M-Gaussian: An Magnetic Gaussian Framework for Efficient Multi-Stack MRI Reconstruction
Authors: Kangyuan Zheng, Xuan Cai, Jiangqi Wang, Guixing Fu, Zhuoshuo Li, Yazhou Chen, Xinting Ge, Liangqiong Qu, +1 more
Organizations: School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China. · the School of Information Science and Engineering, Shandong Normal University, Shandong, China. · School of Computing and Data Science, The University of Hong Kong, Hong Kong, China.
Magnetic Resonance Imaging (MRI) is a crucial non-invasive imaging modality. In routine clinical practice, multi-stack thick-slice acquisitions are widely used to reduce scan time and motion sensitivity, particularly in challenging scenarios such as fetal brain imaging. However, the resulting severe through-plane anisotropy compromises volumetric analysis and downstream quantitative assessment, necessitating robust reconstruction of isotropic high-resolution volumes. Implicit neural representation methods, while achieving high quality, suffer from computational inefficiency due to complex network structures. We present M-Gaussian, adapting 3D Gaussian Splatting to MRI reconstruction. Our contributions include: (1) Magnetic Gaussian primitives with physics-consistent volumetric rendering, (2) neural residual field for high-frequency detail refinement, and (3) multi-resolution progressive training. Our method achieves an optimal balance between quality and speed. On the FeTA dataset, M-Gaussian achieves 40.31 dB PSNR while being 14 times faster, representing the first successful adaptation of 3D Gaussian Splatting to multi-stack MRI reconstruction.
Figures & tables
Figure 1: Overview of the M-Gaussian framework. (a) The training pipeline integrates Gaussian rendering with a Neural Residual Field (NRF) refinement module. (b) Point cloud construction is performed via multi-stack registration and devoxelization to initialize the Gaussians. (c) The inference stage generates the final volume through Gaussian sampling and aggregation at the target resolution.
Figure 2: Comparison between original 3D Gaussian Splatting primitives and the proposed Magnetic Gaussian primitives. The original 3DGS utilizes view-dependent spherical harmonic coefficients for color representation, whereas M-Gaussian employs a single intensity value to model tissue-specific MRI signal properties, which significantly reduces memory overhead.
Methods
PSNR (dB) ↑
SSIM ↑
NCC ↑
NRMSE ↓
Runtime (min) ↓
FeTA Dataset
NiftyMIC [ 6 ]
36.08
0.9857
0.9932
0.0157
79.12
SVRTK [ 11 ]
34.64
0.9861
0.9916
0.0185
14.75
NeSVoR [ 17 ]
31.35
0.9588
0.9546
0.0414
31.75
M-Gaussian (Ours)
40.31
0.9936
0.9975
0.0096
5.63
FaBiAN Dataset
Table 1: Quantitative comparison with baseline slice-to-volume MRI reconstruction methods across three datasets. Metrics include PSNR, SSIM, NCC, and NRMSE for reconstruction quality, and runtime for computational efficiency. Best results are in bold , second-best are underlined .
Figure 3: Qualitative comparison of slice-to-volume MRI reconstruction methods. Each row shows results from a different dataset (FeTA, FaBiAN, HCP). The Input column displays one representative stack from the multi-stack acquisition. Our M-Gaussian method produces reconstructions with sharper anatomical boundaries and fewer artifacts compared to baseline methods.
Figure 4: Qualitative ablation results on Progressive resolution (P.R.) training and SSIM loss. Progressive resolution training stabilizes convergence, while the inclusion of SSIM loss significantly enhances the preservation of structural integrity and contrast. The effect is particularly significant on FeTA dataset.
Figure 5: Qualitative ablation results on Neural Residual Field (NRF). The NRF suppresses noise and refines high-frequency details, which is prominent on the HCP dataset.
Figure 6: Qualitative ablation results on Anisotropic Regularization (A.R.). The absence of A.R. leads to needle-like artifacts due to degenerate Gaussian geometries. These artifacts are effectively mitigated in the full model, which is most pronounced on the FaBiAN dataset.
Configuration
FeTA
FaBiAN
HCP
PSNR
SSIM
PSNR
SSIM
PSNR
SSIM
Full model
40.31
0.9936
32.26
0.9521
33.10
0.9776
w/o SSIM
32.24
0.9611
31.01
0.9388
32.56
0.9582
w/o SSIM & P.R.
31.07
0.9573
28.43
0.9272
31.36
0.9512
w/o NRF
39.11
0.9893
30.93
0.9387
31.96
0.9538
w/o A.R.
39.49
0.9902
30.02
0.9486
32.82
0.9606
Table 2: Ablation study quantifying the contribution of structural similarity loss (SSIM), progressive resolution training (P.R.), Neural Residual Field (NRF), and anisotropic regularization (A.R.).
Resolution
PSNR ↑
SSIM ↑
Time (min) ↓
503
30.27
0.9352
10.82
1503
31.31
0.9505
16.43
2503
31.50
0.9527
24.70
3503
31.76
0.9547
27.07
4003
31.63
0.9546
30.30
Table 3: Impact of Gaussian grid resolution on reconstruction fidelity and training time using the HCP dataset. The models were trained with fixed resolutions, excluding the effect of progressive training strategy.
Figure 10
Block Radius
PSNR ↑
SSIM ↑
Time (min) ↓
3
32.40
0.9733
7.62
4
32.67
0.9768
11.13
5
33.10
0.9776
17.28
6
32.77
0.9778
26.32
7
32.89
0.9780
34.24
Table 4: Quantitative assessment of reconstruction performance under different block radius settings. The results illustrate the trade-off between reconstruction quality and runtime.
Structure
Dice ↑
HD95 (mm) ↓
ASSD (mm) ↓
NiftyMIC
SVRTK
NeSVoR
M-Gaussian
NiftyMIC
SVRTK
NeSVoR
M-Gaussian
NiftyMIC
SVRTK
NeSVoR
M-Gaussian
External CSF
0.859
0.883
0.888
0.905
1.43
1.42
1.10
0.97
0.55
0.53
0.46
0.41
Grey Matter
0.832
0.816
0.843
0.846
0.82
0.85
0.68
0.66
0.37
0.38
0.34
0.32
White Matter
0.945
0.937
0.951
0.953
0.95
1.11
0.80
0.69
0.39
0.46
0.36
0.34
Ventricles
0.914
0.818
0.906
0.917
0.64
1.23
0.65
0.63
0.28
0.52
0.30
0.28
Cerebellum
0.924
0.934
0.941
0.931
1.12
0.94
0.87
1.05
0.46
0.40
0.36
0.42
Table 5: Quantitative evaluation of segmentation performance on the FeTA dataset. Metrics include Dice, HD95, and ASSD. Best results are bold , second-best are underlined .
Figure 9: Qualitative comparison of downstream segmentation results on the FeTA dataset. M-Gaussian reconstructions yield segmentation masks with the closest correspondence to ground truth, particularly for large-scale structures such as the cortical ribbon and ventricular boundaries.
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China