Overview

Camera calibration estimates intrinsics such as focal length and distortion, and extrinsics such as camera pose relative to other cameras, robots, or sensors. Approaches range from target-based geometric optimization and bundle adjustment to target-free self-calibration, learned correspondence or parameter prediction, and refinements using motion, scene geometry, or external maps. Work spans single cameras, multi-camera rigs, and camera–LiDAR, radar, event-camera, and robot systems, with benchmarks testing reprojection, pose, reconstruction, and downstream task accuracy. A central tension is that low reprojection error does not always mean accurate 3D results, while robustness depends on informative observations, parameter observability, changing conditions, and reliable independent verification.

Latest papers

65 papers10 papers in the last four weeks, up 43% on the four weeks before. 0.1% of all new papers.

Feb 28, 2026

Geometry OR Tracker: Universal Geometric Operating Room Tracking

In operating rooms (OR), world-scale multi-view 3D tracking supports downstream applications such as surgeon behavior recognition, where physically meaningful quantities such as distances and motion statistics must be measured in meters. However, real clinical deployments rarely satisfy the geometric prerequisites for stable multi-view fusion and tracking: camera calibration and RGB-D registration are always unreliable, leading to cross-view geometric inconsistency that produces "ghosting" during fusion and degrades 3D trajectories in a shared OR coordinate frame. To address this, we introduce Geometry OR Tracker, a two-stage pipeline that first rectifies imprecise calibration into a scaleconsistent and geometrically consistent camera setup with a single global scale via a Multi-view Metric Geometry Rectification module, and then performs Occlusion-Robust 3D Point Tracking directly in the unified OR world frame. On the MM-OR benchmark, improved geometric consistency translates into tracking gains: our rectification front-end reduces cross-view depth disagreement by more than 30×\times compared to raw calibration. Ablation studies further demonstrate the relationship between calibration quality and tracking accuracy, showing that improved geometric consistency yields stronger world-frame tracking.
Feb 18, 2026

SCAR: Satellite Imagery-Based Calibration for Aerial Recordings

We introduce SCAR, a method for long-term auto-calibration refinement of aerial visual-inertial systems that exploits georeferenced satellite imagery as a persistent global reference. SCAR estimates both intrinsic and extrinsic parameters by aligning aerial images with 2D--3D correspondences derived from publicly available orthophotos and elevation models. In contrast to existing approaches that rely on dedicated calibration maneuvers or manually surveyed ground control points, our method leverages external geospatial data to detect and correct calibration degradation under field deployment conditions. We evaluate our approach on six large-scale aerial campaigns conducted over two years under diverse seasonal and environmental conditions. Across all sequences, SCAR consistently outperforms established baselines (Kalibr, COLMAP, VINS-Mono), reducing median reprojection error by a large margin, and translating these calibration gains into substantially lower visual localization rotation errors and higher pose accuracy. These results demonstrate that SCAR provides accurate, robust, and reproducible calibration over long-term aerial operations without the need for manual intervention.
Nov 6, 2025

A Linear Fractional Transformation Model and Calibration Method for Light Field Camera

Accurate intrinsic calibration is a crucial yet challenging prerequisite for 3D reconstruction using light field cameras. Existing calibration models typically analyze the main lens and micro lens array (MLA) in a coupled manner, resulting in high complexity and a large number of parameters. In this paper, we propose a linear fractional transformation (LFT) model that introduces a single parameter αα to decouple the imaging processes of the main lens and the MLA. A dedicated matrix Hα\mathbf{H}_α is designed to characterize the MLA projection, enabling the main lens and the MLA to be calibrated independently. The proposed calibration method consists of an analytical least-squares solution for Hα\mathbf{H}_α, followed by joint nonlinear refinement of all intrinsic parameters. Experimental results on both physical datasets and simulated data demonstrate that the proposed method achieves a mean translation error of 2.1%2.1\%, outperforming the state-of-the-art, while maintaining sub-pixel reprojection accuracy. The complete codebase, including a light field simulator based on the proposed model, is openly available to the research community.
Oct 28, 2025

Kineo: Calibration-Free Metric Motion Capture From Sparse RGB Cameras

Markerless multi-view motion capture is often constrained by the need for precise camera calibration, limiting accessibility for non-experts and in-the-wild captures. Existing calibration-free approaches mitigate this requirement but suffer from high computational cost and reduced reconstruction accuracy. We present Kineo, a fully automatic, calibration-free pipeline for markerless motion capture from videos captured by unsynchronized, uncalibrated, consumer-grade RGB cameras. Kineo leverages 2D keypoints from off-the-shelf detectors to simultaneously calibrate cameras, including Brown-Conrady distortion coefficients, and reconstruct 3D keypoints and dense scene pointmaps at metric scale. A confidence-aware spatio-temporal keypoint subsampling strategy, combined with graph-based global optimization, enables robust calibration at a fixed computational cost independent of sequence length. We further introduce a pairwise reprojection consistency score, a heuristic measure of the agreement between views, which we use to weight bone lengths in metric scale recovery. Evaluations on EgoHumans and Human3.6M demonstrate substantial improvements over prior calibration-free methods. Compared to previous state-of-the-art approaches, Kineo reduces camera translation error by approximately 83-85%, camera angular error by 86-92%, and world mean-per-joint position error (W-MPJPE) by 83-91%. Kineo is also efficient in real-world scenarios, processing multi-view sequences faster than their duration in a specific configuration (e.g., 36 min to process 1 h 23 min of footage). The full pipeline and evaluation code are openly released to promote reproducibility and practical adoption at: https://liris-xr.github.io/kineo/