cs.ROFeb 16, 2026

Real-time Monocular 2D and 3D Perception of Endoluminal Scenes for Controlling Flexible Robotic Endoscopic Instruments

Authors: Ruofeng Wei, Kai Chen, Yui Lun Ng, Yiyao Ma, Justin Di-Lang Ho, Hon Sing Tong, Xiaomei Wang, Jing Dai, +2 more

Organizations: Department of Computer Science and Engineering, The Chinese University of Hong Kong, Hong Kong, China. · Department of Mechanical Engineering, The University of Hong Kong, China. · Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, and also with the Department of Mechanical Engineering, The University of Hong Kong.

Abstract

Endoluminal surgery offers a minimally invasive option for early-stage gastrointestinal and urinary tract cancers but is limited by surgical tools and a steep learning curve. Robotic systems, particularly continuum robots, provide flexible instruments that enable precise tissue resection, potentially improving outcomes. This paper presents a visual perception platform for a continuum robotic system in endoluminal surgery. Our goal is to utilize monocular endoscopic image-based perception algorithms to identify position and orientation of flexible instruments and measure their distances from tissues. We introduce 2D and 3D learning-based perception algorithms and develop a physically-realistic simulator that models flexible instruments dynamics. This simulator generates realistic endoluminal scenes, enabling control of flexible robots and substantial data collection. Using a continuum robot prototype, we conducted module and system-level evaluations. Results show that our algorithms improve control of flexible instruments, reducing manipulation time by over 70% for trajectory-following tasks and enhancing understanding of surgical scenarios, leading to robust endoluminal surgeries.

Figures & tables

Explore similar work

Aug 13, 2026

Capstan-driven Continuum Surgical Robot: Design, Modeling, and Perception

Shape and force sensing have long been critical bottlenecks in the development of compact capstan-driven continuum surgical robots, primarily due to the difficulty of obtaining cable tension information within the confined capstan assembly. To overcome these challenges, this paper presents an integrated design-modeling-sensing approach based on the concept of actuation-perception co-design. A compliant element is introduced into the motor mounting bracket of the drive system, enabling micro-deformation under the cable reaction force and thereby allowing real-time cable tension measurement without occupying the compact capstan space. To address the modeling complexity arising from unconventional joint configurations introduced by the spatial cable routing strategy, a parallel computation framework based on a multibody short-thick-beam model is proposed, which captures shear effects in short beam segments and synergistic multi-cable interactions while achieving real-time performance. Building on this framework, stable shape and force sensing is achieved by incorporating a proximal multi-axis force/torque sensor as an additional measurement anchor. Following this design-modeling-sensing framework, capstan-driven continuum surgical robots with single- and dual-segment configurations are developed. Experimental results validate the proposed framework in both single- and dual-segment continuum robots, demonstrating real-time tip pose estimation together with contact force and location perception. By enabling cable tension feedback without compromising the compact capstan architecture, the proposed framework makes integrated perception feasible for capstan-driven continuum surgical robots.
Feb 18, 2026

MarUco: A Markerless 6D Pose Estimation Framework for Closed-Loop Control of Surgical Continuum Manipulators

Flexible endoscopic continuum manipulators offer high dexterity and access to complex anatomy, but nonlinear hysteresis limits feedforward control accuracy. Closed-loop control can compensate for these errors but requires accurate six-degree-of-freedom (6D) end-effector pose feedback. We present MarUco, a markerless 6D pose estimation framework for closed-loop control using only stereo vision during operation. A photorealistic pseudo-rigid-body simulation pipeline generates large-scale annotated training data without manual labeling. A multifeature fusion network integrates masks, keypoints, heatmaps, and bounding boxes from both stereo views to estimate an initial pose, followed by a learned single-pass render-and-compare module that refines the pose without iterative optimization. Kinematics-free hand-eye calibration estimates camera-to-robot-base extrinsics, and self-supervised adaptation uses unlabeled real stereo pairs to mitigate sim-to-real pose error. Across 1,000 real samples, MarUco achieves translation and rotation errors of 0.78 ±\pm 0.50 mm and 3.07 ±\pm 1.25°, respectively, with a total processing time of 52.4 ms per stereo pair. In closed-loop experiments over eight reference paths, MarUco achieves a mean terminal translation error of 1.8 mm, an 88% reduction relative to uncompensated open-loop control. To the best of our knowledge, this is the first markerless position-based visual servoing framework for continuum manipulators.
Sep 27, 2026

Contact-Adaptive Robotic Ultrasound Probe Control for Tissue Exploration and Continuous Task-Relevant Visualization Using Robot-Free Image-Motion Demonstration

Robotic ultrasound commonly targets standardized views, predefined scanning protocols, or expert-scan reproduction. We target a different role: while a clinician performs the primary procedure, a robotic assistant maintains a clinician-selected view so that changing tissue remains observable. We present contact-adaptive robotic ultrasound monitoring derived from robot-free demonstrations. Sonologger clamps a six-axis inertial sensor to the clinician-operated probe and records synchronized ultrasound and probe-frame relative rotations without a robot, camera, or tracker. Rather than imitating trajectories, the recordings measure which probe axis and sign the clinician uses to correct an image offset. A measured image latency is removed before still-move-still segmentation yields relative-rotation labels; translation is excluded from control because of inertial drift. These measurements parameterize the Demonstration-Informed Image-Motion Controller (DIMC), an interpretable, non-learned controller combined with beam-axis force regulation and an independent safety supervisor with 5 N forced retreat. On a dynamic bladder phantom, DIMC acquired and held a task-relevant view in 7 of 7 blind, pose-paired trials versus 1 of 7 for a static hold (McNemar p = 0.031), and retained the view during syringe-driven hydro-distension while the supervisor bounded the force excursion. The framework offers an operational representation of ultrasound context for contact-adaptive intraoperative monitoring; clinical validation remains future work.