cs.CVFeb 22, 2026

RetinaVision: XAI-Driven Augmented Regulation for Precise Retinal Disease Classification using deep learning framework

Authors: Mohammad Tahmid Noor, Shayan Abrar, Jannatul Adan Mahi, Md Parvez Mia, Asaduzzaman Hridoy, Samanta Ghosh

Organizations: Dept. of CSE East West University Dhaka, Bangladesh · Dept. of CSE American International University-Bangladesh Dhaka, Bangladesh · Dept. of ICT Bangladesh Army University of Engineering and Technology Dhaka, Bangladesh

Abstract

Early and accurate classification of retinal diseases is critical to counter vision loss and for guiding clinical management of retinal diseases. In this study, we proposed a deep learning method for retinal disease classification utilizing optical coherence tomography (OCT) images from the Retinal OCT Image Classification - C8 dataset (comprising 24,000 labeled images spanning eight conditions). Images were resized to 224x224 px and tested on convolutional neural network (CNN) architectures: Xception and InceptionV3. Data augmentation techniques (CutMix, MixUp) were employed to enhance model generalization. Additionally, we applied GradCAM and LIME for interpretability evaluation. We implemented this in a real-world scenario via our web application named RetinaVision. This study found that Xception was the most accurate network (95.25%), followed closely by InceptionV3 (94.82%). These results suggest that deep learning methods allow effective OCT retinal disease classification and highlight the importance of implementing accuracy and interpretability for clinical applications.

Explore similar work

Aug 18, 2026

RetiWave-Mamba: A Dual-Stream Network for Retinal Disease Detection based on Multi-scale Context and Feature-Adaptive Mamba Projection

Retinal diseases are a leading cause of irreversible vision impairment, making early and accurate diagnosis essential for effective treatment. Optical Coherence Tomography (OCT) serves as a critical imaging modality for this purpose, yet its automated analysis is hindered by inherent speckle noise, varying lesion scales, and subtle inter-class similarities. To address these challenges, we propose a novel framework, RetiWave-Mamba, which integrates spatial-frequency domain learning with state-of-the-art state space models. The framework utilizes Discrete Wavelet Transform (DWT) to decompose OCT images into low- and high-frequency streams, enabling decoupled processing of structural context and fine-grained details. For the low-frequency branch, we design a Multi-scale Contextual Localization Module (MCLM), which synergizes multi-scale dilation with spatial attention to expand the global receptive field and precisely localize lesion regions. For the high-frequency branch, we introduce an Attention-Guided High-Resolution Network (AG-HRNet) equipped with an intelligent gating mechanism to suppress noise propagation during multi-scale interactions. Furthermore, a Feature-Adaptive Mamba Projector (FAMP) is incorporated to form complementary channel-wise feature paths and adaptively reweight them using Mamba-generated gates. Extensive experiments on the OCT-C8 dataset demonstrate that our approach achieves a state-of-the-art (SOTA) classification accuracy of 98.38, surpassing existing methods. These results highlight the effectiveness of RetiWave-Mamba in identifying retinal pathologies and support its potential for computer-aided OCT image analysis.
Mar 24, 2026

Retinal Disease Classification from Fundus Images using CNN Transfer Learning

Retinal diseases remain among the leading preventable causes of visual impairment worldwide. Automated screening based on fundus image analysis has the potential to expand access to early detection, particularly in underserved populations. This paper presents a reproducible deep learning pipeline for binary retinal disease risk classification from publicly available fundus photographs. We implement and compare a baseline convolutional neural network with a transfer learning approach using a pretrained VGG16 backbone and evaluate generalization on held-out data. To address class imbalance, we apply class weighting and report standard classification metrics including accuracy, precision, recall, F1-score, confusion matrices, and ROC-AUC. The VGG16 transfer learning model achieves 90.8% test accuracy with a weighted F1-score of 0.90, substantially outperforming the baseline CNN (83.1% accuracy). Results indicate that transfer learning improves discrimination compared to a baseline CNN, while also revealing remaining challenges in sensitivity to minority disease cases. We discuss practical limitations related to dataset characteristics, class imbalance, and threshold selection, and provide guidance for reproducibility and future improvements for clinically reliable screening
Feb 23, 2025

Interpretable Retinal Disease Prediction Using Biology-Informed Heterogeneous Graph Representations

Interpretability is crucial for utilizing machine learning models as clinical decision support tools for medical diagnostics. However, most state-of-the-art image classifiers based on neural networks are not interpretable. As a result, clinicians often resort to known biomarkers to guide diagnosis, although biomarker-based classification often suffers from drastic information loss compared to raw medical images. This work proposes a method that preserves the rich imaging information while simultaneously enhancing the interpretability of predictions for diabetic retinopathy staging from optical coherence tomography angiography (OCTA) images. The core contribution of our method is a novel biology-informed heterogeneous graph representation that models retinal vessel segments, intercapillary areas, and the foveal avascular zone (FAZ) in a human-interpretable way. This graph representation allows us to frame diabetic retinopathy staging as a graph-level classification task, which we solve using an established, efficient graph neural network architecture. We compare our method against established methods, including classical biomarker-based classifiers, convolutional neural networks (CNNs), and vision transformers in predicting the clinically assigned DR stage based on color fundus photography images. We find stage agreement rates of our method and alternative vision model based classifiers saturating at AUC-ROC values of 84%. Crucially, we use our biology-informed graph to provide explanations of great detail. Our approach surpasses existing methods in precisely localizing and identifying abnormal vessels and non-perfusion areas. Our approach sets the stage for the interpretable identification of patients who require special attention due to their traceable microvascular changes, only observable using the details of OCTA images.