents and MedAgent-Pro by over 20%. These results highlight a promising blueprint for trustworthy AI agents in PET theranostics, enabling trial-calibrated, multi-source decision support. Code will be released upon acceptance.
Apr 16, 2026

RadAgent: A tool-using AI agent for stepwise interpretation of chest computed tomography

Vision-language models (VLM) have markedly advanced AI-driven interpretation and reporting of complex medical imaging, such as computed tomography (CT). Yet, existing methods largely relegate clinicians to passive observers of final outputs, offering no interpretable reasoning trace for them to inspect, validate, or refine. To address this, we introduce RadAgent, a tool-using AI agent that generates CT reports through a stepwise and interpretable process. Each resulting report is accompanied by a fully inspectable trace of intermediate decisions and tool interactions, allowing clinicians to examine how the reported findings are derived. In our experiments, we observe that RadAgent improves chest CT report generation over its 3D VLM counterpart, CT-Chat, across three dimensions. Clinical accuracy improves by 5.8 points (35.4% relative) in macro-F1 and 5.1 points (18.6% relative) in micro-F1. Robustness under adversarial conditions improves by 24.7 points (41.9% relative). Furthermore, RadAgent achieves 37.0% in faithfulness, a new capability entirely absent in its 3D VLM counterpart. By structuring the interpretation of chest CT as an explicit, tool-augmented and iterative reasoning trace, RadAgent brings us closer toward transparent and reliable AI for radiology.