cs.NEFeb 16, 2026

Joint Sensor Deployment and Physics-Informed Graph Transformer for Smart Grid Attack Detection

Authors: Mariam Elnour, Mohammad AlShaikh Saleh, Rachad Atat, Xiang Huo, Abdulrahman Takiddin, Muhammad Ismail, Hasan Kurban, Katherine R. Davis, +1 more

Organizations: department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77840, USA · department of Electrical and Computer Engineering, Texas A&M University at Qatar, Doha, Qatar · department of Computer Science and Mathematics, Lebanese American University, Beirut 1102-2801, Lebanon · department of Electrical and Computer Engineering, Hampton University, 100 E Queen St, Hampton, VA 23669, USA · department of Electrical and Computer Engineering, FAMU-FSU College of Engineering, Florida State University, 2525 Pottsdamer Street. Tallahassee, FL 32310-6046, USA · Cybersecurity Education, Research, and Outreach Center (CEROC) and the department of Computer Science, Tennessee Tech University, Cookeville, TN, USA · College of Science and Engineering, Hamad Bin Khalifa University, Doha 34110, Qatar

Abstract

This paper proposes a joint multi-objective optimization framework for strategic sensor placement in power systems to enhance attack detection. A novel physics-informed graph transformer network (PIGTN)-based detection model is proposed. Non-dominated sorting genetic algorithm-II (NSGA-II) jointly optimizes sensor locations and the PIGTN's detection performance, while considering practical constraints. The combinatorial space of feasible sensor placements is explored using NSGA-II, while concurrently training the proposed detector in a closed-loop setting. Compared to baseline sensor placement methods, the proposed framework consistently demonstrates robustness under sensor failures and improvements in detection performance in seven benchmark cases, including the 14, 30, IEEE-30, 39, 57, 118 and the 200 bus systems. By incorporating AC power flow constraints, the proposed PIGTN-based detection model generalizes well to unseen attacks and outperforms other graph network-based variants (topology-aware models), achieving improvements up to 37% in accuracy and 73% in detection rate, with a mean false alarms rate of 0.3%. In addition, optimized sensor layouts significantly improve the performance of power system state estimation, achieving a 61%--98% reduction in the average state error.

Figures & tables

Explore similar work

CardsList
  1. Attack Detection using Time Series Foundation Models

    Jun 4, 2026Sribalaji C. Anand, Anh Tung Nguyen, George J. PappasCyber-Physical SystemsCybersecurity

  2. GenAI-FDIA: Physics-Informed Generative Models for False Data Injection Attacks

    May 15, 2026Mohammad A. Razzaque, Muta Tah HiraCyber-Physical SystemsPhysics-Informed Generative Modeling